search
Back to results

MATTERS Study - Mistral Percutaneous Tricuspid Valve Repair FIM Study

Primary Purpose

Tricuspid Valve Regurgitation

Status
Completed
Phase
Not Applicable
Locations
Israel
Study Type
Interventional
Intervention
Mistral implantation
Sponsored by
Mitralix
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Tricuspid Valve Regurgitation

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Subject has given signed study Informed Consent for participation prior to procedure.
  • Subject is ≥ 18 years of age or legal age in host country
  • Subject is willing and able to comply with all required follow-up evaluations
  • Genders eligible for the study: Both genders
  • Subject has TR of grade 3+ or more
  • Subject has left ventricular ejection fraction (LVEF) >20 %
  • Subject is of functional class 2 or more (NYHA)
  • The subject is high risk to undergo TV surgery as assessed and consented by a cardiac surgeon and an interventional cardiologist at the site (center heart team), and according to ESC/EACTS guidelines on the management of valvular heart disease.
  • Patients with Jugular and/or Femoral veins enabling catheterization with 12Fr catheters
  • Life expectancy ≥ 1 year

Exclusion Criteria:

  • Tricuspid Stenosis >mild
  • Tricuspid Subvalvular calcification or calcification of the chordae.
  • Subject has a history of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 3 months.
  • Subject has a history of a myocardial infarction (MI) in the past 3 months
  • Subject has had a percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 7 days of the index procedure
  • Subject has a history of, or has active endocarditis
  • Subject has echocardiographic evidence of intra-cardiac mass, thrombus, vegetation or soft-mobile deposits
  • Subject is in acute pulmonary edema.
  • Subject has hemodynamic instability requiring inotropic or mechanical support.
  • Subject has a known hypersensitivity or contraindication to anticoagulant or antiplatelet medication
  • Subject has renal insufficiency as evidenced by a serum Creatinine > 3.0mg/dL.
  • Subject has ongoing infection or sepsis
  • Subject has blood dyscrasias (leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy)
  • Subject has an active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 3 months prior to the index procedure
  • Subject requires emergency surgery for any reason
  • Subject has a known allergy to Nitinol alloys, 316L\304 stainless steel.
  • Pregnant or lactating women.
  • Patients being dependent upon the sponsor or upon the investigator or upon the investigational site.
  • Subject has a known contrast media allergy
  • Presence of high degree atrio-ventricular block (2nd or 3rd degree A-V block), or the presence of tri-fascicular block
  • According to investigator on site the patient is suffering from a severe end stage disease (e.g. malignancy, severe pulmonary disease, liver disease, renal failure) and has a life expectancy of less than 1 year.
  • Contraindication for treatment with dual antiplatelet therapy for at least 3 months
  • Contraindication for TEE including trans-gastric views.

Sites / Locations

  • Haddassah
  • The Chain Sheba Medical Center at Tel HaShomer
  • Tel Aviv Sourasky Medical Center

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Mistral

Arm Description

The Mistral is an investigational device intended for percutaneous trans-catheter repair in high risk for surgery individuals suffering from functional Tricuspid Regurgitation (TR). The device system is to be used only in accordance with the approved Investigational Plan on subjects who have signed an informed consent form. Device use is limited to the approved study investigators.

Outcomes

Primary Outcome Measures

Safety: Acute safety. Rate of device related SAE
including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event
Safety: Acute safety. Rate of device related SAE
including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event
Performance: Mistral Implantation rate of technical success
defined as successful device implantation with grasped chords from at least two leaflets

Secondary Outcome Measures

Safety: Rate of device related SAE
Safety: Rate of device related SAE
Safety: Rate of device related SAE
Safety: Rate of device related SAE
Relevant only for patients 11-20
Effectiveness: TR Grade reduction
Effectiveness: TR Grade reduction
Effectiveness: TR Grade reduction
Effectiveness: NYHA class (categorization of heart failure extent)
Effectiveness: 6MWT distance
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Effectiveness: TR Grade reduction
Effectiveness: NYHA class (categorization of heart failure extent)
Effectiveness: 6MWT distance
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Effectiveness: TR Grade reduction
Effectiveness: TR Grade reduction
Relevant only for patients 11-20
Effectiveness: TR Grade reduction
Relevant only for patients 11-20
Effectiveness: NYHA class (categorization of heart failure extent)
Effectiveness: NYHA class (categorization of heart failure extent)
Relevant only for patients 11-20
Effectiveness: NYHA class (categorization of heart failure extent)
Relevant only for patients 11-20
Effectiveness: 6MWT distance
Effectiveness: 6MWT distance
Relevant only for patients 11-20
Effectiveness: 6MWT distance
Relevant only for patients 11-20
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Relevant only for patients 11-20
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Relevant only for patients 11-20

