search
Back to results

Diagnosis of Respiratory Viruses in Children With Rhinoswab Junior

Primary Purpose

SARS CoV 2 Infection, COVID-19

Status
Completed
Phase
Not Applicable
Locations
Australia
Study Type
Interventional
Intervention
Rhinoswab Junior
Combined nose and throat swab
Saliva swab
Abbott Panbio™ COVID-19 antigen self-test kit
Sponsored by
Murdoch Childrens Research Institute
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for SARS CoV 2 Infection focused on measuring Rhinoswab Junior

Eligibility Criteria

1 Month - 18 Years (Child, Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • Symptomatic and requiring a COVID-19 test at RCH or confirmed/suspected COVID-19 at home.
  • Aged between 1 month -18 years old.
  • Parent/guardian present.
  • Parents/self are able to provide consent.

Exclusion Criteria:

  • < 1 month or >18 years old.
  • Recent head or neck surgery
  • Inability (e.g. non-English speaking and if no interpreter is available) or unwillingness to consent

Sites / Locations

  • Shidan Tosif

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm 4

Arm Type

Experimental

Experimental

Experimental

Experimental

Arm Label

Arm 1 - Clinician Collected/supervised Rhinoswab first, then CTDN swab

Arm 2 - Clinician Collected/supervised CTDN swab first, then Rhinoswab

Arm 3 - Self-collected Rhinoswab, saliva swab, CTDN

Arm 4 - Self-collected RAT, saliva, CTDN

Arm Description

Rhinoswab test administered and immediately followed by CTDN. Rhinoswab swab tested on respiratory panel vs CTDN swab tested on respiratory panel (standard of care).

CTDN test administered and immediately followed by Rhinoswab. CTDN swab tested on respiratory panel (standard of care) vs Rhinoswab swab tested on respiratory panel.

In children 5-18 years, the child/parent/guardian collects the three samples, in order of patient/parent preference. All samples will be tested on the SARS-CoV-2 laboratory panel (Allplex™ SARS-CoV-2 Assay - Seegene Inc)

In children 1 month -5 years, the child/parent/guardian collects the three samples, in order of patient/parent preference. Saliva and CTDN samples will be tested on the SARS-CoV-2 laboratory panel (Allplex™ SARS-CoV-2 Assay - Seegene Inc), RAT test kit will be Abbott PanBio

Outcomes

Primary Outcome Measures

Sensitivity of Rhinoswab compared with CTDN for 13 viruses on standard respiratory panel (Clinician collected/supervised)
The results (detected/not detected) on all 13 viruses on the standard respiratory panel from both the Rhinoswab and the standard swabs will be obtained, and the sensitivity of the Rhinoswab compared to the CTDN determined. Sensitivity is calculated only in the participants who tested positive for the respective virus using the CTDN swab and is calculated as the proportion patients who tested positive on the Rhinoswab among those who tested positive on the CTDN swab. 95% confidence intervals will be calculated.
Specificity of Rhinoswab compared with CTDN for 13 viruses on standard respiratory panel (Clinician collected/supervised)
The results (detected/not detected) on all 13 viruses on the standard respiratory panel from both the Rhinoswab and the standard swabs will be obtained, and the specificity of the Rhinoswab compared to the CTDN determined. Specificity is calculated only in participants who tested negative for respiratory viruses and is calculated as the proportion patients who tested negative on Rhinoswab among those who tested negative on CTDN swab. 95% confidence intervals will be calculated.

