New Stereotactic Frame System for Neurosurgery
Primary Purpose
Parkinson Disease, Essential Tremor, Dystonia
Status
Withdrawn
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
DBS Electrode Implantation using D1 Sterotactic System
Sponsored by
About this trial
This is an interventional device feasibility trial for Parkinson Disease focused on measuring deep brain stimulation, sterotactic surgery, neurological disorders, stereotactic instruments
Eligibility Criteria
Inclusion Criteria:
- Must be adult subjects with medically intractable neurological disorder who have been approved for DBS surgery by the interdisciplinary Mayo DBS committee.
- Competent and willing to provide signed, informed consent to participate in the study.
- Competent and willing to provide written, informed consent to participate in the study.
Exclusion Criteria:
- Pregnant subjects, prisoners, individuals ages less than 18 and any subjects identified as unsuitable for DBS surgery by the Mayo Clinic DBS committee.
- Subjects unable to communicate with the investigator and staff.
- Any health condition that in the investigator's opinion should preclude participation in this study.
Sites / Locations
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
D1 Stereotactic System Assessment
Arm Description
Participants in the clinical study will consist of subjects approved to undergo deep brain stimulation surgery for the treatment of a neurological disorder at Mayo Clinic. Subjects will have a Key secured to their skull for attachment of an MRI-compatible localizer box or D1 stereotactic frame. 3D Euclidian distance error(s), trajectory accuracy(s), operating room time, and comfort level of the system will be assessed.
Outcomes
Primary Outcome Measures
3D Euclidian distance error
3D Euclidian distance error between the MR planned coordinate (XP, YP, ZP) and CT confirmed actual DBS coordinate (XA, YA, ZA) will be calculated. The 3D distance error comparable or lower to conventional system will be accounted as success criteria.
Trajectory accuracy
A trajectory accuracy will be determined by comparing Collar Angle (CA) and Arc Angle (AA) between MR planned angles (CAP and AAP) and CT confirmed actual angles (CAA and AAA). The non-significant difference between MR planned and CT confirmed angles will be accounted as success criteria.
Operating room time
Operating room time will be counted and compared to conventional procedure (using Leksell frame). The average operating room time will be compared between conventional procedure and D1 Stereotactic System procedure. Significantly lower operating room time will be accounted as success criteria
Comfort level questionnaire
Comfort level questionnaire will be given to each subject after DBS surgery and removal of the device to assess their overall experience with device and surgery.
Secondary Outcome Measures
Full Information
NCT ID
NCT04283812
First Posted
February 23, 2020
Last Updated
August 1, 2022
Sponsor
Mayo Clinic
Collaborators
NaviNetics Inc.
1. Study Identification
Unique Protocol Identification Number
NCT04283812
Brief Title
New Stereotactic Frame System for Neurosurgery
Official Title
A Re-attachable Stereotactic Frame System for Clinical Interventive Neurosurgery
Study Type
Interventional
2. Study Status
Record Verification Date
August 2022
Overall Recruitment Status
Withdrawn
Why Stopped
Per PI discretion, study closed and no participants enrolled
Study Start Date
January 2023 (Anticipated)
Primary Completion Date
June 2023 (Anticipated)
Study Completion Date
June 2023 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Mayo Clinic
Collaborators
NaviNetics Inc.
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
This study is designed to demonstrate an in-house developed re-attachable stereotactic system that can markedly reduce the overall deep brain stimulation (DBS) procedure time to greatly facilitate subject access to neurosurgical restorative therapies. Subjects will consist exclusively of individuals who have been approved to undergo deep brain stimulation surgery for the treatment of a neurological disorder at Mayo Clinic - Rochester MN. This study is a quantitative comparative, between-subject study enrolling approximately 10 subjects.
Detailed Description
Aims:
This study will evaluate a new stereotactic device (D1 stereotactic system) designed to address shortcomings of current stereotactic systems by using a novel surface-mounted stereotactic system that is comparatively small, lightweight, user-friendly, and comparable in precision and accuracy to current clinical systems.
Methods:
Subjects will be recruited exclusively from adult subjects with a neurological disease. These subjects will be identified preoperatively from DBS clinical subjects. Each subject will undergo an evaluation by the Mayo Clinic Deep Brain Stimulation Committee (comprised of neurologists, neuropsychologists, psychiatrists, neurosurgeons, and radiologists) to receive a DBS surgery at Mayo Clinic - Rochester for the treatment of a neurological disease. All subjects will be pre-screened against the standard Mayo Clinic inclusion/exclusion criteria for DBS surgery through face-to-face interviews. Once a subject has been identified, the Study Coordinator will contact the subject for interest in participation in the study.
