search
Back to results

Feasibility of Nurse-led Retinal Imaging for Retinopathy of Prematurity Screening Employing the Optos California (N_ORS)

Primary Purpose

Retinopathy of Prematurity

Status
Completed
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
Nurse led screening with Optos ultra-widefield retinal-imaging device
Sponsored by
University of Nottingham
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Retinopathy of Prematurity

Eligibility Criteria

32 Weeks - 1 Year (Child)All SexesDoes not accept healthy volunteers

Inclusion Criteria: Infants (upper age limit 1 years old) eligible for routine ROP screening as part UK ROP screening guidelines (any infant born at or before 32 weeks' gestation and / or weigh 1500 grams or less). Infants with parents/legal guardians who can give written informed consent. Exclusion Criteria: Infants not eligible for routine ROP screening under UK ROP screening guidelines. Infants who are deemed not well enough by the attending consultant neonatologist for retinal examination or retinal imaging. Any premature infant with media opacities that prevents adequate visualisation of the retina. Inability of the parents to give written, informed consent.

Sites / Locations

  • University Hospitals of Derby and Burton

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Nurse led screening for ROP with OPTOS camera

Arm Description

Screening completed by nurse trained in the use of an OPTOS camera to obtain images, at the same time as screening via standard procedure by a trained ophthalmologist using binocular indirect ophthalmoscopy (BIO).

Outcomes

Primary Outcome Measures

Retinopathy of prematurity diagnosis
To evaluate the agreement by measuring the Kappa Co-efficient for agreement, for diagnosis and grading of ROP and posterior pole (pre-plus or plus disease) and peripheral retinal vascular changes, between nurse-led OPTOS imaging and indirect Ophthalmoscopy performed by an ophthalmologist.
Retinopathy of prematurity grading
To evaluate the agreement by measuring the Kappa Co-efficient for agreement, for diagnosis and grading of ROP and posterior pole (pre-plus or plus disease) and peripheral retinal vascular changes, between nurse-led OPTOS imaging and indirect Ophthalmoscopy performed

Secondary Outcome Measures

Full Information

First Posted
July 20, 2023
Last Updated
September 25, 2023
Sponsor
University of Nottingham
Collaborators
University Hospitals of Derby and Burton NHS Foundation Trust
search

1. Study Identification

Unique Protocol Identification Number
NCT06063863
Brief Title
Feasibility of Nurse-led Retinal Imaging for Retinopathy of Prematurity Screening Employing the Optos California
Acronym
N_ORS
Official Title
Feasibility of Nurse-led Retinal Imaging for Retinopathy of Prematurity Screening Employing the Optos California
Study Type
Interventional

2. Study Status

Record Verification Date
September 2023
Overall Recruitment Status
Completed
Study Start Date
May 10, 2021 (Actual)
Primary Completion Date
August 1, 2023 (Actual)
Study Completion Date
August 1, 2023 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Nottingham
Collaborators
University Hospitals of Derby and Burton NHS Foundation Trust

