search
Back to results

Regadenoson Stress-MRI to Identify Coronary Artery Disease in Atrial Fibrillation Patients (RECAD-AF)

Primary Purpose

Atrial Fibrillation, Coronary Artery Disease

Status
Completed
Phase
Phase 2
Locations
United States
Study Type
Interventional
Intervention
Regadenoson MRI
Gadobenate dimeglumine
Sponsored by
University of Utah
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Atrial Fibrillation focused on measuring MRI, Atrial Fibrillation

Eligibility Criteria

18 Years - 100 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

Patients with confirmed persistent or paroxysmal AF and suspected coronary artery disease who will undergo catheterization X-ray angiography

Exclusion Criteria:

  1. Critically ill patients, patients on ventilators patients with hypotension, asthmatics, and other patients whose medical care or safety may be compromised from undergoing an MRI examination will be excluded.
  2. Patients with claustrophobia will also be excluded since MRI is conducted in a closed environment.
  3. Patients with contraindications to MRI (pacemaker, metal implants).
  4. Pregnant subjects (or women who may become pregnant), minors, and prisoners will be excluded from this study.
  5. Subjects are over 60 or have any suspicion of abnormal kidney function (a blood test to determine Glomerular filtration rate (GFR) will be performed prior to imaging. Subjects with GFR<30 will be excluded from the study. This is standard practice for clinical scans in Radiology due to the extremely small but not negligible relationship between gadolinium contrast agent and nephrogenic systemic fibrosis in patients with severely impaired renal function.

Sites / Locations

  • University of Utah

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Regadenoson MRI

Arm Description

Participants with AF receiving regadenoson stress MRI, using Gadobenate dimeglumine

Outcomes

Primary Outcome Measures

Sensitivity of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Determination of sensitivity of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.
Specificity of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Determination of specificity of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.

Secondary Outcome Measures

Accuracy of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Determination of accuracy of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Accuracy is the percentage of correctly classified subjects (true positive + true negative) among all subjects (true positive + true negative + false positive + false negative). Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.

Full Information

First Posted
October 2, 2012
Last Updated
November 17, 2017
Sponsor
University of Utah
search

1. Study Identification

Unique Protocol Identification Number
NCT01710254
Brief Title
Regadenoson Stress-MRI to Identify Coronary Artery Disease in Atrial Fibrillation Patients
Acronym
RECAD-AF
Official Title
Detection of Coronary Artery Disease in Patients With Atrial Fibrillation Using Regadenoson Stress MRI
Study Type
Interventional

2. Study Status

Record Verification Date
November 2017
Overall Recruitment Status
Completed
Study Start Date
January 2013 (undefined)
Primary Completion Date
October 2016 (Actual)
Study Completion Date
October 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
University of Utah

