search
Back to results

Correlation of Continuous Glucose Monitoring and Glucose Tolerance Testing With Pregnancy Outcomes

Primary Purpose

Diabetes, Gestational

Status
Completed
Phase
Phase 1
Locations
United States
Study Type
Interventional
Intervention
The Seven Continuous Glucose Monitoring System
Sponsored by
Stanford University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Diabetes, Gestational

Eligibility Criteria

18 Years - 50 Years (Adult)FemaleDoes not accept healthy volunteers

Inclusion Criteria:

  • Pregnant patients
  • Age 18-50
  • Gestational age less than 28 weeks

Exclusion Criteria:

  • Minors less than 18 years of age
  • Multiple gestation
  • Known fetal anomalies

Sites / Locations

  • Santa Clara Valley Medical Center
  • Stanford University School of Medicine

Arms of the Study

Arm 1

Arm Type

Other

Arm Label

Continuous Glucose Monitor in pregnancy

Arm Description

The Seven Continuous Glucose Monitoring System: Between 24-28 weeks of gestation, the recommended period of glucola testing, a soft sensor for continuous glucose monitoring system (CGMS) will be inserted superficially under the skin. The patient will be instructed on how to wear and care for the device. She will wear the CGMS for 7 days, then return to the clinic for removal of the device, and downloading of the data. Finger stick blood glucoses will be checked by the patient 2 times daily during the 7 days of wearing the CGMS.

Outcomes

Primary Outcome Measures

Correlation Between Glucose AUC and Birth Weight.
For each patient's CGM data, we calculated the total area under the curve (AUC) for values above the predefined cutoffs of 110, 120, 130, 140, and 180 mg/dL. Patients wore the CGM for different amounts of time; therefore, the total AUC for the entire duration of CGM use was divided by the number of 24-hour periods of data collection. We called these normalized values "AUC-110," "AUC-120," "AUC-130," "AUC-140," and "AUC-180," and they reflect both the magnitude and duration of hyperglycemic excursions above the predetermined thresholds in an average 24-hour period. Birth weight percentile was determined using birth weight data derived from 1999 and 2000 United States Natality datasets. The correlation coefficient (r) was calculated between birth weight percentiles and each of the following: AUC-110, AUC-120, AUC-130, AUC-140, AUC-180, and 1-hour GCT result.

Secondary Outcome Measures

Pregnancy and Delivery Characteristics for Participants With AUC-130 <= 22,000 and AUC-130 > 22,000
For our secondary outcome analyses,we chose to focus on AUC-130 because 130 mg/dL is a common threshold used when treating gestational diabetics. In addition, 130 mg/dL was the threshold used in an earlier pilot study performed at our institution because it had the best correlation with birth weight percentile. Secondary outcomes were compared between these two groups using the chi-square test. Data were analyzed using Stata 11.2. AUC-130 values were divided into "high" and "low" at a cutoff of 22,000, which was the 90th percentile of AUC-130 values.

Full Information

First Posted
February 20, 2009
Last Updated
April 13, 2016
Sponsor
Stanford University
Collaborators
DexCom, Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT00850135
Brief Title
Correlation of Continuous Glucose Monitoring and Glucose Tolerance Testing With Pregnancy Outcomes
Official Title
Correlation of Continuous Glucose Monitoring and Glucose Tolerance Testing With Pregnancy Outcomes
Study Type
Interventional

2. Study Status

Record Verification Date
April 2016
Overall Recruitment Status
Completed
Study Start Date
February 2009 (undefined)
Primary Completion Date
July 2014 (Actual)
Study Completion Date
September 2015 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Stanford University
Collaborators
DexCom, Inc.

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
Diabetic pregnant patients are at risk for adverse pregnancy outcomes, including larger than expected fetuses and unplanned operative deliveries, due to elevated blood glucose levels. the one-hour glucola test is currently used to screen pregnant patients for gestational diabetes. This involves ingesting a 50-gram glucose load, followed by a blood test one hour later. We wish to compare 7-day continuous glucose monitoring to the one-hour glucola test, and determine which one correlates better with adverse pregnancy outcomes as well as which one more accurately identifies patients at risk for adverse pregnancy outcomes.
Detailed Description
All pregnant patients without pre-existing diabetes will be eligible for the study. Interest in participation will be determined at their initial prenatal visit. Those that are interested will be consented. Between 24-28 weeks of gestation, the recommended period of glucola testing, a soft sensor for continuous glucose monitoring system (CGMS) will be inserted superficially under the skin. The patient will be instructed on how to wear and care for the device. She will wear the CGMS for 7 days, then return to the clinic for removal of the device, and downloading of the data. She will perform the routine glucola test sometime between days 2 to 7 . Finger stick blood glucoses will be checked by the patient 2 times daily during the 7 days of wearing the CGMS. Results of CGMS will not be available to the patient or her physician until after completion of the pregnancy. The patient will be treated routinely, based on the results of the routine glucola test.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Diabetes, Gestational

