search
Back to results

Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function

Primary Purpose

Jaw, Edentulous

Status
Completed
Phase
Not Applicable
Locations
Canada
Study Type
Interventional
Intervention
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)
Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)
Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Sponsored by
Université de Montréal
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Jaw, Edentulous focused on measuring Dental Implants, Microtextured Fixture, Machined Collar

Eligibility Criteria

48 Years - 82 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • non-smoker
  • no temporomandibular joint (TMJ) disorder or facial pain
  • having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years

Exclusion Criteria:

  • refusal to sign informed consent documents

Sites / Locations

  • Université de Montréal

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

Active Comparator

Experimental

Experimental

Arm Label

Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)

Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)

Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)

Arm Description

Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site

Device placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites

Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites

Outcomes

Primary Outcome Measures

Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations

Secondary Outcome Measures

Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function
Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness). Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function
Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function
Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function
Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999). Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function
Absence (0) or presence (1) of purulent exudate on probing was evaluated. Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)

Full Information

First Posted
February 20, 2019
Last Updated
May 18, 2021
Sponsor
Université de Montréal
search

1. Study Identification

Unique Protocol Identification Number
NCT03862482
Brief Title
Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function
Official Title
Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses
Study Type
Interventional

2. Study Status

Record Verification Date
May 2021
Overall Recruitment Status
Completed
Study Start Date
June 3, 2019 (Actual)
Primary Completion Date
August 16, 2019 (Actual)
Study Completion Date
December 31, 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Université de Montréal

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
Yes
Data Monitoring Committee
No

5. Study Description

Brief Summary
Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. 1987; Albrektsson, T., et al., 1981; Albrektsson, T., et al., 1986; Brånemark, P-I. , 1983; Brånemark P-I. 1987), newer implant designs were introduced that could enhance fusion of the implant to jaw bones, and better resist functional forces. One such implant, Screw-Vent®, has a fixture macro structure very similar to that of the Brånemark® implant. However, its fixture surface was acid etched (1-3µm) which could enhance osseointegration, and it has a longer, narrower machined internal-hex, friction-fit collar that could better resist functional forces.These characteristics should lead to less bone loss (Niznick, G. A., 1989). However, one clinical study (De Bruyen, et al., 1992) reported greater short-term bone loss with this implant compared to the Brånemark® implant, possibly due to its longer machined collar, and advocated long-term clinical studies. Therefore, this prospective within-subject clinical trial was undertaken in 1993 to first compare the Brånemark® implant with another implant, Swede-Vent®, a copy of the Brånemark® macro structure except for its fixture surface that was identically micro textured as that of Screw-Vent® by the same manufacturer. The effect on bone healing could then be compared between Brånemark®'s machined and Swede-Vent®'s micro textured fixture surfaces in the short- and long-terms. Since Screw-Vent®'s fixture surface was identically micro textured as that of Swede-Vent®, the investigators could then evaluate and compare the effects on bone healing of Screw-Vent®'s longer, narrower, internal-connection machined collar to the identical shorter, wider, external-connection machined collars of the Swede-Vent® and Brånemark® implants. All three two-part, platform-matched, parallel-wall implants were made of commercially pure titanium, had a very similar fixture macro design, were approved by the Food and Drug Administration (USA) and Health and Welfare Canada, and were commercially available in North America. Brånemark® and Screw-Vent® implants are still available, but the Swede-Vent® implant is not.
Detailed Description
Therefore, between 1993 and 1996, 58 of 60 eligible participants had been recruited into a prospective, randomized clinical trial. This trial had been peer reviewed, had received ethical approval, and had taken place at the Université de Montréal's Faculty of Dental Medicine and its affiliated hospital dental department. Follow-up documentation occurred at one year, two years, and 15 to 20 years following prostheses attachment (ClinicalTrials Identification Number NCT01641198), and the results were published (Camarda, et al., 2018). The present study reports on data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up (ClinicalTrials Identification Number NCT03862482), focusing specifically on the evaluation and comparison of the effects on peri-implant healing and functional osseointegration of the two different machined collar designs. That is to say, the identical shorter, wider, external-connection Brånemark® and Swede-Vent® collars versus the longer, narrower, internal-connection Screw-Vent® collar. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled into this study. All study procedures were performed in accordance with the Helsinki Declaration and its later amendments, and all participants signed informed consent documents prior to inclusion into this study.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Jaw, Edentulous
Keywords
Dental Implants, Microtextured Fixture, Machined Collar