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Atrial fibrillation (AF) is growing into an epidemic affecting 1 in 4 adults. There is a need for research to elucidate the prevalence of ischemic cardiomyopathy in patients diagnosed with AF. The objective of this study is to demonstrate the utility of MRI in assessment of coronary artery disease. The specific objective is to demonstrate sensitivity/specificity comparable to that reported in meta-analyses of non-AF patients and adenosine (90% /80%) in an AF population using the time-efficient vasodilator regadenoson that requires only a single intravenous (IV).
Detailed Description
Scientific Background/Rationale: Atrial fibrillation (AF) is a large and growing healthcare problem worldwide. Over 7 million people in the U.S. and Europe currently suffer from atrial fibrillation, and this number is expected to double before 2050. The lifetime risk of AF is high: ~24% at age 40, and this risk remains fairly constant at older ages, with 22% lifetime risk at age 80 [1]. AF significantly increases the risk of stroke and mortality, and can greatly limit quality of life. Little research has been done on AF and ischemic cardiomyopathy, though it is a relatively common co-morbidity. CT found increased prevalence (41% vs 27%) of coronary artery disease (CAD) in patients with AF compared to patients with similar pre-test risk but no AF [2]. AF patients with a positive SPECT scan for CAD have a worse prognosis for cardiac events than patients with positive SPECT but without AF [3]. It was recently reported that in a study of 253 AF patients, that AF patients with positive SPECT studies had a very high number of false positives - only 15% of patients had significant CAD by angiography (compared to 67% in the control group) [4, 5]. Just over half of the patients were in sinus rhythm at SPECT, but since similar numbers of positives were seen in each half, the authors did not feel that imaging during AF was the cause of the poor specificity. Use of MRI for assessment of CAD is a growing area that entails no radiation exposure to the patient. Advances in MRI have made it possible to accurately detect CAD, either as well or better than SPECT in unselected populations [6, 7]. However, adoption of MRI myocardial perfusion scans has been limited in part due to the challenges associated with the use of adenosine. Adenosine requires starting a second IV, and to use either a special expensive MRI-compatible infusion pump to deliver the drug, or long lengths of tubing to run to a pump outside the scanner room. Neither solution is ideal, and regadenoson would not require any such pumps or the starting of a second IV. Here the investigators propose to determine the sensitivity/specificity for dynamic contrast-enhanced myocardial perfusion MRI with the vasodilator regadenoson in a subpopulation of patients - those with atrial fibrillation. The investigators have a great deal of experience with stress and rest myocardial perfusion MRI. In a preliminary study imaging three patients with AF that then went to X-ray angiography (cath), two of the three subjects had significant stenoses by cath, and one did not. This agreed with the regadenoson stress perfusion MRI findings. These MRI acquisitions were performed on a Siemens Verio MRI scanner. The Verio operates at twice the magnetic field strength (3 Tesla, or 3T) of most MRI scanners, which operate at 1.5T. The higher magnetic field offers images with significantly less noise (almost twice the signal-to-noise ratio). Objective: To demonstrate sensitivity/specificity comparable to that reported in meta-analyses of non-AF patients and adenosine (90%/80% [6, 7]), in an atrial fibrillation population while using the time-efficient vasodilator regadenoson that requires only a single IV. Study Design: This will be a prospective, open-label, comparative trial using MRI. Non-invasive MRI measurements of resting flow and flow at regadenoson stress will be obtained in each subject during a one hour MRI exam using our advanced MRI acquisition techniques. Sensitivity/specificity of regadenoson stress MRI will be determined using x-ray angiography as the standard. X-ray angiography will be done as standard-of-care, and is not an intervention of this clinical trial. Study Procedure: Each subject will undergo a single MRI scanning session. Caffeine will be stopped 12 hours prior to the procedure. One IV will be started and subjects positioned in the scanner. Resting perfusion with Multihance Gd-BOPTA contrast agent will be performed first. The perfusion acquisition acquires 3-6 short axis slices each heartbeat and lasts for one minute. Then a standard regadenoson injection of 400ug/5cc will be given and MR imaging performed with a Gd-BOPTA contrast agent bolus 60-100 seconds later [9] [10].

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Atrial Fibrillation, Coronary Artery Disease
Keywords
MRI, Atrial Fibrillation

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Phase 2
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
30 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Regadenoson MRI
Arm Type
Experimental
Arm Description
Participants with AF receiving regadenoson stress MRI, using Gadobenate dimeglumine
Intervention Type
Drug
Intervention Name(s)
Regadenoson MRI
Other Intervention Name(s)
Lexiscan
Intervention Description
AF patients will be provided with a regadenoson stress MRI to see if coronary artery disease can be detected with more sensitivity /specificity.
Intervention Type
Drug
Intervention Name(s)
Gadobenate dimeglumine
Other Intervention Name(s)
Gd-BOPTA, Multihance
Intervention Description
Resting perfusion with Multihance Gd-BOPTA contrast agent will be performed first, then a regadenoson injection will be given and MR imaging performed with a Gd-BOPTA contrast agent bolus 60-100 seconds later.
Primary Outcome Measure Information:
Title
Sensitivity of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Description
Determination of sensitivity of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.
Time Frame
one MRI, up to 1 hour
Title
Specificity of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Description
Determination of specificity of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.
Time Frame
one MRI, up to 1 hour
Secondary Outcome Measure Information:
Title
Accuracy of Regadenoson Stress-MRI for Detection of Coronary Artery Disease (CAD)
Description
Determination of accuracy of Regadenoson stress-MRI in the detection of CAD, using x-ray angiography as the standard. Accuracy is the percentage of correctly classified subjects (true positive + true negative) among all subjects (true positive + true negative + false positive + false negative). Perfusion images interpreted by three blinded readers as normal or abnormal; majority results of the three blinded readers are reported.
Time Frame
one MRI, up to 1 hour