Full Information

First Posted
April 13, 2017
Last Updated
October 17, 2023
Sponsor
Mitralix
search

1. Study Identification

Unique Protocol Identification Number
NCT04071652
Brief Title
MATTERS Study - Mistral Percutaneous Tricuspid Valve Repair FIM Study
Official Title
MATTERS Study - Mistral Percutaneous Tricuspid Valve Repair FIM Study
Study Type
Interventional

2. Study Status

Record Verification Date
October 2023
Overall Recruitment Status
Completed
Study Start Date
August 8, 2017 (Actual)
Primary Completion Date
October 1, 2020 (Actual)
Study Completion Date
February 28, 2023 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Mitralix

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No

5. Study Description

Brief Summary
The Mistral is an investigational device intended for percutaneous trans-catheter repair in high risk for surgery individuals suffering from functional Tricuspid Regurgitation (TR). The device system is to be used only in accordance with the approved Investigational Plan on subjects who have signed an informed consent form. Device use is limited to the approved study investigators.
Detailed Description
The study is designed to clinically demonstrate device acute safety and technical performance (Primary Endpoints) along with longer FU device safety and effectiveness evaluation (Secondary Endpoint). The main objectives of the study are : Evaluate the Acute safety of the implanted Mistral device post procedure and at 30 day follow up period. Evaluate the long term Safety of the device. Demonstrate effectiveness of the Mistral device in reducing TR. Primary endpoints: Safety: Acute safety. Rate of device related SAE including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event. At discharge and 30 days. Performance: Mistral Implantation rate of technical success (defined as successful device implantation with grasped chords from at least two leaflets.). Secondary endpoints: Safety: Safety at 3, 6 and 12 months. Rate of device related SAEs at 3, 6 and 12 months. Effectiveness: TR reduction post-procedure, at discharge and 30 days, 3 and 6 months. Improved NYHA class, 6MWTdistance and KCCQ (quality of life) at 30 days, 3 and 6 months. Relevant only for patients 11-20: Safety: Safety at 3, 6, 12 and 24 months. Rate of device related SAEs at 3, 6, 12 and 24 months. Effectiveness: TR reduction post-procedure, at discharge and 30 days, 3, 6, 12 and 24 months. Improved NYHA class, 6MWT distance and KCCQ (quality of Life) at 30 days, 3, 6, 12 and 24 months.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Tricuspid Valve Regurgitation

