Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (PhA)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Bioelectrical Phase Angle (PhA) - as derived from equations related to the parameters of BIVA - recently surged as a possible biomarker for patients with HF. Studies provided data about the application of PhA in the clinical management and in the overall risk stratification of HF patients.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (R)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Resistance (R, in Ohm)- is related to the amount of body fluids in the sum of intra- (ICW) and extracellular (ECW) water.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (Xc)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Reactance (Xc, in Ohm)-is mainly linked to the inner characteristics of the cell membranes.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (FFM)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Fat-free mass (FFM, kg)- represents the sum of bone mineral content (BMC) and total lean tissue measurements.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (FM)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Fat mass (FM, Kg) - is the total weight of the body minus the weight of any fat measured. This gives an indication of the water, bone, skin, and internal organs as a combined weight.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (BCM)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Body cell mass (BCM,Kg) -is the metabolically active cell mass involved in O2 consumption, CO2 production and energy expenditure. BCM measurement has been suggested as a tool for the evaluation of nutritional status. Since BCM is closely related to energy expenditure, it could also represent a good reference value for the calculation of nutrient needs
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (ECW)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Extracellular water (ECW, L/m) - is the aqueous component that surrounds cells and reflects clinical status in patients with acute or chronic diseases.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (TBW)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Total body water (TBW, L/m)- is integral to clinical care. It has significant implications for patient care that include the dosing of medications, assessment and treatment of dehydration, fluid, and energy requirements for parenteral nutrition, and dialysis prescriptions.
Physiological biomarkers _Bioelectrical Impedance Analysis (BIA)- (ECW/TBW)
Instrument: Nutrilab Bioimpedance device (Akern 2016 with Biatrodes, Akern electrodes) Extracellular Water/Total Body Water Analysis (ECW/TBW)-ratio of Extracellular Water(ECW) to Total Body Water(TBW); an important indicator of body water balance. In a healthy state, ECW/TBW ratio should fall within the range 0.360 to 0.390
Physiological biomarkers _Spirometric assessment-(TV)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Tidall Volume (TV)-the amount of air moved in a normal inspiration or exhalation [TV,(mL/Kg)].
Physiological biomarkers _Spirometric assessment-(VC)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Vital Capacity (VC)-The amount of air that is moved in a maximal unforced inspiration or expiration. [VC,(L)].
Physiological biomarkers _Spirometric assessment-(IRV)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Inspiratory reserve volume(IRV)-Difference between the maximum volume that can be breathed in during a normal breath and in a maximal breath [IRV,(L)].
Physiological biomarkers _Spirometric assessment-(ERV)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Inspiratory reserve volume(IRV)-Difference between the maximum volume that can be exhaled in a normal breath and in a maximal breath [ERV,(L)].
Physiological biomarkers _Spirometric assessment-(IC)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Inspiratory Capacity (IC)-The amount of air that can be breathed in after a normal exhalation [IC,(L)].
Physiological biomarkers _Spirometric assessment-(FVC)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Forced Vital Capacity (FVC)-The amount of air moved in a maximal forced inspiration or expiration [FVC,(%)]; [FVC,(L)].
Physiological biomarkers _Spirometric assessment-(FEV1)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Forced Espiratory Volume1, (FEV1)-The amount of air moved in the first second of a forced exhalation; [FEV1,(mL/seg)].
Physiological biomarkers _Spirometric assessment-(PEF)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Peak Espiratory Flow, (PEF)-The maximum amount of air that can be exhaled per second in a forced exhalation.[PEF,(mL/seg)]; [PEF,(%)]
Physiological biomarkers _Spirometric assessment-(MIP)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Maximal inspiratory pressure(MIP)-the pressure generated during maximal inspiratory effort against a closed system.[MIP,(cm H2O)]
Physiological biomarkers _Spirometric assessment-(MEP)
Instrument: Spirometry device (Spiro USB and MicroRPM, Micro Medical) Maximal Espiratory Pressure (MEP)-the pressure generated during maximal espiratory effort against a closed system.[MEP,(cm H2O)]
Physiological biomarkers _Dynamometric assesment-(MDR-Hd-sEMG)
Instrument: High-Density electromyography device (HDEMG) (64-channel EMG amplifier; OT Bioelettronica+) Mean Discharge Rate of Tibialis Anterior Motor Units [MDR-Hd-sEMG,(Hz)].
