Clinical Performance of Hydrogel vs. Silicone Hydrogel Contact Lenses

Primary Purpose

Myopia

Status
Completed
Phase
Not Applicable
Locations
Spain
Study Type
Interventional
Intervention
ocufilcon D
omafilcon A
methafilcon A
Sponsored by
Coopervision, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for Myopia

Eligibility Criteria

18 Years - 40 Years (Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Is between 18 and 40 years of age (inclusive)
  • Has had a self-reported visual exam in the last two years
  • Is an adapted soft CL (Contact Lens) wearer
  • Has a CL spherical prescription between - 1.00 and - 10.00 (inclusive)
  • Has a spectacle cylinder up to 0.75D (Diopter) in each eye.
  • Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye.
  • Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses.
  • Has clear corneas and no active ocular disease
  • Has read, understood and signed the information consent letter
  • Patient contact lens refraction should fit within the available parameters of the study lenses
  • Is willing to comply with the wear schedule
  • Is willing to comply with the visit schedule

Exclusion Criteria:

  • Has never worn contact lenses before.
  • Currently wears rigid gas permeable contact lenses.
  • Has a history of not achieving comfortable CL wear (5 days per week; > 8 hours/day)
  • Has a CL prescription outside the range of - 1.00 to -10.00D
  • Has a spectacle cylinder ≥1.00D of cylinder in either eye.
  • Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye.
  • Presence of clinically significant (grade 2-4) anterior segment abnormalities.
  • Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear.
  • Slit lamp findings that would contraindicate contact lens wear such as:

    • Pathological dry eye or associated findings
    • Pterygium, pinguecula, or corneal scars within the visual axis
    • Neovascularization > 0.75 mm in from of the limbus
    • Giant papillary conjunctivitis (GCP) worse than grade 1
    • Anterior uveitis or iritis (past or present)
    • Seborrheic eczema, Seborrheic conjunctivitis
    • History of corneal ulcers or fungal infections
    • Poor personal hygiene
  • Has a known history of corneal hypoesthesia (reduced corneal sensitivity)
  • Has aphakia, keratoconus or a highly irregular cornea.
  • Has Presbyopia or has dependence on spectacles for near work over the contact lenses.
  • Has undergone corneal refractive surgery.
  • Is participating in any other type of eye related clinical or research study.

Sites / Locations

  • Optometry Research Group (GIO) Optics Department, University of Valencia

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm Type

Experimental

Active Comparator

Active Comparator

Arm Label

enfilcon A / omafilcon A

enfilcon A / ocufilcon D

enfilcon A / methafilcon A

Arm Description

Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.

Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.

Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.

Outcomes

Primary Outcome Measures

Participant's Subjective Rating for Lens Handling - Enfilcon A / Omafilcon A
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1 (1 hour). Rated by questionnaires (0= Very difficult 0-100, 100= very easy).
Participant's Subjective Rating for Lens Handling - Enfilcon A / Ocufilcon D
Surveyed after 1 hour of lens wear for each lens at lens removal for Pair #2 (1 hour). Rated by questionnaires (0=Very difficult 0-100, 100= very easy).
Participant's Subjective Rating for Lens Handling - Enfilcon A / Methafilcon A
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #3. Rated by questionnaires (0-100 0=Very difficult, 100= very easy).
Participants Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D
Surveyed after insertion of each lens Pair #2 (at insertion). Rated by Questionnaire (0-100,0=Can't be worn and causes pain, 100=can't feel).
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A
Surveyed after insertion of each lens at baseline visit for Pair #1. Rated by questionnaires (0-100, 0-Can't be worn and causes pain,100= can't feel).
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A
Surveyed after insertion Pair #3 (baseline). Rated by questionnaires (0-100, 0-Can't be worn, 100= can't feel).
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A
Surveyed after 1 hour post settling for Pair #1. Rated by questionnaires (0-100, 0= Can't be worn and causes pain, 100= can't feel).
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100 0=Can't be worn and causes pain, 100= can't feel).
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0=Can't be worn and causes pain 100= can't feel).
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A
Surveyed after insertion of each lens Pair #1 at (Baseline visit). Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D
Surveyed at insertion of each lens Pair #2 by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A
Surveyed after insertion of each lens for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A
Surveyed after 1 hour post settling (1 hour) of lens wear for Pair #1. Rated by subjects preference for test lens or control lens (Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Omafilcon A
Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Ocufilcon D
Assessed after 1 hour post settling for Pair #2. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Methafilcon A
Assessed after 1 hour post settling for Pair #3. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Omafilcon A
Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp. (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Ocufilcon D
Assessed after 1 hour post settling for Pair #2, (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Methafilcon A
Assessed after 1 hour post settling for Pair #3. (Scale 0%-100%, 0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support)
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Omafilcon A
Assessed after 1 hour post settling of lens wear for Pair #1. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable).
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Ocufilcon D
Assessed after 1 hour post settling for Pair #2. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Methafilcon A
Assessed after 1 hour post settling for Pair #3, (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A
Surveyed after insertion of each lens for Pair #1 at baseline visit. Rated by questionnaires (0-100, 0=no sensation of stinging/burning, 100= extreme stinging).
Participant Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D
Surveyed after insertion of each lens Pair #2 at baseline. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging)
Participant Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A
Surveyed after insertion of each lens for Pair #3. Rated by questionnaires (0-100,0=no sensation of stinging/burning, 100=extreme stinging).
Participants Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging).
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100,0= no sensation of stinging/burning, 100= extreme stinging).
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0= no sensation of stinging/burning,100= extreme stinging).
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Omafilcon A
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs Pair #1. LogMAR Visual Acuity (VA) to nearest letter)
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Ocufilcon D
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #2. LogMAR Visual Acuity (VA) to nearest letter)
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Methafilcon A
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #3. LogMAR Visual Acuity (VA) to nearest letter)