Step-by-Step Schedule:
Skull Anchor Key Attachment Location: St. Mary Hospital - Subject Preparation Room
Superior portion of the head, the hair is clipped off in the area where Skull Anchor Key would be placed. The clipped area and surrounding region is prepped in usual sterile fashion. This begins subject participation in the protocol.
The MR Localizer Box is placed upside down and the Skull Anchor Key is placed within its slot in the MR Localizer Box and screwed in using MR compatible screws.
The apparatus is positioned on the subject head and allowed to rest such that the Skull Anchor Key is midline and the ear bars lie parallel to the external auditory meatus taking caution to prevent the bottom surface of the Skull Anchor Key or the safety caps from becoming non sterile.
The Z value of the ear bars is adjusted such that the ear probes are at same horizontal level as the external auditory meatus. The ear bars are gently pushed into the external auditory meatus on both sides such that it is snug but comfortable to the subject. (NOTE: If required, the Y position of the ear bars may be readjusted at this step in situations such as the anterior N fiducial bars hitting the forehead of the subject).
After confirming accurate initial placement of the MR Localizer Box, the sites of skull screw and pins placement are marked using a surgical pen with the guide Skull Anchor Key which has holes instead of screws and pins acting as reference guide. The MR Localizer Box is then removed and each of the pen marked site receives an injection of local anesthetic.
Following local anesthetic application, the ear bars are removed from the ear while an assistant supports the MR Localizer Box. The MR Localizer Box is gradually lowered to allow the pins to penetrate scalp until it rests on the bone. At this point, titanium self-tapping screws are gently screwed in through the hole on each of the 2 angled legs of the Skull Anchor Key until the Skull Anchor Key is level and secure.
The subject is then transferred to the MR/CT Imaging Facility for target planning.
MRI Acquisition and Target Planning Location: St. Mary Hospital - Neuroradiology Facility
Once in MR suite, the subject rests their head in a custom made MR headrest which sits within the lower portion of RF coil. The headrest holds the axis of MR Localizer Box parallel to the axis of MR gantry and allows the frame to be held securely during the MR imaging.
The subject is positioned in a MR scanner in a supine position.
An anatomical image volume is acquired. The field of view region is adjusted to ensure the MR Localizer Box fiducials are visible in the MR images and then all images are acquired.
The images are then transferred to the surgical planning computer.
Following image acquisition, the images are reviewed by the surgical team to judge whether they are suitable for surgical planning. (If found unsuitable, the imaging and review is repeated.) Once satisfactory images are obtained, the subject is moved to the subject preparation room where the MR Localizer Box is detached from the KEY.
A DBS surgical plan, comprised of the electrode stereotactic target coordinates and an optimal trajectory is created by the navigational software. The plan is documented and shared with the surgical team.
The subject is then transferred to the operating room for DBS electrode implantation.
DBS Electrode Implantation Location: St. Mary Hospital - Operating Room
The subject is shifted to the operating room.
The D1 stereotactic device is attached to the Skull Anchor Key and the X, Y, Z, Arc and Collar angles will be adjusted based on MR planned coordinates.
Standard procedure is followed for making the incision and burr hole, putting in the DBS electrode, electrophysiologic target confirmation (as required) and securing the electrode in place.
A C-arm is then used to obtain a lateral view radiograph to confirm correct placement of the DBS electrode as assessed by the alignment of the tip of the DBS electrode with X-ray reticules on the stereotactic device.
Above steps are repeated for additional DBS electrode insertion.
After securing the last DBS electrode the stereotactic device is removed from the KEY. All DBS electrodes are then coiled and secured under the skin or are tunneled beneath the skin of the scalp and neck for battery placement as currently practiced. All surgical incisions are then sutured.
The CT Localizer Box is attached to the Skull Anchor Key to acquire a post-operative CT scan.
The subject is then transferred to the Neuroradiology Facility for post-operative CT imaging.
CT Confirmation and CT Localizer Box and KEY Removal Location: St. Mary Hospital - Neuroradiology Facility
With the subject in the CT imaging room the subject is positioned supine in the CT scanner to acquire a postoperative anatomical image volume to confirm the placement of the DBS electrode placement using planning software normally used for neurosurgical procedures.
Immediately following the CT scan, the subject is taken to the preparation room for removal of the CT Localizer Box, the Skull Anchor Key, and post-removal treatments. The self-tapping titanium screws are removed and the surgical site is treated appropriately.
Power Statement:
This is a pilot study with a unique subject cohort.
Data Analysis Plan:
The effectiveness of the D1 Stereotactic System in accurately implanting DBS electrodes in adults approved for DBS surgery at Mayo Clinic for treatment of a neurological disease will be evaluated by analyzing the following:
A 3D Euclidian distance error between the MR planned coordinate (XP, YP, ZP) and CT confirmed actual DBS coordinate (XA, YA, ZA) will be calculated. The 3D distance error comparable or lower to conventional system will be accounted as success criteria. Unpaired t-test will be used to determine whether the difference is significantly different or not.