Physiological biomarkers _Dynamometric assesment-(VC-Hd-sEMG)
Instrument: High-Density electromyography device (HDEMG) (64-channel EMG amplifier; OT Bioelettronica+) Speed of propagation of Tibialis Anterior Motor Units [VC-Hd-sEMG,(m/s)].
Physiological biomarkers _Dynamometric assesment- (F-Iso-FD-din)
Instrument: Dynamometer (J Tech Medical, Powertrack II Commander) Isometric strength in dorsiflexion of the ankle in both limbs during a 5-second maximal test using a digital hand-held dynamometer [F-Iso.FD-din,(N)].
Physiological biomarkers _Dynamometric assesment- (F-Iso-FD-S)
Instrument: S-Type load cell (Biometrics Ltd) Isometric strength in dorsiflexion of the ankle in both limbs tests using S-Type load cell. The signal shall be analysed and processed using the required software. [F-Iso.FD-S].
Physiological biomarkers _Dynamometric assesment-Timed Up and Go (TUG)
Instruments: a long corridor, a chair, a cone and a chronometer Measure: Time (seg) it takes to get up from a chair, walk 3 meters, turn around, return to the chair and sit down again.
Physiological biomarkers _Dynamometric assesment-Six minute walk test (6-MWT)
Instruments: a long corridor and a chronometer Measure: Evaluate the distance (m) a participant can walk for 6 minutes.
Physiological biomarkers _Dynamometric assesment-Short Physical performance Battery (SPPB)
Instruments: a long corridor, a chair, and a chronometer Measure: A set of short tests that time the time it takes to cover a short distance (4 m), repeat 5 times sit-stand up from the chair, and a set of balance tests (feet together, semi-tandem, and tandem). The end result is a score.
Physiological biomarkers_Metabolic biomarkers_Blood lactate
Instruments: Lactate Pro 2 Blood Lactate Analyzer Measure. Blood lactate (mmol/L)
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(Peak HR)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Peak of Heart Rate [Peak HR,(bpm)].
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(HRR)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Heart Rate Reserve (HRR)- the difference between the predicted maximal heart rate and the heart rate measured in VO2peak. [HRR,(bpm)].
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(VO2-VT1)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Ventilatory threshold oxygen consumption (VO2-VT1)- submaximal parameter of cardiorespiratory fitness [VO2-VT1,(mL/min)]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(VO2/HR,O2 pulse)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Oxygen pulse [O2 pulse] is the ratio between VO2 (mLO2/min) and heart rate (HR - bpm).
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(CRE)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Chronotropic Response to Exercise (CRE)-percentage of the chronotropic index [CRE,(%)]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)- (OUES)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Oxygen uptake efficiency slope (OUES)- the ratio of VO2 to the logarithm in base 10 of VE. OUES can be extracted from submaximal tests. [OUES]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(RER)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: The respiratory exchange ratio [RER] is the ratio of VCO2/VO2
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(PeakW)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Peak W (Peak work rate)- highest work rate achieved during a maximum of 30 seconds during a stress test [PeakW,(W/min)].
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(ΔVO2/ΔWR)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: [ΔVO2/ΔWR] Relationship. It is defined as the relationship between VO2 (Y-axis in mL.min-1) and workload (X-axis in Watts), measured only during exercise on a cycle ergometer with ramp protocol, whose value is progressively and linearly incremented until maximal effort.
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(PeakVE)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Peak Pulmonary Ventilation (PeakVE)- highest volume of air moved in and out of the lung [PeakVE,(L/min)]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(Vd/Vt)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Physiologic dead space over tidal volume (Vd/Vt) - a routine measurement, expressing the ratio of dead-space ventilation (VD) to tidal ventilation (VT)
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(VE/MVV)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Breathing reserve [VE/MVV] represents the ratio between maximal ventilation during exercise (VE) and maximum voluntary ventilation (MVV) at rest, both variables in L/min.
