search
Back to results

Outcome Following Semitubular Plate vs. Polyaxial Locking Plates

Primary Purpose

Ankle Fractures

Status
Completed
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
ORIF non-locking
ORIF locking
Sponsored by
Technical University of Munich
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Ankle Fractures

Eligibility Criteria

18 Years - 65 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • age between 18 and 65 years
  • Fracture of the distal fibula (AO 44 B1.1, B1.2, B1.3)
  • Written informed consent

Exclusion Criteria:

  • Pregnancy
  • mental disorders
  • comprehensive legal support.
  • pathological and/or osteoporotic fracture
  • open fracture

Sites / Locations

    Arms of the Study

    Arm 1

    Arm 2

    Arm Type

    Active Comparator

    Active Comparator

    Arm Label

    1/3 tubular plate

    Active ankle plate

    Arm Description

    Standard care according to AO guidelines using the Implant "1/3 tubular plate"

    Actual care using the new implant using the Implant "Active ankle plate"

    Outcomes

    Primary Outcome Measures

    Ankle function
    Clinical objective ankle function assessed by Olerud and Molander ankle score (OMAS)

    Secondary Outcome Measures

    Ankle function
    Clinical objective ankle function assessed by Foot and Ankle outcome score (FAOS)

    Full Information

    First Posted
    April 20, 2020
    Last Updated
    May 1, 2020
    Sponsor
    Technical University of Munich
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT04370561
    Brief Title
    Outcome Following Semitubular Plate vs. Polyaxial Locking Plates
    Official Title
    a Prospective Randomized Study on the Outcome Following Osteosynthesis of Distal Fibula Fracture Using Semitubular Plate in AO Technique vs. Polyaxial Locking Plates
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    May 2020
    Overall Recruitment Status
    Completed
    Study Start Date
    January 1, 2016 (Actual)
    Primary Completion Date
    January 1, 2018 (Actual)
    Study Completion Date
    January 1, 2019 (Actual)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Principal Investigator
    Name of the Sponsor
    Technical University of Munich

    4. Oversight

    Studies a U.S. FDA-regulated Drug Product
    No
    Studies a U.S. FDA-regulated Device Product
    No
    Product Manufactured in and Exported from the U.S.
    No
    Data Monitoring Committee
    No

    5. Study Description

    Brief Summary
    In this prospective study, all patients with distal fibula fractures (AO 44 B1.1, B1.2, B1.3), with indication for surgery were included. Patients were randomized to either the DePuy Synthes® one-third semitubular plate (Group I) or NEWCLIP TECHNICS, Active Ankle® polyaxial locking plate (Group II). In Group II early weight bearing was allowed after two weeks postoperatively. Primary outcome parameter was function of the ankle joint, assessed by the Olerud and Molander ankle score (OMAS), Foot and Ankle outcome score (FAOS) and Karlsson and Peterson Scoring System for Ankle function (KPSS). Secondary outcome parameter were postoperative complications. Superficial wound infection, delayed wound healing, mechanically prominent implant, skin irritations were considered as minor and deep wound infection, material loosening, loss of reduction were regarded as major complications requiring revision surgery. Clinical and radiological follow-up were performed 6 and 12 weeks, 6 months and 1 year postoperatively.

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Ankle Fractures

    7. Study Design

    Primary Purpose
    Treatment
    Study Phase
    Not Applicable
    Interventional Study Model
    Parallel Assignment
    Masking
    None (Open Label)
    Allocation
    Randomized
    Enrollment
    45 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    1/3 tubular plate
    Arm Type
    Active Comparator
    Arm Description
    Standard care according to AO guidelines using the Implant "1/3 tubular plate"
    Arm Title
    Active ankle plate
    Arm Type
    Active Comparator
    Arm Description
    Actual care using the new implant using the Implant "Active ankle plate"
    Intervention Type
    Procedure
    Intervention Name(s)
    ORIF non-locking
    Intervention Description
    Open reduction and internal fixation using 1/3 tubular plate
    Intervention Type
    Procedure
    Intervention Name(s)
    ORIF locking
    Intervention Description
    Open reduction and internal fixation using active ankle polyaxial locking plate
    Primary Outcome Measure Information:
    Title
    Ankle function
    Description
    Clinical objective ankle function assessed by Olerud and Molander ankle score (OMAS)
    Time Frame
    12 month
    Secondary Outcome Measure Information:
    Title
    Ankle function
    Description
    Clinical objective ankle function assessed by Foot and Ankle outcome score (FAOS)
    Time Frame
    12 month

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    18 Years
    Maximum Age & Unit of Time
    65 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: age between 18 and 65 years Fracture of the distal fibula (AO 44 B1.1, B1.2, B1.3) Written informed consent Exclusion Criteria: Pregnancy mental disorders comprehensive legal support. pathological and/or osteoporotic fracture open fracture
    Overall Study Officials:
    First Name & Middle Initial & Last Name & Degree
    Chlodwig Kirchhoff, MD
    Organizational Affiliation
    Klinik für Unfallchirurgie, Klinikum rechts der Isar, TU München
    Official's Role
    Principal Investigator

    12. IPD Sharing Statement

    Plan to Share IPD
    No
    Citations:
    PubMed Identifier
    33563235
    Citation
    Zyskowski M, Wurm M, Greve F, Pesch S, von Matthey F, Pfluger P, Cronlein M, Biberthaler P, Kirchhoff C. Is early full weight bearing safe following locking plate ORIF of distal fibula fractures? BMC Musculoskelet Disord. 2021 Feb 9;22(1):159. doi: 10.1186/s12891-021-04009-x.
    Results Reference
    derived

    Learn more about this trial

    Outcome Following Semitubular Plate vs. Polyaxial Locking Plates

    We'll reach out to this number within 24 hrs