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
ParticipantCare ProviderInvestigator
Masking Description
For the initial study, a statistician had prepared a sampling design that included three configuration diagrams. Each diagram identified five implants of the three types, and showed how one of each type was to be placed in a cyclical, side-by-side, rotating fashion at five sites between mental foramena. Allocation concealment by the project coordinator then allowed 20 participants to receive Configuration 1, 19 had Configuration 2, and 19 had Configuration 3. Configuration diagram (but not number) was stored inside each chart, and only shown to the operating team at the time of surgery. The present study is a continuation of this clinical trial, including data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled in this study. Eight participants (40 implants) received Configuration 1, 8 (40 implants) had Configuration 2, and 6 (30 implants) had Configuration 3.
Allocation
Randomized
Enrollment
22 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)
Arm Type
Active Comparator
Arm Description
Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site
Arm Title
Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)
Arm Type
Experimental
Arm Description
Device placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites
Arm Title
Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Arm Type
Experimental
Arm Description
Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites
Intervention Type
Device
Intervention Name(s)
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)
Intervention Description
Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis)
Intervention Type
Device
Intervention Name(s)
Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)
Intervention Description
Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial)
Intervention Type
Device
Intervention Name(s)
Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Intervention Description
Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal)
Primary Outcome Measure Information:
Title
Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations
Description
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Secondary Outcome Measure Information:
Title
Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function
Description
Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness). Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Title
Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function
Description
Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Title
Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function
Description
Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Title
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function
Description
Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999). Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Title
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function
Description
Absence (0) or presence (1) of purulent exudate on probing was evaluated. Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Other Pre-specified Outcome Measures:
Title
Comparison of Two Measurement Systems Used to Evaluate Peri-implant Bone Healing After 25 Years of Function
Description
Conventional peri-apical radiology and phosphor-plate digital technology (Digora System™, Digora OptimeTM, Sporedex Dental Co., Tuusula, Finland) were used with the standardized equipment to take peri-apical radiographs on 95 implant/abutment units (Camarda, et al., 2018; Bhaskaran, et al., 2005). Following calibration, the distance between the first-bone-to-implant-contact-point and the crestal-microgap (fBIC-MG) was measured (mm) at the mesial and distal aspects of each implant/abutment unit after 25 years of function. Values (Mean ± SE) fBIC-MG were recorded for each of the two measurement systems. ICC (Intraclass Correlation Coefficient, two-way, mixed effect model) and Bland-Altman Limits of agreement (Bland & Altman, 1986) were used to evaluate the level of agreement between the two systems
Time Frame
After 25 years (24.6 ± 0.19 years, mean ± SE) of function

10. Eligibility

Sex
All
Minimum Age & Unit of Time
48 Years
Maximum Age & Unit of Time
82 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: non-smoker no temporomandibular joint (TMJ) disorder or facial pain having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years Exclusion Criteria: refusal to sign informed consent documents
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Aldo J Camarda, DDS, MSc
Organizational Affiliation
Université de Montréal
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Robert Durand, DMD, MSc
Organizational Affiliation
Université de Montréal
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Marwa Benkarim
Organizational Affiliation
Université de Montréal
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Pierre Rompré, MSc
Organizational Affiliation
Université de Montréal
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Geneviève Guertin, DMD, MSc
Organizational Affiliation
Université de Montréal
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Hugo Ciaburro, DMD, MSc
Organizational Affiliation
Université de Montréal
Official's Role
Study Director
Facility Information:
Facility Name
Université de Montréal
City
Montreal
State/Province
Quebec
ZIP/Postal Code
H3C 3J7
Country
Canada

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
Citation
Adell, R. (1987). Long-term treatment results. In: Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 175-285). Quintessence Publishing Co. Inc.
Results Reference
background
PubMed Identifier
7246093
Citation
Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776.
Results Reference
background
PubMed Identifier
3527955
Citation
Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. No abstract available.
Results Reference
background
PubMed Identifier
16104978
Citation
Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K. A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J. 2005 Sep;38(9):645-52. doi: 10.1111/j.1365-2591.2005.00998.x.
Results Reference
background
PubMed Identifier
2868172
Citation
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
Results Reference
background
PubMed Identifier
6352924
Citation
Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410. doi: 10.1016/s0022-3913(83)80101-2. No abstract available.
Results Reference
background
Citation
Brånemark P-I. (1987). Introduction to osseointegration. In Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 11-76). Quintessence Publishing Co. Inc.
Results Reference
background
PubMed Identifier
1420725
Citation
De Bruyn H, Collaert B, Linden U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Branemark fixtures, installed in a periodontal clinic. Clin Oral Implants Res. 1992 Mar;3(1):32-41. doi: 10.1034/j.1600-0501.1992.030106.x.
Results Reference
background
PubMed Identifier
10803118
Citation
Galgut P. A comparison of different indices used in the clinical assessment of plaque and gingival bleeding. Clin Oral Investig. 1999 Jun;3(2):96-9. doi: 10.1007/s007840050085.
Results Reference
background
Citation
Niznick, G. A. (1989). Open letters no. 1 and no. 2 to the dental profession, Core-Vent Corporation Newsletter and manufacturer's product description. Encino, California USA.
Results Reference
background
PubMed Identifier
33314332
Citation
Camarda AJ, Durand R, Benkarim M, Rompre PH, Guertin G, Ciaburro H. Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years. Clin Oral Implants Res. 2021 Mar;32(3):285-296. doi: 10.1111/clr.13699. Epub 2021 Jan 25.
Results Reference
result
PubMed Identifier
30202836
Citation
Camarda AJ, Milot P, Ciaburro H, Rompre PH, Sallaleh I, Do CMA. Long-term randomized clinical trial evaluating the effects of fixture surface acid-etching and machined collar design on bone healing. Quintessence Int. 2018;49(9):733-743. doi: 10.3290/j.qi.a41013.
Results Reference
result

Learn more about this trial

Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function

We'll reach out to this number within 24 hrs