search
Back to results

Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements

Primary Purpose

Atrial Fibrillation

Status
Completed
Phase
Not Applicable
Locations
Denmark
Study Type
Interventional
Intervention
Cortrium C3 device
Holter device
Sponsored by
Cortrium
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Atrial Fibrillation

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Clinical diagnosis of atrial fibrillation
  • Investigation of atrial fibrillation

Exclusion Criteria:

  • Language difficulties
  • Impaired cognitive function.

Sites / Locations

  • Department of Cardiology, Bispebjerg-Frederiksberg Hospitals
  • Aleris-Hamlet Private Hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Experimental

Arm Label

AF assessed from Cortrium C3 data

AF assessed from Holter data

Arm Description

Atrial fibrillation assessed from Cortrium C3 device data

Atrial fibrillation assessed from Holter data

Outcomes

Primary Outcome Measures

Atrial fibrillation
Expert readings of long-term ECG reports to assess number of AF paroxysms.
Heart rate (BPM) during atrial fibrillation
Expert readings of long-term ECG reports to assess heart rate in BPM.

Secondary Outcome Measures

Full Information

First Posted
March 11, 2016
Last Updated
January 22, 2020
Sponsor
Cortrium
Collaborators
University Hospital Bispebjerg and Frederiksberg, Aleris-Hamlet Hospitaler København
search

1. Study Identification

Unique Protocol Identification Number
NCT02714907
Brief Title
Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements
Official Title
Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements
Study Type
Interventional

2. Study Status

Record Verification Date
January 2020
Overall Recruitment Status
Completed
Study Start Date
February 2016 (undefined)
Primary Completion Date
July 2017 (Actual)
Study Completion Date
July 2017 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Cortrium
Collaborators
University Hospital Bispebjerg and Frederiksberg, Aleris-Hamlet Hospitaler København