A trajectory accuracy will be determined by comparing Collar Angle (CA) and Arc Angle (AA) between MR planned angles (CAP and AAP) and CT confirmed actual angles (CAA and AAA). The non-significant difference between MR planned and CT confirmed angles will be accounted as success criteria. Paired t-test will be used for 10 patient data.
Operating room time will be counted and compared to conventional procedure (using Leksell frame). The average operating room time will be compared between conventional procedure and D1 Stereotactic System procedure. Significantly lower operating room time will be accounted as success criteria.
Comfort level questionnaire will be given to each subject after DBS surgery and removal of the device to assess their overall experience with device and surgery.
Data Exclusion Criteria: If any surgical plan is changed in operating room (i.e., target coordinate, trajectory), the data will be excluded. However, the change of DBS electrode depth will be accounted as valid data.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Parkinson Disease, Essential Tremor, Dystonia, Tourette Syndrome, Obsessive-Compulsive Disorder
Keywords
deep brain stimulation, sterotactic surgery, neurological disorders, stereotactic instruments
7. Study Design
Primary Purpose
Device Feasibility
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Masking Description
No other parties will be masked
Allocation
N/A
Enrollment
0 (Actual)
8. Arms, Groups, and Interventions
Arm Title
D1 Stereotactic System Assessment
Arm Type
Experimental
Arm Description
Participants in the clinical study will consist of subjects approved to undergo deep brain stimulation surgery for the treatment of a neurological disorder at Mayo Clinic. Subjects will have a Key secured to their skull for attachment of an MRI-compatible localizer box or D1 stereotactic frame. 3D Euclidian distance error(s), trajectory accuracy(s), operating room time, and comfort level of the system will be assessed.
Intervention Type
Device
Intervention Name(s)
DBS Electrode Implantation using D1 Sterotactic System
Intervention Description
Treatment intervention will consist of subjects undergoing Mayo Clinic standard deep brain stimulation surgery specific to their diagnosed neurological disorder consisting of implantation of stimulating electrodes using the D1 stereotactic system.
Primary Outcome Measure Information:
Title
3D Euclidian distance error
Description
3D Euclidian distance error between the MR planned coordinate (XP, YP, ZP) and CT confirmed actual DBS coordinate (XA, YA, ZA) will be calculated. The 3D distance error comparable or lower to conventional system will be accounted as success criteria.
Time Frame
Within 1 month post-DBS surgery.
Title
Trajectory accuracy
Description
A trajectory accuracy will be determined by comparing Collar Angle (CA) and Arc Angle (AA) between MR planned angles (CAP and AAP) and CT confirmed actual angles (CAA and AAA). The non-significant difference between MR planned and CT confirmed angles will be accounted as success criteria.
Time Frame
Within 1 month post-DBS surgery.
Title
Operating room time
Description
Operating room time will be counted and compared to conventional procedure (using Leksell frame). The average operating room time will be compared between conventional procedure and D1 Stereotactic System procedure. Significantly lower operating room time will be accounted as success criteria
Time Frame
Within 1 month post-DBS surgery.
Title
Comfort level questionnaire
Description
Comfort level questionnaire will be given to each subject after DBS surgery and removal of the device to assess their overall experience with device and surgery.
Time Frame
Within 1 month post-DBS surgery.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Must be adult subjects with medically intractable neurological disorder who have been approved for DBS surgery by the interdisciplinary Mayo DBS committee.
Competent and willing to provide signed, informed consent to participate in the study.
Competent and willing to provide written, informed consent to participate in the study.
Exclusion Criteria:
Pregnant subjects, prisoners, individuals ages less than 18 and any subjects identified as unsuitable for DBS surgery by the Mayo Clinic DBS committee.
Subjects unable to communicate with the investigator and staff.
Any health condition that in the investigator's opinion should preclude participation in this study.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Kai Miller, MD, PhD
Organizational Affiliation
Mayo Clinic
Official's Role
Principal Investigator
12. IPD Sharing Statement
Plan to Share IPD
No
Citations:
PubMed Identifier
29288853
Citation
Ben-Haim S, Falowski SM. Evaluation of Patient Perspectives Toward Awake, Frame-Based Deep-Brain Stimulation Surgery. World Neurosurg. 2018 Mar;111:e601-e607. doi: 10.1016/j.wneu.2017.12.122. Epub 2017 Dec 28.
Results Reference
background
PubMed Identifier
17534136
Citation
Bjartmarz H, Rehncrona S. Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation. Stereotact Funct Neurosurg. 2007;85(5):235-42. doi: 10.1159/000103262. Epub 2007 May 25.
