A Novel Non-interfering Arterial Blood Pressure Monitoring Device
Primary Purpose
Hypertension, Hypotension, Healthy
Status
Withdrawn
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
3M
ContiPressTM
Mobil-O-Graph
Sponsored by
About this trial
This is an interventional supportive care trial for Hypertension
Eligibility Criteria
Inclusion Criteria:
- At least 30% of the subjects must be males (n=29)
- At least 30% of the subjects must be female (n=29)
- Age ≥ 18 years old
- Limb size circumference ≥ 17 cm
- Blood pressure distribution:
- At least 25 % of the subjects should be hypertensive
- At least 5 % of the subjects should be hypotensive
Exclusion Criteria:
- Breached skin
- Acknowledged pregnancy
- Pacemaker
- Diagnosed cardiac arrhythmia (tachycardia, bradycardia, atrial/ventricular fibrillation)
Implanted metal in upper limb:
- Elbow prosthesis
- Shoulder prosthesis
- Metal screws
- Bone plates
- Metal chips
- Surgical clips
- Implantable Cardiac Defibrillator (ICD)
- Cardiac Resynchronization Therapy - Defibrillator (CRT-D)
- Premature ventricular contractions (PVC)
- Premature arterial contractions (PAC)
- Sensitivity or allergy towards adhesives
- Presence of an arterial-venous shunt
- Recent axillary node dissection
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Experimental
Arm Label
ContiPress vs. 3M
ContiPress vs. Mobil-O-Graph
Arm Description
ContiPress vs. 3M passive and during exercise
ContiPress vs. Mobil-O-Graph passive, then oscillometric passive, then oscillometric for 24 hrs every 15 mins.
Outcomes
Primary Outcome Measures
Accuracy of measurement
The reference measurements are compared with the measurements made by the investigational device
Secondary Outcome Measures
Skin irritation
After removal of each investigational device the skin is assessed. Also participants are instructed to report any skin irritation to investigator
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT01954446
Brief Title
A Novel Non-interfering Arterial Blood Pressure Monitoring Device
Official Title
A Novel Non-interfering Arterial Blood Pressure Monitoring Device
Study Type
Interventional
2. Study Status
Record Verification Date
September 2013
Overall Recruitment Status
Withdrawn
Why Stopped
The investigational devices need alterations before validation
Study Start Date
April 2013 (undefined)
Primary Completion Date
December 2013 (Anticipated)
Study Completion Date
December 2013 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Sense A/S
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
The primary purpose of this investigation is to validate the performance and safety of the Investigational Device (ID) against a validated and legally cleared device for measuring Blood Pressure (BP). The secondary purpose is to validate the performance of the ID over a period of 24 hours against a validated and legally cleared device for Ambulatory Blood Pressure Monitoring (ABPM).
Detailed Description
The clinical investigation is conducted as a controlled (subject as own control), prospective, randomised, comparative investigation in a population with a representative spread of BPs to ensure that the ID performs as good as current marketed and approved devices. The study will be conducted in compliance with the International Standard ANSI/AAMI/ISO 81060-2 - Non-invasive sphygmomanometers - Clinical validation of automated measurement type.
This clinical investigation will enrol up to 96 male and female subjects to ensure the recording of 85/35 evaluable datasets in accordance with the ANSI/AAMI/ISO standard [11]. All measurements will be paired and falls into 2 categories: Auscultatory measurements as gold standard reference, oscillometric measurements for clinical practise reference and further validation of ambulatory monitoring and pulse shape measurements.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Hypertension, Hypotension, Healthy
7. Study Design
Primary Purpose
Supportive Care
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
0 (Actual)
8. Arms, Groups, and Interventions
Arm Title
ContiPress vs. 3M
Arm Type
Experimental
Arm Description
ContiPress vs. 3M passive and during exercise
Arm Title
ContiPress vs. Mobil-O-Graph
Arm Type
Experimental
Arm Description
ContiPress vs. Mobil-O-Graph passive, then oscillometric passive, then oscillometric for 24 hrs every 15 mins.
Intervention Type
Device
Intervention Name(s)
3M
Intervention Description
Conventional measuring of BP
Intervention Type
Device
Intervention Name(s)
ContiPressTM
Intervention Description
New way of measuring BP - ContiPressTM
Investigational device
Intervention Type
Device
Intervention Name(s)
Mobil-O-Graph
Intervention Description
2 different devices for oscillometric measurement of BP
Primary Outcome Measure Information:
Title
Accuracy of measurement
Description
The reference measurements are compared with the measurements made by the investigational device
Time Frame
Up to 4 months
Secondary Outcome Measure Information:
Title
Skin irritation
Description
After removal of each investigational device the skin is assessed. Also participants are instructed to report any skin irritation to investigator
Time Frame
Up to 4 months
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
At least 30% of the subjects must be males (n=29)
At least 30% of the subjects must be female (n=29)
Age ≥ 18 years old
Limb size circumference ≥ 17 cm
Blood pressure distribution:
At least 25 % of the subjects should be hypertensive
At least 5 % of the subjects should be hypotensive
Exclusion Criteria:
Breached skin
Acknowledged pregnancy
Pacemaker
Diagnosed cardiac arrhythmia (tachycardia, bradycardia, atrial/ventricular fibrillation)
Implanted metal in upper limb:
Elbow prosthesis
Shoulder prosthesis
Metal screws
Bone plates
Metal chips
Surgical clips
Implantable Cardiac Defibrillator (ICD)
Cardiac Resynchronization Therapy - Defibrillator (CRT-D)
Premature ventricular contractions (PVC)
Premature arterial contractions (PAC)
Sensitivity or allergy towards adhesives
Presence of an arterial-venous shunt
Recent axillary node dissection
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Michael H Olsen, Prof. MD
Organizational Affiliation
Odense University Hospital
Official's Role
Principal Investigator
12. IPD Sharing Statement
Learn more about this trial
A Novel Non-interfering Arterial Blood Pressure Monitoring Device
We'll reach out to this number within 24 hrs