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 1, Phase 2
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
57 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Continuous Glucose Monitor in pregnancy
Arm Type
Other
Arm Description
The Seven Continuous Glucose Monitoring System: Between 24-28 weeks of gestation, the recommended period of glucola testing, a soft sensor for continuous glucose monitoring system (CGMS) will be inserted superficially under the skin. The patient will be instructed on how to wear and care for the device. She will wear the CGMS for 7 days, then return to the clinic for removal of the device, and downloading of the data. Finger stick blood glucoses will be checked by the patient 2 times daily during the 7 days of wearing the CGMS.
Intervention Type
Device
Intervention Name(s)
The Seven Continuous Glucose Monitoring System
Intervention Description
Between 24-28 weeks of gestation, the recommended period of glucola testing, a soft sensor for continuous glucose monitoring system (CGMS) will be inserted superficially under the skin. The patient will be instructed on how to wear and care for the device. She will wear the CGMS for 7 days, then return to the clinic for removal of the device, and downloading of the data. Finger stick blood glucoses will be checked by the patient 2 times daily during the 7 days of wearing the CGMS.
Primary Outcome Measure Information:
Title
Correlation Between Glucose AUC and Birth Weight.
Description
For each patient's CGM data, we calculated the total area under the curve (AUC) for values above the predefined cutoffs of 110, 120, 130, 140, and 180 mg/dL. Patients wore the CGM for different amounts of time; therefore, the total AUC for the entire duration of CGM use was divided by the number of 24-hour periods of data collection. We called these normalized values "AUC-110," "AUC-120," "AUC-130," "AUC-140," and "AUC-180," and they reflect both the magnitude and duration of hyperglycemic excursions above the predetermined thresholds in an average 24-hour period. Birth weight percentile was determined using birth weight data derived from 1999 and 2000 United States Natality datasets. The correlation coefficient (r) was calculated between birth weight percentiles and each of the following: AUC-110, AUC-120, AUC-130, AUC-140, AUC-180, and 1-hour GCT result.
Time Frame
CGM measured 7 days at beginning of pregnancy,birth weight measured a time of delivery
Secondary Outcome Measure Information:
Title
Pregnancy and Delivery Characteristics for Participants With AUC-130 <= 22,000 and AUC-130 > 22,000
Description
For our secondary outcome analyses,we chose to focus on AUC-130 because 130 mg/dL is a common threshold used when treating gestational diabetics. In addition, 130 mg/dL was the threshold used in an earlier pilot study performed at our institution because it had the best correlation with birth weight percentile. Secondary outcomes were compared between these two groups using the chi-square test. Data were analyzed using Stata 11.2. AUC-130 values were divided into "high" and "low" at a cutoff of 22,000, which was the 90th percentile of AUC-130 values.
Time Frame
CGM measured 7 days at beginning of pregnancy,birth weight measured a time of delivery

10. Eligibility

Sex
Female
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
50 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Pregnant patients Age 18-50 Gestational age less than 28 weeks Exclusion Criteria: Minors less than 18 years of age Multiple gestation Known fetal anomalies
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Yasser Yehia El-Sayed
Organizational Affiliation
Stanford University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Santa Clara Valley Medical Center
City
San Jose
State/Province
California
ZIP/Postal Code
95128
Country
United States
Facility Name
Stanford University School of Medicine
City
Stanford
State/Province
California
ZIP/Postal Code
94305
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
25262455
Citation
Sung JF, Kogut EA, Lee HC, Mannan JL, Navabi K, Taslimi MM, El-Sayed YY. Correlation of continuous glucose monitoring profiles with pregnancy outcomes in nondiabetic women. Am J Perinatol. 2015 Apr;32(5):461-8. doi: 10.1055/s-0034-1390344. Epub 2014 Sep 28.
Results Reference
result

Learn more about this trial

Correlation of Continuous Glucose Monitoring and Glucose Tolerance Testing With Pregnancy Outcomes

We'll reach out to this number within 24 hrs