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of this study is to validate the quality of the ECG-signal acquired with the Cortrium C3 monitor. The intention is to evaluate whether the diagnosis of atrial fibrillation based on the ECG signal from the C3 monitor concurs with the current monitoring methods used in clinical practice.
Detailed Description
Development of new cost effective mobile devices and wireless technology has great potential in supervision of critically ill patients in wards as well as ambulant. Through continuous wireless monitoring in both the hospital and the patients home, detection of heart arrhythmias such as atrial fibrillation (AF) will be possible. AF is the cause of a sizeable amount of strokes (15% of all, and more than 35% of the population over 80 years of age), which can be prevented through anticoagulation treatment if provided in time. Thus, many patients are referred to cardiologic ambulatory to be examined for AF, and are subjected to heart monitoring with a so-called Holter or event monitor. This entails the patient be equipped with several electrodes on the chest, to which leads are attached and connected to a sizable and bulky box. The patient carries this box around hanging from the shoulder, belt or something similar for one or several days. It is then required of the patient to come back and deliver the device, after which the data must be read and analysed, in order to work out a further plan for the patient. During admission, a similar system can be attached for continuous heart monitoring. Cortrium (http://cortrium.com) has developed a wireless technology, where a small C3 monitor is attached to the chest with standard electrodes and the leads are built into the actual monitor. The quality of the signal has been tested on healthy adults, but is yet to be tested on patients suffering from arrhythmias The purpose of this study is to validate the quality of the ECG-signal acquired with the Cortrium C3 monitor. The intention is to evaluate whether the diagnosis of atrial fibrillation based on the ECG signal from the C3 monitor concurs with the current monitoring methods used in clinical practice. The measurements are performed on patients under investigation for AF at cardiology ambulatory Y at Frederiksberg-Bispebjerg Hospital and Aleris-Hamlet Hospital, Copenhagen. The patients are outfitted with a C3 monitor simultaneous with the use of the conventional ambulatory apparatus. This is a "Holter monitor" (Rozinn station RZ152+12 and RZ153+ from ScottCare Holter for Windows 2010 (CE0120) and "EventCare SA version" (CE0120), both bought via SEMCA Ap, Skævinge, Denmark. Recordings with the usual apparatus are analysed in the usual fashion in the cardiology ambulatory. A copy of the recordings is registered anonymously and paired with the simultaneous recordings from the C3. The diagnosis is made by two observers, blinded to both patient identity and data source. Thus, data will not be personally identifiable. Validation is performed in collaboration with the department of cardiology. Statistics: With simultaneous supervision of 77 patients with increased incidence of AF it will be possible to determine whether the C3 is capable of detecting AF in at least 95% of the cases which Holter detects. Since the incidence of AF Is lower in the total patient group referred to Holter monitoring, we plan to include 150 patients to acquire the usable number of examinations. Economic Conditions Helen Dominguez is the unfunded, and the responsible consultant of the study. Opeon Aps delivers C3 monitors for this clinical trial as well as brochure guides for patients and health care personnel. There are no economic benefits connected with the present clinical trial. Publication of Results: Opeon ApS (owner of Cortrium) is responsible for processing the material for publication of results in an international peer-reviewed journal as well as in the Danish popular scientific press related to new Medical equipment. Positive, negative and inconclusive results will be published. Recruitment of Participants: Patients who have planned ambulatory arrhythmia recording for diagnosis of intermittent AF will be asked by telephone to consider participating in the study. After reading the participant information flyer, the subjects are invited to in-depth verbal information in the ambulatory. If the subjects accept to participate and provide a signed informed consent, they outfitted with a C3 monitor along with the standard Holter apparatus. The study only includes subjects scheduled for Holter monitoring referred for atrial fibrillation examination, quantification of paroxysms, or heart rate during paroxysms. Ethical Considerations: Ethical Considerations: If the patient agrees to take part in the study, the main disadvantages are that it entails attachment of another three electrodes for the C3 monitor, increasing the risk of skin irritation, and receiving additional instructions for two devices. Since ECG recordings are non-invasive, and the C3 recordings do not result in further ambulatory visits than otherwise planned, we estimated that the strain on the patients is very limited. The use of C3 for estimation of AF in future patients will decrease the trouble of loose leads. For this reason, using the C3 will also simplify the work of the healthcare personnel during the attachment procedure. Overall it may lead to an increase in quality as well as increase the capacity for examining cardiac arrhythmia in the cardiology ambulatory.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Atrial Fibrillation

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
ParticipantOutcomes Assessor
Allocation
Randomized
Enrollment
158 (Actual)

8. Arms, Groups, and Interventions

Arm Title
AF assessed from Cortrium C3 data
Arm Type
Experimental
Arm Description
Atrial fibrillation assessed from Cortrium C3 device data
Arm Title
AF assessed from Holter data
Arm Type
Experimental
Arm Description
Atrial fibrillation assessed from Holter data
Intervention Type
Device
Intervention Name(s)
Cortrium C3 device
Intervention Description
Data is read from Cortrium C3 monitor
Intervention Type
Device
Intervention Name(s)
Holter device
Intervention Description
Date is read from Holter device
Primary Outcome Measure Information:
Title
Atrial fibrillation
Description
Expert readings of long-term ECG reports to assess number of AF paroxysms.
Time Frame
Through study completion, an average of 3 months
Title
Heart rate (BPM) during atrial fibrillation
Description
Expert readings of long-term ECG reports to assess heart rate in BPM.
Time Frame
Through study completion, an average of 3 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Clinical diagnosis of atrial fibrillation Investigation of atrial fibrillation Exclusion Criteria: Language difficulties Impaired cognitive function.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Helena Helena, MD, PhD
Organizational Affiliation
Bispebjerg-Frederiksberg Hospitals
Official's Role
Principal Investigator
Facility Information:
Facility Name
Department of Cardiology, Bispebjerg-Frederiksberg Hospitals
City
Frederiksberg
ZIP/Postal Code
2000
Country
Denmark
Facility Name
Aleris-Hamlet Private Hospital
City
Soborg
ZIP/Postal Code
2860
Country
Denmark