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Retinopathy of prematurity (ROP) is a preventable cause of blindness in babies who are born early i.e. premature. Internationally, there is a shortage of skilled ophthalmologists willing and able to screen for ROP. Even in the UK, not all hospitals have skilled ophthalmologists and premature babies have to travel to other hospitals, often long distances, to have their eyes examined. As a missed examination can lead to sight loss, this is a burden for families and carers of premature babies. To fill this gap, previous studies have explored the use of non-ophthalmologists healthcare workers to increase the workforce screening for ROP. Recently, the Optos ultra-widefield retinal-imaging device (Optos PLC, Dunfermline, Scotland, UK) has been used to help document different stages of ROP in infants. This specialised retinal imaging system uses an internal ellipsoid mirror to capture fundal imaging angles of up to 200 degrees, or more than 80% of the entire retina, in a single image. A single retinal image can be acquired in a quarter of a second and is automatically captured when the infant's pupils are aligned with the Optos imaging device. No contact with the eye is necessary to capture an image of the retina. To date, there are no studies that have validated the Optos as a nurse-led screening tool for ROP. This is a prospective study to determine and validate the feasibility of neonatal nurse-led retinal imagers for ROP screening employing the Optos imaging device. The main purpose of this study will be to test if it is possible for trained nurses to take good images of the back of babies eyes (retina) and if these images can be used by remotely placed ophthalmologists to diagnose and grade ROP. The investigators will compare how good the diagnosis and grading done using Optos images are compared to the current gold standard method (BIO). The investigators will also test how much agreement there is between ophthalmologists in interpreting Optos images by asking two ophthalmologists to grade the images.
Detailed Description
Retinopathy of Prematurity (ROP) is the major cause of blindness in babies who are born early i.e. premature (defined as those born at less than 37 weeks' gestation). All premature infants are at risk of developing ROP and are therefore routinely screened for the condition. With improvements, it has become one of the few preventable causes of childhood blindness, and recent reports suggest that most babies are saved from sight loss with proper screening and treatment. As neonatal care gets better, more premature babies are surviving and the need for ROP screening is increasing all over the world: about 8200 babies need screening in the UK each year. Very few babies need treatment - less than 2% in the UK. At the Royal Derby Hospital (RDH), about 4 to 5 infants are screened each week, with only 1 to 2 needing treatment per year. The international classification of ROP describes ROP by its severity or stage (Stages 1-5), location by zone (I-III), extent by clock hours, and by the presence of pre-plus and plus disease. The aim of screening is to find out if the baby has any of these so that treatment can be done if needed. All babies born before 32 weeks or at less than 1500 g birth weight must have regular screening. For those born at <27 weeks gestation, the first ROP screening examination should be undertaken when at 30 to 31 weeks corrected gestational age while for babies who are more mature at birth, it is done between 4 to 5 weeks of actual age. Follow-up examinations should be performed every 1 to 2 weeks thereafter until the ophthalmologists (eye doctors) can see that the retina is fully matured. If there are signs of ROP, examinations should be performed more frequently, either weekly or twice a week. All ROP screening examinations are currently done by a highly trained ophthalmologist using binocular indirect ophthalmoscopy (BIO), which is considered the gold standard method. The retinal findings are seen and drawn by hand in the patient's notes. These screening examinations are time-consuming for the ophthalmologist, and costly for the medical system as they need the ophthalmologist to be physically present and to do the screening. This makes it difficult for babies in remote hospitals or settings without trained ophthalmologists to have ROP screening. To reduce this difficulty several groups have developed cameras that can take pictures of the retina. The pictures can then be transferred to ophthalmologists who can diagnose and grade the ROP remotely. The most common imaging system used for ROP screening is the RetCam (Clarity Medical Systems, Pleasanton, California, USA). The RetCam imaging system, a hand-held camera, is connected by a fiber optic cable to an electro-optical box housed in a movable cart. To take images with RetCam, the babies pupils have to be dilated (opened up) by using medicines and local painkillers. The eyelids are held open with a lid speculum and the camera probe is applied with a contact lens gel such that it is touching the front of the eye, over the open pupil. RetCam images are not able to include the whole of the back of the eye in one picture and therefore multiple images have to be taken. This takes time and effort from highly-skilled imagers. Also, the picture quality is not good if the pupil is not opened properly or if there is some obstruction in the way such as blood in the eye. As the camera has to touch the eye, it can hurt the eye and make the baby uncomfortable such as by stimulating eye nerves that cause the heart to slow down and lower the baby's blood oxygen levels. Too much pressure on the eye can also change the picture and make the diagnosis difficult. More recently, a new camera, the Optos ultra-widefield retinal-imaging device (Optos PLC, Dunfermline, Scotland, UK) has been used to take and store pictures of different stages of ROP in babies. This camera has a specialised mirror to capture pictures that contain details of nearly all of the retina in a single photo. It is quick, the complete single photo can the taken in a quarter of a second. In addition, it can take pictures without touching the baby's eyes so there is no risk of damage to the eye. Thus, the Optos camera has many advantages over the RetCam. If this camera could be used by nurses trained to take pictures and ophthalmologists could diagnose and grade ROP from these pictures, babies could be screened without every hospital needing to have a specially trained ophthalmologist or the baby travelling distances to go to a centre that had such a doctor. As most babies only need screening, ophthalmologists could ask for only those who need treatment (about 2 in 100 babies) to be transferred to specialist centres. This could reduce the cost of care to the NHS and problems for families of premature babies. In the Derby neonatal unit, the study team have already tested the Optos camera and found that it is safe to use in babies and did not cause them any undue discomfort. In this study, the study team want to see if it is possible to train a nurse to take pictures of the retina using the Optos camera and if ophthalmologists can diagnose and grade ROP accurately using these images. No studies have been done to test this.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Retinopathy of Prematurity

