180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
Primary Purpose
Open Angle Glaucoma, Ocular Hypertension, Glaucoma, Open Angle, Pseudo-exfoliative
Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Selective Laser Trabeculoplasty
Neodymium:Yttrium Aluminum Garnet (YAG) laser
Sponsored by
About this trial
This is an interventional treatment trial for Open Angle Glaucoma focused on measuring glaucoma, Elevated IOP, Selective Laser Trabeculoplasty, SLT, open angle glaucoma, ocular hypertension, Glaucoma, Open Angle, Pseudo-exfoliative, pigment dispersion syndrome, Pseudoexfoliation, IOP ≥ 21 mmHg
Eligibility Criteria
Inclusion Criteria:
- patients who have been diagnosed with open-angle glaucoma including ocular hypertension, pseudoexfoliation and pigment dispersion syndrome
- greater than 18 years of age
- initial intraocular pressure (IOP) of ≥ 21 mmHg
Exclusion Criteria:
- prior medical or laser therapy to lower IOP
- previous incisional glaucoma surgery before the study period
Sites / Locations
- Brandywine Eye Center
- Levin Luminais Chronister Eye Associates
Arms of the Study
Arm 1
Arm 2
Arm Type
Active Comparator
Active Comparator
Arm Label
180 degrees
360 degrees
Arm Description
180 degrees of Selective Laser Trabeculoplasty using Neodymium:Yttrium Aluminum Garnet (YAG) laser
360 degrees of Selective Laser Trabeculoplasty using Neodymium:Yttrium Aluminum Garnet (YAG) laser
Outcomes
Primary Outcome Measures
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Three Months of Follow-up
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at three months of follow-up
Secondary Outcome Measures
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at 1 Year of Follow-up
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at 1 year of follow-up
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Time at Which Additional Glaucoma Therapy is Required
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at time at which additional glaucoma therapy is required
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Last Follow-up
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at last follow-up
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT02628223
Brief Title
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
Official Title
A Randomized Trial of 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
Study Type
Interventional
2. Study Status
Record Verification Date
November 2020
Overall Recruitment Status
Completed
Study Start Date
September 2014 (undefined)
Primary Completion Date
December 2017 (Actual)
Study Completion Date
December 2017 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Temple University
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
Selective laser trabeculoplasty (SLT) is a well-recognized way to lower eye pressure in treatment of glaucoma. This treatment is performed for 180 degrees or 360 degrees, and studies at academic centers have shown mixed results when comparing the success rates of 180 degrees or 360 degrees. Both protocols are now typically done by comprehensive ophthalmologists. However, there is no data that compares success rates of 180 degrees and 360 degrees in the community setting.
Detailed Description
This study is designed as a prospective evaluation of the two treatment algorithms for SLT by measuring intraocular pressure (IOP) after treatment. The hypothesis is that 360 degrees of SLT will produce a greater reduction in IOP than 180 degrees of SLT at 3 months follow up.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Open Angle Glaucoma, Ocular Hypertension, Glaucoma, Open Angle, Pseudo-exfoliative, Pigment Dispersion Syndrome, Glaucoma
Keywords
glaucoma, Elevated IOP, Selective Laser Trabeculoplasty, SLT, open angle glaucoma, ocular hypertension, Glaucoma, Open Angle, Pseudo-exfoliative, pigment dispersion syndrome, Pseudoexfoliation, IOP ≥ 21 mmHg
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Investigator
Allocation
Randomized
Enrollment
76 (Actual)
8. Arms, Groups, and Interventions
Arm Title
180 degrees
Arm Type
Active Comparator
Arm Description
180 degrees of Selective Laser Trabeculoplasty using Neodymium:Yttrium Aluminum Garnet (YAG) laser
Arm Title
360 degrees
Arm Type
Active Comparator
Arm Description
360 degrees of Selective Laser Trabeculoplasty using Neodymium:Yttrium Aluminum Garnet (YAG) laser
Intervention Type
Procedure
Intervention Name(s)
Selective Laser Trabeculoplasty
Other Intervention Name(s)
SLT
Intervention Description
The procedure uses light energy provided by a neodymium (Nd):Yttrium Aluminum Garnet (YAG) laser that is directed into the iridocorneal angle via a goniolens viewed through a standard slit lamp.
Intervention Type
Device
Intervention Name(s)
Neodymium:Yttrium Aluminum Garnet (YAG) laser
Other Intervention Name(s)
Nd:YAG laser
Intervention Description
The procedure uses a 400 μm spot size of light energy provided by a low-energy, Q-switched, frequency-doubled (532 nm) neodymium (Nd):Yttrium Aluminum Garnet (YAG) laser with a short pulse duration of 3 nanoseconds that is directed into the iridocorneal angle via a goniolens viewed through a standard slit lamp.
Primary Outcome Measure Information:
Title
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Three Months of Follow-up
Description
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at three months of follow-up
Time Frame
3 months
Secondary Outcome Measure Information:
Title
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at 1 Year of Follow-up
Description
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at 1 year of follow-up
Time Frame
1 year
Title
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Time at Which Additional Glaucoma Therapy is Required
Description
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at time at which additional glaucoma therapy is required
Time Frame
within 1 year of study intervention
Title
Intraocular Pressure (IOP) Measured by Tonometry in Millimeters of Mercury at Last Follow-up
Description
Intraocular pressure (IOP) measured by tonometry in millimeters of mercury at last follow-up
Time Frame
within 1 year of study intervention
Other Pre-specified Outcome Measures:
Title
Number of Participants With Intraocular Pressure (IOP) Spike Assessed by Tonometry
Description
If IOP spike occurs, it will be treated accordingly.
Time Frame
within 1 year of study intervention
Title
Number of Participants With Trabeculitis Assessed by Ophthalmic Exam and Gonioscopy
Description
If trabeculitis occurs, it will be treated accordingly.
Time Frame
within 1 year of study intervention
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
patients who have been diagnosed with open-angle glaucoma including ocular hypertension, pseudoexfoliation and pigment dispersion syndrome
greater than 18 years of age
initial intraocular pressure (IOP) of ≥ 21 mmHg
Exclusion Criteria:
prior medical or laser therapy to lower IOP
previous incisional glaucoma surgery before the study period
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Jeffrey D. Henderer, MD
Organizational Affiliation
Temple University
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Sophia Siu, MD
Organizational Affiliation
Temple University
Official's Role
Study Director
Facility Information:
Facility Name
Brandywine Eye Center
City
Wilmington
State/Province
Delaware
ZIP/Postal Code
19810
Country
United States
Facility Name
Levin Luminais Chronister Eye Associates
City
Thorndale
State/Province
Pennsylvania
ZIP/Postal Code
19372
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
We'll reach out to this number within 24 hrs