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(PETCO2)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: End-tidal CO2 partial pressure [PETCO2, (mmHg)]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(PETO2)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: End-tidal O2 partial pressure [PETO2, (mmHg)]
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(VE/VCO2)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Ventilatory equivalents for oxygen [VE/VO2], the ratios between pulmonary ventilation and CO2 production(VE/VCO2)
Physiological biomarkers _Cardiopulmonary Exercise Testing (CPET)-(VE/VO2)
Instruments: Cardiopulmonary Exercise Testing at Ciclo-ergometer Measure: Ventilatory equivalents for oxygen [VE/VO2], the ratios between pulmonary ventilation and O2 consumption (VE/VO2)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_hematocrit
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: hematocrit (%)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_hemoglobin
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: hemoglobin 1AC, blood (%)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Mean Corpuscular Volume (MCV)
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: mean corpuscular volume [MCV,(fL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Mean Corpuscular Hemoglobin (MCH)
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: mean corpuscular hemoglobin [MCH,(pg)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Mean Corpuscular Hemoglobin Concentration (MCHC)
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: mean corpuscular hemoglobin [MCHC,(g/dL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Leukocytes
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: leukocytes (mg/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Platelet count
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: platelet count (units/mcL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Glomerular Filtration Rate (GFR)
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: glomerular filtration rate [GFR, (mL/min/1.73m²)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Creatinine
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: creatinine (mg/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Glucose
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: glucose (mmol/L)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Uric Acid
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: uric acid (mg/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_sodium, potassium, calcium
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: sodium, potassium, and calcium (mmol/L)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_transaminases -ALT, AST, GGT, FA
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure:transaminases
Aminotransferase, alanine [ALT, (U/L)]
Aminotransferase, aspartate [AST,(U/L)]
Gamma-glutamyl transpeptidase [GGT,(U/L)]
Alpha fetoprotein[FA,(mcg/L)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_glycated hemoglobin
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: glycated hemoglobin (mmol/mol)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ferritin
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: ferritin (ng/mL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_iron
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: iron (mcg/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_Index of transferrin saturation
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: index of transferrin saturation (%)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_transferrin
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: transferrin (mg/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ vitamin B12
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: vitamin B12 (pg/mL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ folic acid
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: folic acid (ng/mL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ HDL
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: High-density lipoprotein [HDL,(mg/dL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ TSH
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: TSH (mclU/mL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ Total cholesterol (TC)
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: total cholesterol [TC,(mg/dL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ LDL
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: Low-density lipoprotein [LDL,(mg/dL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ albumin
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: albumin (g/dL)
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ triglycerides
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: triglycerides (mg/dL9
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ NT-proBNP
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure:N-Terminal propeptide of BNP[NT-proBNP,(pg/mL)]
Physiological biomarkers_Blood biomarkers_ Complete Blood Cell Count (CBC)_ vitamin D.
Instruments: The blood test. The extraction of the blood sample must be carried out by a qualified professional (Physician or Nurse). For data analysis, the samples will be sent to the laboratory to recounter de sample.
Measure: vitamin D (ng/ml)
Biomechanical biomarkers _ RGB-D camera (depth camera)_Trunk linear acceleration
Instruments: RGB-D camera or depth camera. Kinematic analysis by 3D motion capture.
Measure:
Trunk linear acceleration (m/s2)
Biomechanical biomarkers_ RGB-D camera (depth camera)_Trunk angular displacement
Instruments: RGB-D camera or depth camera. Kinematic analysis by 3D motion capture.
Measure:
Trunk angular displacement (°)
Biomechanical biomarkers _ RGB-D camera (depth camera)_Trunk angular velocity
Instruments: RGB-D camera or depth camera. Kinematic analysis by 3D motion capture.
Measure:
Trunk angular velocity (°/s)
Biomechanical biomarkers_ Shimmer3_Step and stride length
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Step and stride length
Biomechanical biomarkers_ Shimmer3_Step and stride time
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Step and stride time (seg)
Biomechanical biomarkers _ Shimmer3_Step and stride widths stride
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Step and stride widths stride
Biomechanical biomarkers _ Shimmer3_Swing phase time gait
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Swing phase time gait
Biomechanical biomarkers _ Shimmer3_Gait speed (m/s)
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Gait speed (m/s)
Biomechanical biomarkers _ Shimmer3_Stance phase
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Stance phase
Biomechanical biomarkers _ Shimmer3_Step speed and stride.
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Step speed and stride.