Secondary Outcome Measures

Full Information

First Posted
April 28, 2014
Last Updated
March 2, 2017
Sponsor
Coopervision, Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT02131402
Brief Title
Clinical Performance of Hydrogel vs. Silicone Hydrogel Contact Lenses
Official Title
Non-Dispensing Fitting Study Comparing the Clinical Performance of Hydrogel vs. Silicone Hydrogel Sphere Design Contact Lenses
Study Type
Interventional

2. Study Status

Record Verification Date
March 2017
Overall Recruitment Status
Completed
Study Start Date
May 2014 (undefined)
Primary Completion Date
May 2014 (Actual)
Study Completion Date
June 2014 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Coopervision, Inc.

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
The aim of this non-dispensing fitting study is to evaluate the subjective comfort, lens handling, lens fitting characteristics and visual acuity of different hydrogel lens designs versus silicone hydrogel lenses
Detailed Description
This is a 60-subject, double masked, randomized, contra lateral, non-dispensing fitting trial comparing different lens materials (hydrogel vs silicone hydrogel). It is anticipated that this study will involve 2 visits, for each lens pair, as follows: Visits: V1 (lens dispensing), V2 (1 hour post lens settling). Each subject will be randomized to wear the test and control lenses in a series of three short fitting comparisons.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Myopia

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
ParticipantInvestigator
Allocation
Randomized
Enrollment
60 (Actual)

