BIOTRONIK Conduction System Pacing With the Solia Lead
BradycardiaAtrioventricular Block2 moreThe purpose of the BIO-CONDUCT study is to demonstrate the safety and effectiveness of the BIOTRONIK Solia S pacing lead when implanted in the left bundle branch (LBB) area. Safety will be assessed by evaluating serious adverse device effects that occur through 3 months post-implant. Efficacy will be assessed by evaluating implant success rate.
Moderato System in Patients With Hypertension
HypertensionResistant to Conventional Therapy1 moreThe purpose of this double blind randomized study is the evaluation of the safety and efficacy of the Moderato System. The Moderato implantable pulse generator is indicated for patients who have hypertension and also require a dual chamber pacemaker in order to reduce their blood pressure. In this amended CS-03 protocol Version 3.0, the study will evaluate the safety and efficacy in a randomized, double-blind study following active treatment vs. a control patient population for a period of 3 month for efficacy and 12 months for safety (In comparison to 6 months for patients under protocol CS-03 Ver 1.1, NCT02837445). The device will be considered to have a clinical effectiveness with regard to its anti-hypertension function if there is a statistically significant and clinically meaningful reduction in mean 24-hour ambulatory systolic blood pressure in the treatment group compared to the control group. The primary efficacy endpoint will be evaluated 3 months after randomization. The Primary safety analysis will compare the treatment and the control after 12 months of treatment.
Moderato System: A Double-Blind Randomized Trial Ver 1.1
Hypertension Resistant to Conventional TherapyBradycardia1 moreThe purpose of this double blind randomized study is the evaluation of the safety and efficacy of the Moderato System. The Moderato implantable pulse generator is indicated for patients who have hypertension and also require a dual chamber pacemaker in order to reduce their blood pressure. The primary objectives of this study are to provide evidence of safety and clinical efficacy of the anti-hypertensive effects of the Moderato System. This will be accomplished by evaluating changes in blood pressure in an active treatment vs. a control patient population for a period of 6 months. The device will be considered to have a clinical effectiveness with regard to its anti-hypertension functions if there is a statistically significant and clinically meaningful reduction in mean 24-hour ambulatory systolic blood pressure in the treatment group compared to the control group.
Physiological vs Right Ventricular Pacing in Patients With Normal Ventricular Function Post-TAVI...
Transcatheter Aortic Valve ImplantationPhysiological Pacing2 moreSingle-center randomized trial in patients with pacing indication (AV block) after TAVI (transfemoral aortic valve implantation) and LVEF> 50%, that aims to study the percentage of patients who improve at 12 months in a combined clinical endpoint.
Left Bundle Branch Area Pacing in Patients After TAVR
Aortic Valve StenosisAV Block1 moreProspective, randomized, single center clinical trial to compare the outcome of left bundle branch area pacing versus right ventricular apical pacing in patients with higher degree atrio-ventricular block and a normal left ventricular function after transcatheter aortic valve replacement.
Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block...
Aortic Valve DiseaseConduction DisturbancesThe purpose of this study is to determine the incidence and predictors of high degree or complete atrioventricular block (AVB) (paroxysmal or persistent) in patients with new-onset persistent left bundle branch block (NOP-LBBB) following transcatheter aortic valve implantation (TAVI) and to evaluate the usefulness of the Reveal LINQ® insertable Cardiac Monitor (ICM) (Medtronic, Inc., Minneapolis, USA) for the detection of significant arrhythmias in patients with NOP-LBBB following TAVI.
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
Atrioventricular BlockSecond and Third Degree2 moreThe aim of the study is to demonstrate that conduction system pacing (CSP) can preserve a normal ventricular function compared to right ventricular apical pacing (RVAP) in patients with pre-implant preserved left ventricular ejection fraction (LVEF) and a high burden of expected ventricular pacing due to atrioventricular conduction block (AV block). After informed consent signature, patients with high degree AV block and normal LVEF will be randomized to permanent pacemaker stimulation with CSP vs RVAP. All the patients have a complete evaluation before the procedure and at 3 and 6 months follow-up.
Predictive Value of Pre-TAVI Infrahissian Conduction Time in the Occurrence of Complete Atrioventricular...
Aortic StenosisSevereThe purpose of the study is implantation of a Pacemaker at 30 days for occurrence of a high-grade conduction disorder per- or post-procedure (yes/no)
Left Bundle Branch Pacing Versus Right Ventricular Pacing in Patients With Atrioventricular Block...
AVB - Atrioventricular BlockAlthough emerging evidence demonstrated that left bundle branch pacing (LBBP) is a promising alternative for patients with either a bradycardia or a heart failure pacing indication. However, a direct comparison of the safety, efficacy and LV systolic synchrony between LBBP and RVP regimens was rare. In this study, the investigators aim to conduct a comparison of the safety and effectiveness performance between these two pacing methods for patients with atrioventricular block (AVB). The investigators focused on AVB patients undergoing permanent pacemaker implantations from the 1st of January 2018 to the 18th of November 2021 at West China Hospital.
Safety and Effectiveness of Left Bundle Branch Pacing in Patients With Cardiac Dysfunction and AV...
Atrioventricular BlockSecond and Third Degree2 moreThis study is a multicenter, prospective, randomized study to assess if cardiac dysfunction patients with LVEF <50% and the estimated ventricular pacing percentage >40% with LBBP have the non-inferior safety and efficacy than CRT on patients' cardiac function and prognosis