Smartphone Electrocardiogram for Recording Atrial Fibrillation After a Cerebral Ischemic Event (SMART-AF)
Stroke, Atrial Fibrillation
About this trial
This is an interventional diagnostic trial for Stroke focused on measuring Stroke, Atrial Fibrillation, Smartphone ECG
Eligibility Criteria
Inclusion Criteria:
i. Age 55 years or older. ii. Diagnosis of the index event made by neurologist or general physician of an acute ischemic stroke or TIA (WHO definition) of undetermined etiology occurring within the previous 6 months (180 days). The event must be either:
- An ischemic stroke confirmed by neuroimaging; or
- A transient ischemic attack, defined as involving a focal unilateral motor deficit, speech/language deficit or hemianopia, with symptom duration <24 hours (note: amaurosis fugax/ transient monocular blindness, pure sensory spells, isolated vertigo spells, etc. do not qualify for enrolment given the potential for misdiagnosis of such events).
iii. Patient meets the following:
- At least one 12-lead ECG has already been obtained as part of the routine clinical post-stroke/TIA work up, and not ECGs have shown any episodes of AF or atrial flutter.
- A Holter monitor has already been obtained as part of the routine clinical post-stroke/TIA work-up, and does not show any episodes of AF or atrial flutter ≥30seconds.
iv. The patient is being actively investigated for the etiology of the stroke/TIA event and additional cardiac monitor is desired to screen further for the possibility of AF or atrial flutter.
v. The following diagnostic test have already been completed as part of clinical routine post-stroke/TIA:
- Brain imaging with CT or MRI
- Vascular imaging of the extracranial and intracranial circulation with either CT angiography or MRI angiography to exclude significant large vessel occlusion disease as the most likely mechanism for index ischemic event (carotid Doppler ultrasound is acceptable for those presenting with anterior circulation ischemic events).*
- Transthoracic (or transesophageal) echocardiography to exclude thrombus or other structural heart disease that in the opinion of the investigator is the most likely cause for the stroke/TIA events.* *(if a baseline investigation cannot be obtained clinically after the index event and prior to study enrolment, then it is acceptable for study purposes for investigations to be obtained after patient enrolment into the study but prior to the 90-day follow-up visit.) vi. Informed consent from the patient (or from a legally authorised representative if the patient is not competent, due to stroke-related cognitive impairment, aphasia, or anosognosia).
vii. The patient is expected to survive at least 12 months.
Exclusion Criteria:
- i. Any previously documented atrial fibrillation or atrial flutter (a remote history of transient AF during perioperative period is not exclusionary).
ii. Exclusively retinal stroke or retinal TIA event. iii. A most responsible etiological diagnosis for the qualifying stroke/TIA event has already determined i.e. cervicocephalic artery dissection, venous sinus thrombosis, hypercoagulable states, or other known cause.
iv. Planned carotid endarterectomy within 90 days. v. Any finding on echocardiography for which there is already an evidence-based indication for long-term anticoagulation (e.g. mechanical heart valve, thrombus, etc) vi. Inability to use the AliveCor smartphone ECG monitor upon enrolment into the study (if patient is randomised into interventional group).* vii. Participating in a clinical trial involving investigational medication. viii. Endocarditis. ix. Pregnancy.
Sites / Locations
- SarawakHC
Arms of the Study
Arm 1
Arm 2
No Intervention
Active Comparator
24 Hour Holter
Smartphone ECG
Patients who are randomised to the 24 Hour Holter monitoring will be contacted within one month from randomisation. The repeat 24 Hour Holter result will be explained to the patient at the end of 30-day follow-up.
Patients who are randomised to the 30-day smartphone ECG monitoring will be contacted within one month from randomisation. Patients will be taught on how to use the smartphone ECG monitoring. Patients are required to monitor their ECG 3 times a day for 30 days. Patients will be contacted during the monitoring period to assess for compliance and to ensure that the recording is done correctly.