Results Reference
background
PubMed Identifier
26227179
Citation
Bot M, van den Munckhof P, Bakay R, Sierens D, Stebbins G, Verhagen Metman L. Analysis of Stereotactic Accuracy in Patients Undergoing Deep Brain Stimulation Using Nexframe and the Leksell Frame. Stereotact Funct Neurosurg. 2015;93(5):316-25. doi: 10.1159/000375178. Epub 2015 Jul 29.
Results Reference
background
PubMed Identifier
30124202
Citation
Edwards CA, Rusheen AE, Oh Y, Paek SB, Jacobs J, Lee KH, Dennis KD, Bennet KE, Kouzani AZ, Lee KH, Goerss SJ. A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model. J Neural Eng. 2018 Dec;15(6):066003. doi: 10.1088/1741-2552/aadb49. Epub 2018 Aug 20.
Results Reference
background
PubMed Identifier
7041006
Citation
Goerss S, Kelly PJ, Kall B, Alker GJ Jr. A computed tomographic stereotactic adaptation system. Neurosurgery. 1982 Mar;10(3):375-9. doi: 10.1227/00006123-198203000-00014.
Results Reference
background
PubMed Identifier
26679880
Citation
Grahn PJ, Goerss SJ, Lujan JL, Mallory GW, Kall BA, Mendez AA, Trevathan JK, Felmlee JP, Bennet KE, Lee KH. MRI-Guided Stereotactic System for Delivery of Intraspinal Microstimulation. Spine (Phila Pa 1976). 2016 Jul 1;41(13):E806-E813. doi: 10.1097/BRS.0000000000001397.
Results Reference
background
PubMed Identifier
6374493
Citation
Kelly PJ, Kall BA, Goerss S. Computer simulation for the stereotactic placement of interstitial radionuclide sources into computed tomography-defined tumor volumes. Neurosurgery. 1984 Apr;14(4):442-8. doi: 10.1227/00006123-198404000-00009.
Results Reference
background
PubMed Identifier
3543519
Citation
Kelly PJ, Sharbrough FW, Kall BA, Goerss SJ. Magnetic resonance imaging-based computer-assisted stereotactic resection of the hippocampus and amygdala in patients with temporal lobe epilepsy. Mayo Clin Proc. 1987 Feb;62(2):103-8. doi: 10.1016/s0025-6196(12)61877-1.
Results Reference
background
PubMed Identifier
23441210
Citation
Knight EJ, Min HK, Hwang SC, Marsh MP, Paek S, Kim I, Felmlee JP, Abulseoud OA, Bennet KE, Frye MA, Lee KH. Nucleus accumbens deep brain stimulation results in insula and prefrontal activation: a large animal FMRI study. PLoS One. 2013;8(2):e56640. doi: 10.1371/journal.pone.0056640. Epub 2013 Feb 18.
Results Reference
background
PubMed Identifier
21160241
Citation
Konrad PE, Neimat JS, Yu H, Kao CC, Remple MS, D'Haese PF, Dawant BM. Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008. Stereotact Funct Neurosurg. 2011;89(1):34-41. doi: 10.1159/000322276. Epub 2010 Dec 15.
Results Reference
background
PubMed Identifier
24933029
Citation
Min HK, Ross EK, Lee KH, Dennis K, Han SR, Jeong JH, Marsh MP, Striemer B, Felmlee JP, Lujan JL, Goerss S, Duffy PS, Blaha C, Chang SY, Bennet KE. Subthalamic nucleus deep brain stimulation induces motor network BOLD activation: use of a high precision MRI guided stereotactic system for nonhuman primates. Brain Stimul. 2014 Jul-Aug;7(4):603-607. doi: 10.1016/j.brs.2014.04.007. Epub 2014 May 2.
Results Reference
background
PubMed Identifier
17489644
Citation
Okun MS, Fernandez HH, Rodriguez RL, Foote KD. Identifying candidates for deep brain stimulation in Parkinson's disease: the role of the primary care physician. Geriatrics. 2007 May;62(5):18-24.
Results Reference
background
PubMed Identifier
24814855
Citation
Wang DD, Lau D, Rolston JD, Englot DJ, Sneed PK, McDermott MW. Pain experience using conventional versus angled anterior posts during stereotactic head frame placement for radiosurgery. J Clin Neurosci. 2014 Sep;21(9):1538-42. doi: 10.1016/j.jocn.2014.02.009. Epub 2014 May 6.
Results Reference
background
Links:
URL
https://www.mayo.edu/research/clinical-trials
Description
Mayo Clinic Clinical Trials
Learn more about this trial
New Stereotactic Frame System for Neurosurgery
We'll reach out to this number within 24 hrs