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
52 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Nurse led screening for ROP with OPTOS camera
Arm Type
Experimental
Arm Description
Screening completed by nurse trained in the use of an OPTOS camera to obtain images, at the same time as screening via standard procedure by a trained ophthalmologist using binocular indirect ophthalmoscopy (BIO).
Intervention Type
Diagnostic Test
Intervention Name(s)
Nurse led screening with Optos ultra-widefield retinal-imaging device
Intervention Description
The screening will be completed by nurse trained in using an OPTOS camera, at the same time as screening for ROP by a trained ophthalmologist using standard procedure for screening for ROP using binocular indirect ophthalmoscopy (BIO). Images taken with OPTOS will then be remotely assessed by a qualified independent opthalmologist, to see if they can diagnose and grade ROP accurately using these images
Primary Outcome Measure Information:
Title
Retinopathy of prematurity diagnosis
Description
To evaluate the agreement by measuring the Kappa Co-efficient for agreement, for diagnosis and grading of ROP and posterior pole (pre-plus or plus disease) and peripheral retinal vascular changes, between nurse-led OPTOS imaging and indirect Ophthalmoscopy performed by an ophthalmologist.
Time Frame
18 months
Title
Retinopathy of prematurity grading
Description
To evaluate the agreement by measuring the Kappa Co-efficient for agreement, for diagnosis and grading of ROP and posterior pole (pre-plus or plus disease) and peripheral retinal vascular changes, between nurse-led OPTOS imaging and indirect Ophthalmoscopy performed
Time Frame
18 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
32 Weeks
Maximum Age & Unit of Time
1 Year
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Infants (upper age limit 1 years old) eligible for routine ROP screening as part UK ROP screening guidelines (any infant born at or before 32 weeks' gestation and / or weigh 1500 grams or less). Infants with parents/legal guardians who can give written informed consent. Exclusion Criteria: Infants not eligible for routine ROP screening under UK ROP screening guidelines. Infants who are deemed not well enough by the attending consultant neonatologist for retinal examination or retinal imaging. Any premature infant with media opacities that prevents adequate visualisation of the retina. Inability of the parents to give written, informed consent.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Shalini Ojha, Professor
Organizational Affiliation
University of Nottingham
Official's Role
Principal Investigator
Facility Information:
Facility Name
University Hospitals of Derby and Burton
City
Derby
State/Province
Derbyshire
ZIP/Postal Code
DE22 3DT
Country
United Kingdom

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
30322451
Citation
Fung THM, Abramson J, Ojha S, Holden R. Systemic Effects of Optos versus Indirect Ophthalmoscopy for Retinopathy of Prematurity Screening. Ophthalmology. 2018 Nov;125(11):1829-1832. doi: 10.1016/j.ophtha.2018.06.001. Epub 2018 Jul 6. No abstract available.
Results Reference
background

Learn more about this trial

Feasibility of Nurse-led Retinal Imaging for Retinopathy of Prematurity Screening Employing the Optos California

We'll reach out to this number within 24 hrs