12. IPD Sharing Statement

Plan to Share IPD
Undecided
Citations:
PubMed Identifier
17186981
Citation
Saito T, Tamura K, Uchida D, Saito T, Togashi M, Nitta T, Sugisaki Y. Histopathological features of the resected left atrial appendage as predictors of recurrence after surgery for atrial fibrillation in valvular heart disease. Circ J. 2007 Jan;71(1):70-8. doi: 10.1253/circj.71.70.
Results Reference
background
PubMed Identifier
17653115
Citation
Syed TM, Halperin JL. Left atrial appendage closure for stroke prevention in atrial fibrillation: state of the art and current challenges. Nat Clin Pract Cardiovasc Med. 2007 Aug;4(8):428-35. doi: 10.1038/ncpcardio0933.
Results Reference
background
PubMed Identifier
19111773
Citation
Saltman AE, Gillinov AM. Surgical approaches for atrial fibrillation. Cardiol Clin. 2009 Feb;27(1):179-88, x. doi: 10.1016/j.ccl.2008.09.012.
Results Reference
background
PubMed Identifier
17261702
Citation
Gillinov AM. Advances in surgical treatment of atrial fibrillation. Stroke. 2007 Feb;38(2 Suppl):618-23. doi: 10.1161/01.STR.0000247934.04848.79.
Results Reference
background
PubMed Identifier
10525506
Citation
Al-Saady NM, Obel OA, Camm AJ. Left atrial appendage: structure, function, and role in thromboembolism. Heart. 1999 Nov;82(5):547-54. doi: 10.1136/hrt.82.5.547.
Results Reference
background
PubMed Identifier
19709791
Citation
Fitzmaurice D. Atrial fibrillation and coagulation: who and when? Blood Rev. 2009 Nov;23(6):241-4. doi: 10.1016/j.blre.2009.07.006. Epub 2009 Aug 25.
Results Reference
background
PubMed Identifier
8037127
Citation
Furberg CD, Psaty BM, Manolio TA, Gardin JM, Smith VE, Rautaharju PM. Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study). Am J Cardiol. 1994 Aug 1;74(3):236-41. doi: 10.1016/0002-9149(94)90363-8.
Results Reference
background
PubMed Identifier
8281651
Citation
Page RL, Wilkinson WE, Clair WK, McCarthy EA, Pritchett EL. Asymptomatic arrhythmias in patients with symptomatic paroxysmal atrial fibrillation and paroxysmal supraventricular tachycardia. Circulation. 1994 Jan;89(1):224-7. doi: 10.1161/01.cir.89.1.224.
Results Reference
background
PubMed Identifier
22236222
Citation
Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575. Erratum In: N Engl J Med. 2016 Mar 10;374(10):998.
Results Reference
background
PubMed Identifier
14715182
Citation
Israel CW, Gronefeld G, Ehrlich JR, Li YG, Hohnloser SH. Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: implications for optimal patient care. J Am Coll Cardiol. 2004 Jan 7;43(1):47-52. doi: 10.1016/j.jacc.2003.08.027.
Results Reference
background
PubMed Identifier
24814113
Citation
Thakkar S, Bagarhatta R. Detection of paroxysmal atrial fibrillation or flutter in patients with acute ischemic stroke or transient ischemic attack by Holter monitoring. Indian Heart J. 2014 Mar-Apr;66(2):188-92. doi: 10.1016/j.ihj.2014.02.009. Epub 2014 Mar 4.
Results Reference
background
PubMed Identifier
23535493
Citation
Cotter PE, Martin PJ, Ring L, Warburton EA, Belham M, Pugh PJ. Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke. Neurology. 2013 Apr 23;80(17):1546-50. doi: 10.1212/WNL.0b013e31828f1828. Epub 2013 Mar 27.
Results Reference
background
PubMed Identifier
24963567
Citation
Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, Rymer MM, Thijs V, Rogers T, Beckers F, Lindborg K, Brachmann J; CRYSTAL AF Investigators. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014 Jun 26;370(26):2478-86. doi: 10.1056/NEJMoa1313600.