Secondary Outcome Measures

Ct-Value of respiratory viruses on Rhinoswab compared with Ct-value of respiratory viruses on CTDN (Clinician-Collected/Supervised)
Median Ct-Value of respiratory viruses on Rhinoswab compared with Ct-value of respiratory viruses on CTDN for each detection will be compared. The CT value for the undetected sample will be set at the maximum number of cycles performed in the laboratory (CT value maximum of 38.73). If the upper limit of the confidence interval is more than 3 Ct-value, the two swabs will be regarded as non-inferior.
Swab Preference Assessment (Clinician-Collected/Supervised )
The preferability for the Rhinoswab, compared to the standard sample for respiratory virus testing is determined, using the Likert scale or picture-based chart for standardised responses. Descriptive analyses will be used to describe child/parent/research preferences. A) Child/parent/research nurse will be asked to rate comfort for each swab: Extremely Comfortable 1 to Extremely Uncomfortable 5 B) What is your preference for future testing between CTDN and Rhinoswab? C) Which swab was better CTDN vs Rhinoswab?
Median Ct-value of SARS-CoV-2 on Rhinoswab vs saliva vs CTDN (Self-collected)
Median Ct-Value of SARS-CoV-2 on Rhinoswab, saliva and CTDN will be compared. The CT value for the undetected sample will be set at the maximum number of cycles performed in the laboratory (CT value maximum of 38.73). If the upper limit of the 95% confidence interval for the median difference is less than 3 CT, the Rhinoswab will be regarded as non-inferior.
Sensitivity of Rhinoswab compared with CTDN for SARS-CoV-2 (Self-collected)
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using the CTDN swab and is calculated as the proportion patients who tested positive on the Rhinoswab among those who tested positive on the CTDN swab.
Specificity of Rhinoswab compared with CTDN for SARS-CoV-2 (Self-collected)
Specificity is calculated only in participants who tested negative for SARS-CoV-2and is calculated as the proportion patients who tested negative on Rhinoswab among those who tested negative on CTDN swab.
Comparison of RAT test (detected/not detected) to Ct-values for saliva and standard CTDN for SARS-CoV-2 only (Self-collected)
The SARS-CoV-2 results (detected/not detected) from the RAT test will be compared with Ct-values from saliva and standard CTDN swabs.
Sensitivity of RAT compared with saliva for SARS-CoV-2 only (Self-collected)
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using saliva and is calculated as the proportion patients who tested positive on RAT among those who tested positive on saliva.
Sensitivity of RAT compared to standard CTDN for SARS-CoV-2 only (Self-collected)
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using the CTDN swab and is calculated as the proportion patients who tested positive on RAT among those who tested positive on CTDN swab.
Laboratory handling assessment
At the end of the study, the laboratory staff will be asked: A) Rate the handling experience of Rhinoswab vs CTDN using a Likert scale: Rhinoswab was easier to handle 1 to Rhinoswab was harder to handle 3 B) Was there a difference in processing the Rhinoswab versus the combined throat and deep nasal swab?: Rhinoswab was easier to process/There was no difference in processing/Rhinoswab was harder to process C) How did the Rhinoswab impact the workflow or lab efficiency compared to the standard combined throat and deep nasal swab? 1 Very easy and no impact on workflow or lab efficiency to 5 Very difficult and many complications on workflow or lab efficiency D) What benefits or challenges, did you observe when working with Rhinoswab in the lab? (Freetext)

Full Information

First Posted
August 26, 2021
Last Updated
February 6, 2023
Sponsor
Murdoch Childrens Research Institute
Collaborators
Rhinomed Pty Ltd
search

1. Study Identification

Unique Protocol Identification Number
NCT05043623
Brief Title
Diagnosis of Respiratory Viruses in Children With Rhinoswab Junior
Official Title
Diagnosis of Respiratory Viruses in Children With Rhinoswab Junior
Study Type
Interventional

2. Study Status

Record Verification Date
February 2023
Overall Recruitment Status
Completed
Study Start Date
August 26, 2021 (Actual)
Primary Completion Date
January 26, 2022 (Actual)
Study Completion Date
August 28, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Murdoch Childrens Research Institute
Collaborators
Rhinomed Pty Ltd