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
100 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients with confirmed persistent or paroxysmal AF and suspected coronary artery disease who will undergo catheterization X-ray angiography Exclusion Criteria: Critically ill patients, patients on ventilators patients with hypotension, asthmatics, and other patients whose medical care or safety may be compromised from undergoing an MRI examination will be excluded. Patients with claustrophobia will also be excluded since MRI is conducted in a closed environment. Patients with contraindications to MRI (pacemaker, metal implants). Pregnant subjects (or women who may become pregnant), minors, and prisoners will be excluded from this study. Subjects are over 60 or have any suspicion of abnormal kidney function (a blood test to determine Glomerular filtration rate (GFR) will be performed prior to imaging. Subjects with GFR<30 will be excluded from the study. This is standard practice for clinical scans in Radiology due to the extremely small but not negligible relationship between gadolinium contrast agent and nephrogenic systemic fibrosis in patients with severely impaired renal function.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Brent Wilson, MD
Organizational Affiliation
University of Utah
Official's Role
Principal Investigator
Facility Information:
Facility Name
University of Utah
City
Salt Lake City
State/Province
Utah
ZIP/Postal Code
84132
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
15313941
Citation
Lloyd-Jones DM, Wang TJ, Leip EP, Larson MG, Levy D, Vasan RS, D'Agostino RB, Massaro JM, Beiser A, Wolf PA, Benjamin EJ. Lifetime risk for development of atrial fibrillation: the Framingham Heart Study. Circulation. 2004 Aug 31;110(9):1042-6. doi: 10.1161/01.CIR.0000140263.20897.42. Epub 2004 Aug 16.
Results Reference
background
PubMed Identifier
19808575
Citation
Nucifora G, Schuijf JD, Tops LF, van Werkhoven JM, Kajander S, Jukema JW, Schreur JH, Heijenbrok MW, Trines SA, Gaemperli O, Turta O, Kaufmann PA, Knuuti J, Schalij MJ, Bax JJ. Prevalence of coronary artery disease assessed by multislice computed tomography coronary angiography in patients with paroxysmal or persistent atrial fibrillation. Circ Cardiovasc Imaging. 2009 Mar;2(2):100-6. doi: 10.1161/CIRCIMAGING.108.795328. Epub 2009 Jan 26.
Results Reference
background
PubMed Identifier
15337220
Citation
Abidov A, Hachamovitch R, Rozanski A, Hayes SW, Santos MM, Sciammarella MG, Cohen I, Gerlach J, Friedman JD, Germano G, Berman DS. Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol. 2004 Sep 1;44(5):1062-70. doi: 10.1016/j.jacc.2004.05.076.
Results Reference
background
PubMed Identifier
20022875
Citation
Smit MD, Tio RA, Slart RH, Zijlstra F, Van Gelder IC. Myocardial perfusion imaging does not adequately assess the risk of coronary artery disease in patients with atrial fibrillation. Europace. 2010 May;12(5):643-8. doi: 10.1093/europace/eup404. Epub 2009 Dec 17.
Results Reference
background
PubMed Identifier
17903634
Citation
Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2007 Oct 2;50(14):1343-53. doi: 10.1016/j.jacc.2007.06.030. Epub 2007 Sep 17.
Results Reference
background
PubMed Identifier
20482819
Citation
Hamon M, Fau G, Nee G, Ehtisham J, Morello R, Hamon M. Meta-analysis of the diagnostic performance of stress perfusion cardiovascular magnetic resonance for detection of coronary artery disease. J Cardiovasc Magn Reson. 2010 May 19;12(1):29. doi: 10.1186/1532-429X-12-29.
Results Reference
background
PubMed Identifier
15493698
Citation
Ablitt NA, Gao J, Keegan J, Stegger L, Firmin DN, Yang GZ. Predictive cardiac motion modeling and correction with partial least squares regression. IEEE Trans Med Imaging. 2004 Oct;23(10):1315-24. doi: 10.1109/TMI.2004.834622.
Results Reference
background
Citation
S. E. Litwin, J. Fluckiger, L. Chen, T. H. Kim, N. Pack, B. Matthews, C. McGann, R. Jiji, et al. Does fixed-dose regadenoson induce comparable myocarial perfusion reserve in patients of widely varying body size? A quantitative MRI study. American Heart Association, chicago, 2010.
Results Reference
background
Citation
O. J. Booker, P. Bandettini, P. Kellman, J. Wilson, S. Leung, S. Vasu, S. Shanbhag, J. Henry, et al. Time resolved measure of coronary sinus flow following regadenoson administration. Journal of cardiovascular magnetic resonance, 13(1): O74, 2011.
Results Reference
background
PubMed Identifier
10323817
Citation
Harper R, Reeves B. Reporting of precision of estimates for diagnostic accuracy: a review. BMJ. 1999 May 15;318(7194):1322-3. doi: 10.1136/bmj.318.7194.1322. No abstract available.
Results Reference
background
PubMed Identifier
28528431
Citation
Bieging ET, Haider I, Adluru G, Chang L, Suksaranjit P, Likhite D, Shaaban A, Jensen L, Wilson BD, McGann CJ, DiBella E. Rapid rest/stress regadenoson ungated perfusion CMR for detection of coronary artery disease in patients with atrial fibrillation. Int J Cardiovasc Imaging. 2017 Nov;33(11):1781-1788. doi: 10.1007/s10554-017-1168-1. Epub 2017 May 20.
Results Reference
derived

Learn more about this trial

Regadenoson Stress-MRI to Identify Coronary Artery Disease in Atrial Fibrillation Patients

We'll reach out to this number within 24 hrs