Results Reference
background
PubMed Identifier
16885201
Citation
Fuster V, Ryden LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Le Heuzey JY, Kay GN, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann S; Task Force on Practice Guidelines, American College of Cardiology/American Heart Association; Committee for Practice Guidelines, European Society of Cardiology; European Heart Rhythm Association; Heart Rhythm Society. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation). Eur Heart J. 2006 Aug;27(16):1979-2030. doi: 10.1093/eurheartj/ehl176. No abstract available. Erratum In: Eur Heart J. 2007 Aug;28(16):2046.
Results Reference
background
PubMed Identifier
20656504
Citation
Lazzaro MA, Krishnan K, Prabhakaran S. Detection of atrial fibrillation with concurrent holter monitoring and continuous cardiac telemetry following ischemic stroke and transient ischemic attack. J Stroke Cerebrovasc Dis. 2012 Feb;21(2):89-93. doi: 10.1016/j.jstrokecerebrovasdis.2010.05.006. Epub 2010 Jul 24.
Results Reference
background
PubMed Identifier
19648586
Citation
Caldwell JC, Contractor H, Petkar S, Ali R, Clarke B, Garratt CJ, Neyses L, Mamas MA. Atrial fibrillation is under-recognized in chronic heart failure: insights from a heart failure cohort treated with cardiac resynchronization therapy. Europace. 2009 Oct;11(10):1295-300. doi: 10.1093/europace/eup201. Epub 2009 Aug 1.
Results Reference
background
PubMed Identifier
22588086
Citation
Nyrnes A, Mathiesen EB, Njolstad I, Wilsgaard T, Lochen ML. Palpitations are predictive of future atrial fibrillation. An 11-year follow-up of 22,815 men and women: the Tromso Study. Eur J Prev Cardiol. 2013 Oct;20(5):729-36. doi: 10.1177/2047487312446562. Epub 2012 May 15.
Results Reference
background
PubMed Identifier
18234005
Citation
Sulfi S, Balami D, Sekhri N, Suliman A, Kapur A, Archbold RA, Ranjadayalan K, Timmis AD. Limited clinical utility of Holter monitoring in patients with palpitations or altered consciousness: analysis of 8973 recordings in 7394 patients. Ann Noninvasive Electrocardiol. 2008 Jan;13(1):39-43. doi: 10.1111/j.1542-474X.2007.00199.x.
Results Reference
background
PubMed Identifier
23634400
Citation
Paudel B, Paudel K. The diagnostic significance of the holter monitoring in the evaluation of palpitation. J Clin Diagn Res. 2013 Mar;7(3):480-3. doi: 10.7860/JCDR/2013/4923.2802. Epub 2013 Mar 1.
Results Reference
background
PubMed Identifier
3875198
Citation
Hertzeanu H, Aron L. Holter monitoring for dizziness and syncope in old age. Acta Cardiol. 1985;40(3):291-9.
Results Reference
background
PubMed Identifier
17664857
Citation
Hennersdorf MG, Schueller PO, Steiner S, Strauer BE. Prevalence of paroxysmal atrial fibrillation depending on the regression of left ventricular hypertrophy in arterial hypertension. Hypertens Res. 2007 Jun;30(6):535-40. doi: 10.1291/hypres.30.535.
Results Reference
background
Available IPD and Supporting Information:
Available IPD/Information Type
Study Protocol
Available IPD/Information URL
http://cortrium.com
Available IPD/Information Comments
In Danish language

Learn more about this trial

Clinical Data Validation of Novel Wireless Cortrium C3 Monitor for Continuous Electrocardiogram Measurements

We'll reach out to this number within 24 hrs