AgION Catheter for Preventing Catheter-Related Bloodstream Infections
Primary Purpose
Catheter-Related Infections
Status
Completed
Phase
Not Applicable
Locations
Italy
Study Type
Interventional
Intervention
Umbilical catheterization (AgION )
Umbilical catheterization (ArgyleTM)
Sponsored by
About this trial
This is an interventional prevention trial for Catheter-Related Infections focused on measuring Catheter related bloodstream infection, Umbilical venous catheter, Silver, Preterm infants
Eligibility Criteria
Inclusion Criteria:
- Gestational age < 30 weeks
- Need of an umbilical venous catheter in the first week of life
- Parental informed consent.
Exclusion Criteria:
- Major congenital malformations
- Hydrops fetalis
- Inherited congenital metabolic diseases
- Death during the first week of life
Sites / Locations
- Careggi Univesity Hospital
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
AgION catheter
Non-impregnated polyurethane catheter
Arm Description
Patients in this arm received an AgION impregnated catheter (4.0-5.0 F Lifecath PICC ExpertTM, Vygon, Ecouen, France).
Patients in this arm received a non-impregnated polyurethane umbilical catheter (3.5-5.0 F ArgyleTM, Kendall, Tullamore, Iceland)
Outcomes
Primary Outcome Measures
Incidence of CRBSIs
We evaluated the incidence of CRBSIs (definite plus probable) during the time the UVC was in place.
Secondary Outcome Measures
Infection density
Number of infections/1000 catheter days, likelihood of freedom from CRIBSIS, and signs of catheter intolerance and possible adverse effects from silver ion toxicity were evaluated for the duration of umbilical venous catheterization; occurrence of BPD, IVH, PVL, ROP, and NEC, length of stay in hospital, case fatality rate for infants with CRBSI, and death were evaluated at discharge.
Likelihood of freedom from CRIBSIs
Likelihood of freedom from CRIBSIS for the duration of umbilical venous catheterization
AgION catheters tolerability
Signs of local intolerance, such as skin infection, were recorded. We also evaluated possible adverse effects from silver ion toxicity, such as the occurrence of argyria (blue-grey discoloration of the skin) or hepatic damage (i.e.: increase in AST/ALT enzymes).
Case fatality rate for infants with CRBSI
We evaluated the mortality caused by CRBSI in infants who received AgION-impregnated and non-impregnated groups.
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT01564615
Brief Title
AgION Catheter for Preventing Catheter-Related Bloodstream Infections
Official Title
Reduction of Catheter-Related Bloodstream Infections in Preterm Infants by the Use of Catheters With the AgION Antimicrobial System
Study Type
Interventional
2. Study Status
Record Verification Date
March 2012
Overall Recruitment Status
Completed
Study Start Date
July 2007 (undefined)
Primary Completion Date
June 2009 (Actual)
Study Completion Date
June 2009 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
University of Florence
4. Oversight
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
The investigators assessed if use of AgION-impregnated umbilical catheters can decrease the occurrence of catheter-related bloodstream infections (CRBSI) in preterm infants.
Detailed Description
Recently, a silver zeolite-impregnated catheter has been commercialized. This material, namely the patented silver compound AgION™, releases antimicrobially active silver ions which may help prevent catheter-related bloodstream infections CRBSIs which are frequent in preterm infant.
The investigators hypothesized that the use of AgION-impregnated umbilical catheters could decrease the occurrence of CRBSIs in preterm infants. To assess this hypothesis the investigators carried out a randomized controlled study in which preterm infants needing an umbilical vein catheter would received either an AgION catheter or a traditional non-impregnated polyurethane catheter.
Infants with gestational age < 30 weeks were randomized to receive an AgION- impregnated or non-impregnated polyurethane umbilical venous catheter (UVC) by opening sealed opaque envelopes. The primary end point was the incidence of CRBSIs during the time the UVC was in place.
The investigators studied 86 infants, 41 of whom received the AgION catheter and 45 the non-impregnated catheter. During umbilical venous catheterization 2% of infants in the AgION group developed CRBSI in comparison with 22% of infants in the control group (p=0.005). The incidence density of CRBSIs during the study period was lower in infants who received AgION catheters compared to the control group (2.1/1000 catheter days versus 25.8/1000 catheter days; p<0.001). The occurrence of UVC colonization was similar in both groups. The Kaplan-Meier estimates of the cumulative likelihood of being free of a CRBSI at each day of UVC placement demonstrate the statistically significant (p=0.004) protective effect of AgION impregnated catheters. Moreover, infants in the AgION group had shorter hospital stay (p=0.04), and a lower case fatality rate due to BSI (p=0.01) than infants in the control group.