8. Arms, Groups, and Interventions

Arm Title
enfilcon A / omafilcon A
Arm Type
Experimental
Arm Description
Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.
Arm Title
enfilcon A / ocufilcon D
Arm Type
Active Comparator
Arm Description
Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.
Arm Title
enfilcon A / methafilcon A
Arm Type
Active Comparator
Arm Description
Participants wear a pair of lenses, with a test lens in one eye and a control lens in the contra lateral eye. After approximately 1 hour of lens wear, the lenses will be removed and the next pair will be inserted. This will be repeated for a total of three pairs of lenses.
Intervention Type
Device
Intervention Name(s)
ocufilcon D
Other Intervention Name(s)
Hydrogel Contact Lens
Intervention Description
Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (ocufilcon D) in the contra lateral eye.
Intervention Type
Device
Intervention Name(s)
omafilcon A
Other Intervention Name(s)
Hydrogel Contact Lens
Intervention Description
Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (omafilcon A) in the contra lateral eye.
Intervention Type
Device
Intervention Name(s)
methafilcon A
Other Intervention Name(s)
Hydrogel Contact Lens
Intervention Description
Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (methafilcon A) in the contra lateral eye.
Primary Outcome Measure Information:
Title
Participant's Subjective Rating for Lens Handling - Enfilcon A / Omafilcon A
Description
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1 (1 hour). Rated by questionnaires (0= Very difficult 0-100, 100= very easy).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Handling - Enfilcon A / Ocufilcon D
Description
Surveyed after 1 hour of lens wear for each lens at lens removal for Pair #2 (1 hour). Rated by questionnaires (0=Very difficult 0-100, 100= very easy).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Handling - Enfilcon A / Methafilcon A
Description
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #3. Rated by questionnaires (0-100 0=Very difficult, 100= very easy).
Time Frame
1 hour post settling
Title
Participants Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D
Description
Surveyed after insertion of each lens Pair #2 (at insertion). Rated by Questionnaire (0-100,0=Can't be worn and causes pain, 100=can't feel).
Time Frame
Baseline
Title
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A
Description
Surveyed after insertion of each lens at baseline visit for Pair #1. Rated by questionnaires (0-100, 0-Can't be worn and causes pain,100= can't feel).
Time Frame
Baseline
Title
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A
Description
Surveyed after insertion Pair #3 (baseline). Rated by questionnaires (0-100, 0-Can't be worn, 100= can't feel).
Time Frame
Baseline
Title
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A
Description
Surveyed after 1 hour post settling for Pair #1. Rated by questionnaires (0-100, 0= Can't be worn and causes pain, 100= can't feel).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D
Description
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100 0=Can't be worn and causes pain, 100= can't feel).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A
Description
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0=Can't be worn and causes pain 100= can't feel).
Time Frame
1 hours post settling
Title
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A
Description
Surveyed after insertion of each lens Pair #1 at (Baseline visit). Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).
Time Frame
Baseline
Title
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D
Description
Surveyed at insertion of each lens Pair #2 by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).
Time Frame
Baseline
Title
Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A
Description
Surveyed after insertion of each lens for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).
Time Frame
Baseline
Title
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A
Description
Surveyed after 1 hour post settling (1 hour) of lens wear for Pair #1. Rated by subjects preference for test lens or control lens (Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D
Description
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A
Description
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Omafilcon A
Description
Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Ocufilcon D
Description
Assessed after 1 hour post settling for Pair #2. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Methafilcon A
Description
Assessed after 1 hour post settling for Pair #3. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Omafilcon A
Description
Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp. (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Ocufilcon D
Description
Assessed after 1 hour post settling for Pair #2, (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Methafilcon A
Description
Assessed after 1 hour post settling for Pair #3. (Scale 0%-100%, 0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Omafilcon A
Description
Assessed after 1 hour post settling of lens wear for Pair #1. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable).
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Ocufilcon D
Description
Assessed after 1 hour post settling for Pair #2. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Methafilcon A
Description
Assessed after 1 hour post settling for Pair #3, (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A
Description
Surveyed after insertion of each lens for Pair #1 at baseline visit. Rated by questionnaires (0-100, 0=no sensation of stinging/burning, 100= extreme stinging).
Time Frame
Baseline
Title
Participant Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D
Description
Surveyed after insertion of each lens Pair #2 at baseline. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging)
Time Frame
Baseline
Title
Participant Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A
Description
Surveyed after insertion of each lens for Pair #3. Rated by questionnaires (0-100,0=no sensation of stinging/burning, 100=extreme stinging).
Time Frame
Baseline
Title
Participants Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A
Description
Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D
Description
Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100,0= no sensation of stinging/burning, 100= extreme stinging).
Time Frame
1 hour post settling
Title
Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A
Description
Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0= no sensation of stinging/burning,100= extreme stinging).
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Omafilcon A
Description
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs Pair #1. LogMAR Visual Acuity (VA) to nearest letter)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Ocufilcon D
Description
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #2. LogMAR Visual Acuity (VA) to nearest letter)
Time Frame
1 hour post settling
Title
Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Methafilcon A
Description
Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #3. LogMAR Visual Acuity (VA) to nearest letter)
Time Frame
1 hour post settling

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
40 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Is between 18 and 40 years of age (inclusive) Has had a self-reported visual exam in the last two years Is an adapted soft CL (Contact Lens) wearer Has a CL spherical prescription between - 1.00 and - 10.00 (inclusive) Has a spectacle cylinder up to 0.75D (Diopter) in each eye. Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye. Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses. Has clear corneas and no active ocular disease Has read, understood and signed the information consent letter Patient contact lens refraction should fit within the available parameters of the study lenses Is willing to comply with the wear schedule Is willing to comply with the visit schedule Exclusion Criteria: Has never worn contact lenses before. Currently wears rigid gas permeable contact lenses. Has a history of not achieving comfortable CL wear (5 days per week; > 8 hours/day) Has a CL prescription outside the range of - 1.00 to -10.00D Has a spectacle cylinder ≥1.00D of cylinder in either eye. Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye. Presence of clinically significant (grade 2-4) anterior segment abnormalities. Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear. Slit lamp findings that would contraindicate contact lens wear such as: Pathological dry eye or associated findings Pterygium, pinguecula, or corneal scars within the visual axis Neovascularization > 0.75 mm in from of the limbus Giant papillary conjunctivitis (GCP) worse than grade 1 Anterior uveitis or iritis (past or present) Seborrheic eczema, Seborrheic conjunctivitis History of corneal ulcers or fungal infections Poor personal hygiene Has a known history of corneal hypoesthesia (reduced corneal sensitivity) Has aphakia, keratoconus or a highly irregular cornea. Has Presbyopia or has dependence on spectacles for near work over the contact lenses. Has undergone corneal refractive surgery. Is participating in any other type of eye related clinical or research study.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Robert Montés-Mico, OD MPhil PhD
Organizational Affiliation
Optics Department, University of Valencia
Official's Role
Principal Investigator
Facility Information:
Facility Name
Optometry Research Group (GIO) Optics Department, University of Valencia
City
Valencia
ZIP/Postal Code
46100
Country
Spain

12. IPD Sharing Statement

Learn more about this trial