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
A study to investigate Rhinoswab as an alternative method to combined throat and deep nasal (CTDN) swab for respiratory sample collection in children who present to the Royal Children's Hospital (RCH) for viral testing. Children and their parent/guardian will answer a short survey about their preferences. Laboratory staff will answer a short survey about handling the different samples.
Detailed Description
The microbiological test of choice for detection of respiratory viruses is a reverse transcription polymerase chain reaction (RT-PCR). The test is reported as "detected" or "not-detected" to the clinician. The Ct-value is a microbiological analysis that represents the number of amplification cycles required for a target gene to exceed a threshold level, to determine a negative or positive result and is interpreted to detect respiratory viruses. The Ct-value is used to measure viral load. SARS-CoV-2, the virus that causes COVID-19, is a respiratory virus of specific interest. SARS-CoV-2 is detected in the upper respiratory tract. National guidelines for diagnosing COVID-19 in Australia require a combined throat and deep nasal swab (CTDN). No other testing options are routinely recommended in Australia. However, research and international guidelines recommend nasal swabs alone for SARS-CoV-2 detection. The Center for Disease Control and Prevention (USA) currently recommend the use of an anterior nasal swab alone as a method for detection of SARS-CoV-2. A recent systematic review suggested nasal swabs are a clinically acceptable alternative specimen collection methods. In addition to satisfactory diagnostic performance, nasal swabs are potentially less invasive, and can be self-collected. Research at the Melbourne Children's Campus has identified that the CTDN or nasopharyngeal swab, are uncomfortable and distressing for children. The fear of the test is a barrier for presentation to a health service for a SARS-CoV-2 test. Parental and child reluctance to undergo testing may impact the public health response, through under-identification of pediatric cases. The Rhinoswab is a TGA (Therapeutic Goods Administration) approved anterior nasal swab for children and adults. The design of the Rhinoswab allows for standardisation of the site of biological sampling, as compared with CTDN swabs which are operator dependent. It is designed to be more comfortable and to collect nasal secretions for PCR testing. The Rhinoswab Junior is a smaller paediatric version that has novelty features which add interest and distraction. The child can use the swab themselves, allowing autonomy and control. The capture and elution efficiency of the Rhinoswab has been shown to be comparable, if not slightly superior, to the capture and elution efficiency to the commercially available Copan eSwab by VIDRL (Victorian Infectious Diseases Reference Laboratory) and GNOMIX analyses. The RCH has completed over 30,000 tests in children throughout the COVID-19 Pandemic from March 2020 to June 2021 at the Respiratory Infection Clinic and Emergency Department. The RCH nurses and doctors are well placed to trial the Rhinoswab due to extensive experience in testing children, and have developed related clinical practice guidelines. This trial aims to determine the following in children 5-18 years of age: To determine the sensitivity and specificity of the Rhinoswab compared to the standard CTDN swab, in detecting viruses on the respiratory panel To determine whether Rhinoswab is non-inferior to the standard CTDN swab by comparing Ct values To determine the sensitivity and specificity of the throat swab alone and deep nasal swab alone, compared with the CTDN, in detecting respiratory viruses To investigate the comfort and preference of the Rhinoswab compared to the CTDN swab. To investigate the laboratory handling of the Rhinoswab compared to the CTDN swab. To determine the sensitivity and specificity of the Rhinoswab compared to CTDN swab, and saliva, in detecting respiratory viruses including SARS-CoV-2. In children 1 month to 5 years: • To investigate sensitivity and specificity of Rapid Antigen Test (RAT) compared to CTDN swab and saliva test in detected SARS-CoV-2

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
SARS CoV 2 Infection, COVID-19
Keywords
Rhinoswab Junior