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
17 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Mistral
Arm Type
Experimental
Arm Description
The Mistral is an investigational device intended for percutaneous trans-catheter repair in high risk for surgery individuals suffering from functional Tricuspid Regurgitation (TR). The device system is to be used only in accordance with the approved Investigational Plan on subjects who have signed an informed consent form. Device use is limited to the approved study investigators.
Intervention Type
Device
Intervention Name(s)
Mistral implantation
Intervention Description
Mistral implant is implanted in the Tricuspid valve
Primary Outcome Measure Information:
Title
Safety: Acute safety. Rate of device related SAE
Description
including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event
Time Frame
Until hospital discharge - up to 5 days post procedure day
Title
Safety: Acute safety. Rate of device related SAE
Description
including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event
Time Frame
At 30 days post procedure
Title
Performance: Mistral Implantation rate of technical success
Description
defined as successful device implantation with grasped chords from at least two leaflets
Time Frame
Procedure
Secondary Outcome Measure Information:
Title
Safety: Rate of device related SAE
Time Frame
at 3 months post procedure
Title
Safety: Rate of device related SAE
Time Frame
at 6 months post procedure
Title
Safety: Rate of device related SAE
Time Frame
at 12 months post procedure
Title
Safety: Rate of device related SAE
Description
Relevant only for patients 11-20
Time Frame
at 24 months post procedure
Title
Effectiveness: TR Grade reduction
Time Frame
post procedure (1 hour after implant device has been implanted)
Title
Effectiveness: TR Grade reduction
Time Frame
Until hospital discharge - up to 5 days post procedure day
Title
Effectiveness: TR Grade reduction
Time Frame
at 30 days post procedure
Title
Effectiveness: NYHA class (categorization of heart failure extent)
Time Frame
at 30 days post procedure
Title
Effectiveness: 6MWT distance
Time Frame
at 30 days post procedure
Title
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Time Frame
at 30 days post procedure
Title
Effectiveness: TR Grade reduction
Time Frame
at 3 months post procedure
Title
Effectiveness: NYHA class (categorization of heart failure extent)
Time Frame
at 3 months post procedure
Title
Effectiveness: 6MWT distance
Time Frame
at 3 months post procedure
Title
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Time Frame
at 3 months post procedure
Title
Effectiveness: TR Grade reduction
Time Frame
at 6 months post procedure
Title
Effectiveness: TR Grade reduction
Description
Relevant only for patients 11-20
Time Frame
at 12 months post procedure
Title
Effectiveness: TR Grade reduction
Description
Relevant only for patients 11-20
Time Frame
at 24 months post procedure
Title
Effectiveness: NYHA class (categorization of heart failure extent)
Time Frame
at 6 months post procedure
Title
Effectiveness: NYHA class (categorization of heart failure extent)
Description
Relevant only for patients 11-20
Time Frame
at 12 months post procedure
Title
Effectiveness: NYHA class (categorization of heart failure extent)
Description
Relevant only for patients 11-20
Time Frame
at 24 months post procedure
Title
Effectiveness: 6MWT distance
Time Frame
at 6 months post procedure
Title
Effectiveness: 6MWT distance
Description
Relevant only for patients 11-20
Time Frame
at 12 months post procedure
Title
Effectiveness: 6MWT distance
Description
Relevant only for patients 11-20
Time Frame
at 24 months post procedure
Title
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Time Frame
at 6 months post procedure
Title
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Description
Relevant only for patients 11-20
Time Frame
at 12 months post procedure
Title
Effectiveness: KCCQ (Kansas City Cardiomyopathy Questionnaire)
Description
Relevant only for patients 11-20
Time Frame
at 24 months post procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Subject has given signed study Informed Consent for participation prior to procedure. Subject is ≥ 18 years of age or legal age in host country Subject is willing and able to comply with all required follow-up evaluations Genders eligible for the study: Both genders Subject has TR of grade 3+ or more Subject has left ventricular ejection fraction (LVEF) >20 % Subject is of functional class 2 or more (NYHA) The subject is high risk to undergo TV surgery as assessed and consented by a cardiac surgeon and an interventional cardiologist at the site (center heart team), and according to ESC/EACTS guidelines on the management of valvular heart disease. Patients with Jugular and/or Femoral veins enabling catheterization with 12Fr catheters Life expectancy ≥ 1 year Exclusion Criteria: Tricuspid Stenosis >mild Tricuspid Subvalvular calcification or calcification of the chordae. Subject has a history of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 3 months. Subject has a history of a myocardial infarction (MI) in the past 3 months Subject has had a percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 7 days of the index procedure Subject has a history of, or has active endocarditis Subject has echocardiographic evidence of intra-cardiac mass, thrombus, vegetation or soft-mobile deposits Subject is in acute pulmonary edema. Subject has hemodynamic instability requiring inotropic or mechanical support. Subject has a known hypersensitivity or contraindication to anticoagulant or antiplatelet medication Subject has renal insufficiency as evidenced by a serum Creatinine > 3.0mg/dL. Subject has ongoing infection or sepsis Subject has blood dyscrasias (leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy) Subject has an active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 3 months prior to the index procedure Subject requires emergency surgery for any reason Subject has a known allergy to Nitinol alloys, 316L\304 stainless steel. Pregnant or lactating women. Patients being dependent upon the sponsor or upon the investigator or upon the investigational site. Subject has a known contrast media allergy Presence of high degree atrio-ventricular block (2nd or 3rd degree A-V block), or the presence of tri-fascicular block According to investigator on site the patient is suffering from a severe end stage disease (e.g. malignancy, severe pulmonary disease, liver disease, renal failure) and has a life expectancy of less than 1 year. Contraindication for treatment with dual antiplatelet therapy for at least 3 months Contraindication for TEE including trans-gastric views.
Facility Information:
Facility Name
Haddassah
City
Jerusalem
State/Province
Kiryat Hadassah
ZIP/Postal Code
91120
Country
Israel
Facility Name
The Chain Sheba Medical Center at Tel HaShomer
City
Ramat Gan
ZIP/Postal Code
52621
Country
Israel
Facility Name
Tel Aviv Sourasky Medical Center
City
Tel Aviv
ZIP/Postal Code
6423906
Country
Israel

12. IPD Sharing Statement

Learn more about this trial

MATTERS Study - Mistral Percutaneous Tricuspid Valve Repair FIM Study

We'll reach out to this number within 24 hrs