AgION catheters were well tolerated and none of patients showed signs attributable to silver toxicity.
Multivariate analysis demonstrated that non-impregnated catheter use (OR 12.5, 95% C.l. 2.06-75.9) and catheter placement for more than 7 days (OR 5.1, 95% C.l. 1.13-23.6) increased the risk of developing a CRBSI in our population.
Conclusions. The AgION-impregnated UVCs were effective in decreasing the development of CRBSIs in preterm infants compared to non-impregnated polyurethane UVCs.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Catheter-Related Infections
Keywords
Catheter related bloodstream infection, Umbilical venous catheter, Silver, Preterm infants
7. Study Design
Primary Purpose
Prevention
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
86 (Actual)
8. Arms, Groups, and Interventions
Arm Title
AgION catheter
Arm Type
Experimental
Arm Description
Patients in this arm received an AgION impregnated catheter (4.0-5.0 F Lifecath PICC ExpertTM, Vygon, Ecouen, France).
Arm Title
Non-impregnated polyurethane catheter
Arm Type
Active Comparator
Arm Description
Patients in this arm received a non-impregnated polyurethane umbilical catheter (3.5-5.0 F ArgyleTM, Kendall, Tullamore, Iceland)
Intervention Type
Device
Intervention Name(s)
Umbilical catheterization (AgION )
Intervention Description
Infants received a AgION impregnated catheter (4.0-5.0 F Lifecath PICC ExpertTM, Vygon, Ecouen, France).
Intervention Type
Device
Intervention Name(s)
Umbilical catheterization (ArgyleTM)
Intervention Description
Infants received a polyurethane non-impregnated catheter (3.5-5.0 F ArgyleTM, Kendall, Tullamore, Iceland)
Primary Outcome Measure Information:
Title
Incidence of CRBSIs
Description
We evaluated the incidence of CRBSIs (definite plus probable) during the time the UVC was in place.
Time Frame
Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days
Secondary Outcome Measure Information:
Title
Infection density
Description
Number of infections/1000 catheter days, likelihood of freedom from CRIBSIS, and signs of catheter intolerance and possible adverse effects from silver ion toxicity were evaluated for the duration of umbilical venous catheterization; occurrence of BPD, IVH, PVL, ROP, and NEC, length of stay in hospital, case fatality rate for infants with CRBSI, and death were evaluated at discharge.
Time Frame
Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days
Title
Likelihood of freedom from CRIBSIs
Description
Likelihood of freedom from CRIBSIS for the duration of umbilical venous catheterization
Time Frame
Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days
Title
AgION catheters tolerability
Description
Signs of local intolerance, such as skin infection, were recorded. We also evaluated possible adverse effects from silver ion toxicity, such as the occurrence of argyria (blue-grey discoloration of the skin) or hepatic damage (i.e.: increase in AST/ALT enzymes).
Time Frame
Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days
Title
Case fatality rate for infants with CRBSI
Description
We evaluated the mortality caused by CRBSI in infants who received AgION-impregnated and non-impregnated groups.
Time Frame
Hospital stay duration, an expected average of 80 days
10. Eligibility
Sex
All
Minimum Age & Unit of Time
1 Day
Maximum Age & Unit of Time
7 Days
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Gestational age < 30 weeks
Need of an umbilical venous catheter in the first week of life
Parental informed consent.
Exclusion Criteria:
Major congenital malformations
Hydrops fetalis
Inherited congenital metabolic diseases
Death during the first week of life
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Carlo Dani, MD
Organizational Affiliation
Department of Surgical and Medical Critical Care, Section of Neonatology, University of Florence
Official's Role
Principal Investigator
Facility Information:
Facility Name
Careggi Univesity Hospital
City
Florence
ZIP/Postal Code
50141
Country
Italy
12. IPD Sharing Statement
Learn more about this trial
AgION Catheter for Preventing Catheter-Related Bloodstream Infections
We'll reach out to this number within 24 hrs