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
The study is organised sequentially into three phases due to research capacity Phase 1: The first 250 participants (5-18 years) will be randomly assigned to Arm 1 and Arm 2 for the clinician collected/supervised phase. Phase 2: 50 participants (5-18 years) will be allocated to Arm 3 for the self-collected Rhinoswab/saliva/combined nose+throat swab. Phase 3: 50 subsequent participants (1m - 5 years) will be allocated to Arm 4 for the self-collect throat+nose/saliva/RAT
Masking
None (Open Label)
Allocation
Randomized
Enrollment
339 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Arm 1 - Clinician Collected/supervised Rhinoswab first, then CTDN swab
Arm Type
Experimental
Arm Description
Rhinoswab test administered and immediately followed by CTDN. Rhinoswab swab tested on respiratory panel vs CTDN swab tested on respiratory panel (standard of care).
Arm Title
Arm 2 - Clinician Collected/supervised CTDN swab first, then Rhinoswab
Arm Type
Experimental
Arm Description
CTDN test administered and immediately followed by Rhinoswab. CTDN swab tested on respiratory panel (standard of care) vs Rhinoswab swab tested on respiratory panel.
Arm Title
Arm 3 - Self-collected Rhinoswab, saliva swab, CTDN
Arm Type
Experimental
Arm Description
In children 5-18 years, the child/parent/guardian collects the three samples, in order of patient/parent preference. All samples will be tested on the SARS-CoV-2 laboratory panel (Allplex™ SARS-CoV-2 Assay - Seegene Inc)
Arm Title
Arm 4 - Self-collected RAT, saliva, CTDN
Arm Type
Experimental
Arm Description
In children 1 month -5 years, the child/parent/guardian collects the three samples, in order of patient/parent preference. Saliva and CTDN samples will be tested on the SARS-CoV-2 laboratory panel (Allplex™ SARS-CoV-2 Assay - Seegene Inc), RAT test kit will be Abbott PanBio
Intervention Type
Device
Intervention Name(s)
Rhinoswab Junior
Intervention Description
Rhinoswab Junior is a single use self-administered nasal swab intended to collect clinical specimens from the patient's nasal passages
Intervention Type
Device
Intervention Name(s)
Combined nose and throat swab
Intervention Description
Combined nose and throat swab (standard of care)
Intervention Type
Device
Intervention Name(s)
Saliva swab
Intervention Description
Saliva swab
Intervention Type
Diagnostic Test
Intervention Name(s)
Abbott Panbio™ COVID-19 antigen self-test kit
Intervention Description
COVID-19 antigen self-test kit for the screening of active COVID-19 infection. It is a single-use, in vitro, visually read rapid immunoassay that uses a human nasal swab specimen for the qualitative detection of nucleocapsid protein SARS-CoV-2 antigen. It is intended to be used manually by untrained lay users (self testing) in a private setting.
Primary Outcome Measure Information:
Title
Sensitivity of Rhinoswab compared with CTDN for 13 viruses on standard respiratory panel (Clinician collected/supervised)
Description
The results (detected/not detected) on all 13 viruses on the standard respiratory panel from both the Rhinoswab and the standard swabs will be obtained, and the sensitivity of the Rhinoswab compared to the CTDN determined. Sensitivity is calculated only in the participants who tested positive for the respective virus using the CTDN swab and is calculated as the proportion patients who tested positive on the Rhinoswab among those who tested positive on the CTDN swab. 95% confidence intervals will be calculated.
Time Frame
5 minutes from administering test
Title
Specificity of Rhinoswab compared with CTDN for 13 viruses on standard respiratory panel (Clinician collected/supervised)
Description
The results (detected/not detected) on all 13 viruses on the standard respiratory panel from both the Rhinoswab and the standard swabs will be obtained, and the specificity of the Rhinoswab compared to the CTDN determined. Specificity is calculated only in participants who tested negative for respiratory viruses and is calculated as the proportion patients who tested negative on Rhinoswab among those who tested negative on CTDN swab. 95% confidence intervals will be calculated.
Time Frame
5 minutes from administering test
Secondary Outcome Measure Information:
Title
Ct-Value of respiratory viruses on Rhinoswab compared with Ct-value of respiratory viruses on CTDN (Clinician-Collected/Supervised)
Description
Median Ct-Value of respiratory viruses on Rhinoswab compared with Ct-value of respiratory viruses on CTDN for each detection will be compared. The CT value for the undetected sample will be set at the maximum number of cycles performed in the laboratory (CT value maximum of 38.73). If the upper limit of the confidence interval is more than 3 Ct-value, the two swabs will be regarded as non-inferior.
Time Frame
5 minutes from administering test
Title
Swab Preference Assessment (Clinician-Collected/Supervised )
Description