Biomechanical biomarkers _ Shimmer3_Step symmetry
Instruments: Inertial sensor (Accelerometer, Gyroscope, and Magnetometer) included in the Shimmer3 instrument.
Measure:
Step symmetry
Imaging biomarkers _Cardiac-Echocardiogram (LVEF)
Instruments: Echocardiogram Measure:Left ventricular Ejection Fraction (%), LVEF
Imaging biomarkers _Cardiac-Echocardiogram (Dilatation and Diameter of the left atrium and left ventricle)
Instruments: Echocardiogram Measure: Dilatation of the left atrium, Dilatation of the left ventricle, Diameter of the left atrium, Diameter of the left ventricle (cm)
Imaging biomarkers _Muscular-Echocardiographic (Muscle Thickness)
Instruments: B-mode ultrasonography device (SonoSite 180 Plus, SonoSite Japan, Tokyo, Japan) Measure: Muscular thickness of the quadriceps rectus muscle ,the diaphragm muscle thickness obtained at the end of inspiration (at total lung capacity; DT-insp) and at resting expiration (at functional residual capacity; DT-exp) through Matlab software (CodigoEco)-[Muscle Thickness]
Imaging biomarkers _Displacement-Echocardiographic (Slide-pL)
Instruments: B-mode ultrasonography device (SonoSite 180 Plus, SonoSite Japan, Tokyo, Japan) Measure: Pleural displacement (Slide-pL, mm) during a complete respiratory cycle through Matlab software (CodigoEco)-[Slide-pL]
Imaging biomarkers_Muscular-Echocardiographic (Fat Thickness)
Instruments: B-mode ultrasonography device (SonoSite 180 Plus, SonoSite Japan, Tokyo, Japan) Measure: Fat thickness of the quadriceps rectus muscle through Matlab software (CodigoEco)-[Fat Thickness]
Imaging biomarkers_Muscular-Echocardiographic (Muscle Echo-Intensity)
Instruments: B-mode ultrasonography device (SonoSite 180 Plus, SonoSite Japan, Tokyo, Japan) Measure: Muscle Echo-intensity of the quadriceps rectus muscle through Matlab software (CodigoEco)- [Muscle His]
Imaging biomarkers_Muscular-Echocardiographic (Fat Echo-Intensity)
Instruments: B-mode ultrasonography device (SonoSite 180 Plus, SonoSite Japan, Tokyo, Japan) Measure: Fat Echo-intensity of the quadriceps rectus muscle through Matlab software (CodigoEco)- [Fat His]
Self-reported_ Borg Rating of Perceived Exertion (RPE)-Borg Scale
Instruments: Borg Rating of Perceived Exertion (RPE)- Borg Scale Measure: The Borg Rating of Perceived Exertion (RPE) is a way of measuring physical activity intensity level. Perceived exertion is how hard you feel like your body is working. It is based on the physical sensations a person experiences during physical activity, including increased heart rate, increased respiration or breathing rate, increased sweating, and muscle fatigue. Although this is a subjective measure, your exertion rating based on a 6 to 20 rating scale, may provide a fairly good estimate of your actual heart rate during physical activity
Self-reported_Sarcopenia Questionnaire (SARC-F)
Instruments: SARC-F questionnaire Measure: It is a simple questionnaire to rapidly diagnose Sarcopenia. It is composed by 5 components: Strength, Assistance to walk, Get up from a chair, Climb stairs and Falls. Scores range from 0 to 10, with 0 to 2 points for each component. A score equal to or greater than 4 could predict sarcopenia and poor results.
Self-reported_abbreviated Comprehensive Geriatric Assessment (aCGA):
Instruments: abbreviated Comprehensive Geriatric Assessment (aCGA): a questionnaire formed by items originating from four different scales.
Measure: 4 instruments such as:
the Geriatric Depression Scale (GDS),
the Mini-Mental State Examination (MMSE),
Activities of Daily Living (ADL) using the Katz index and instrumental activities of daily living (IADL) using the Lawnton & Brody scale.
The score varies from 0 to 30 points, giving 1 point to each of the items of the GDS (4 points in total), 12 to the 3 items from the scale of Lawton & Brody, 8 points to the 4 items from the MMSE and 6 points to the 3 items from the Katz index.