The preferability for the Rhinoswab, compared to the standard sample for respiratory virus testing is determined, using the Likert scale or picture-based chart for standardised responses. Descriptive analyses will be used to describe child/parent/research preferences. A) Child/parent/research nurse will be asked to rate comfort for each swab: Extremely Comfortable 1 to Extremely Uncomfortable 5 B) What is your preference for future testing between CTDN and Rhinoswab? C) Which swab was better CTDN vs Rhinoswab?
Time Frame
5 minutes from administering test
Title
Median Ct-value of SARS-CoV-2 on Rhinoswab vs saliva vs CTDN (Self-collected)
Description
Median Ct-Value of SARS-CoV-2 on Rhinoswab, saliva and CTDN will be compared. The CT value for the undetected sample will be set at the maximum number of cycles performed in the laboratory (CT value maximum of 38.73). If the upper limit of the 95% confidence interval for the median difference is less than 3 CT, the Rhinoswab will be regarded as non-inferior.
Time Frame
5 minutes from administering test
Title
Sensitivity of Rhinoswab compared with CTDN for SARS-CoV-2 (Self-collected)
Description
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using the CTDN swab and is calculated as the proportion patients who tested positive on the Rhinoswab among those who tested positive on the CTDN swab.
Time Frame
5 minutes from administering test
Title
Specificity of Rhinoswab compared with CTDN for SARS-CoV-2 (Self-collected)
Description
Specificity is calculated only in participants who tested negative for SARS-CoV-2and is calculated as the proportion patients who tested negative on Rhinoswab among those who tested negative on CTDN swab.
Time Frame
5 minutes from administering test
Title
Comparison of RAT test (detected/not detected) to Ct-values for saliva and standard CTDN for SARS-CoV-2 only (Self-collected)
Description
The SARS-CoV-2 results (detected/not detected) from the RAT test will be compared with Ct-values from saliva and standard CTDN swabs.
Time Frame
15 minutes from administering test
Title
Sensitivity of RAT compared with saliva for SARS-CoV-2 only (Self-collected)
Description
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using saliva and is calculated as the proportion patients who tested positive on RAT among those who tested positive on saliva.
Time Frame
15 minutes from administering test
Title
Sensitivity of RAT compared to standard CTDN for SARS-CoV-2 only (Self-collected)
Description
Sensitivity is calculated only in the participants who tested positive for SARS-CoV-2 using the CTDN swab and is calculated as the proportion patients who tested positive on RAT among those who tested positive on CTDN swab.
Time Frame
15 minutes from administering test
Title
Laboratory handling assessment
Description
At the end of the study, the laboratory staff will be asked: A) Rate the handling experience of Rhinoswab vs CTDN using a Likert scale: Rhinoswab was easier to handle 1 to Rhinoswab was harder to handle 3 B) Was there a difference in processing the Rhinoswab versus the combined throat and deep nasal swab?: Rhinoswab was easier to process/There was no difference in processing/Rhinoswab was harder to process C) How did the Rhinoswab impact the workflow or lab efficiency compared to the standard combined throat and deep nasal swab? 1 Very easy and no impact on workflow or lab efficiency to 5 Very difficult and many complications on workflow or lab efficiency D) What benefits or challenges, did you observe when working with Rhinoswab in the lab? (Freetext)
Time Frame
5 minutes for survey, to be completed up to 14 days post the last participant enrolled

10. Eligibility

Sex
All
Minimum Age & Unit of Time
1 Month
Maximum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Symptomatic and requiring a COVID-19 test at RCH or confirmed/suspected COVID-19 at home. Aged between 1 month -18 years old. Parent/guardian present. Parents/self are able to provide consent. Exclusion Criteria: < 1 month or >18 years old. Recent head or neck surgery Inability (e.g. non-English speaking and if no interpreter is available) or unwillingness to consent
Facility Information:
Facility Name
Shidan Tosif
City
Parkville
State/Province
Victoria
ZIP/Postal Code
3052
Country
Australia

12. IPD Sharing Statement

Plan to Share IPD
Yes
IPD Sharing Plan Description
Beginning 12 months following analysis and article publication, the following will be made available long-term for use by future researchers from a recognised research institution whose proposed use of the data has been ethically reviewed and approved by an independent committee and who accept MCRI's conditions for access: • Individual participant data that underlie the results reported in this article after de-identification (text, tables, figures and appendices).
IPD Sharing Time Frame
Beginning 12 months following analysis and article publication

Learn more about this trial

Diagnosis of Respiratory Viruses in Children With Rhinoswab Junior

We'll reach out to this number within 24 hrs