search

Active clinical trials for "Hypotension"

Results 281-290 of 875

The Effect of iv Ondansetron on Reducing Hypotension Due to BCIS in Total Knee Prosthesis Surgery...

Bone Cement Syndrome

Bone cement implantation syndrome (BCIS) is a complication associated with the implantation of polymethylmethacrylate bone cement. Hypoxia, hypotension, and/or unexpected loss of consciousness often result from cementation, prosthetic placement, joint reduction, or tourniquet removal; It is a major cause of intraoperative and postoperative morbidity and mortality. Therefore, reducing the occurrence and severity of BCIS is an important issue. BCIS is mainly known for its association with hip hemiarthroplasty, total hip arthroplasty (TKA), and vertebroplasty, but is also seen during total knee arthroplasty (TKA). The incidence and associated mortality of BCIS has been investigated only in cemented hemiarthroplasty after displaced femoral neck fractures and in operations performed with cemented TCA and hemiarthroplasty in cancer patients. To our knowledge, the incidence associated with BCIS (compared to hemiarthroplasty or TKA), associated factors, and mortality for other hips, knee, or shoulder arthroplasty is not yet known. Little is known about the incidence, mortality risk, and factors associated with the development of BCIS during hip hemiarthroplasty and cemented arthroplasty procedures other than primary TKA. The pathophysiology of BCIS is unclear. The first theories focused on circulating MMA monomers; however, recent evidence suggests an embolism-mediated model. Other additional theories focus on the role of histamine release, complement activation, and finally the multimodal possibilities of all these factors together. Ondansetron, a 5-hydroxytryptamine 3 (5-HT3) receptor antagonist, has been given preoperatively and intraoperatively to block serotonin-induced pulmonary vasoconstriction. This study aimed to investigate whether blocking type 3 serotonin receptors with intravenous ondansetron would reduce hypotension due to bone cement syndrome in patients undergoing TKA under combined spinal-epidural anesthesia.

Not yet recruiting15 enrollment criteria

Timing of Intradialytic Exercise and Its Impact on Intradialytic Hypotension

Intradialytic HypotensionHemodialysis-Induced Symptoms

The objective of this study is to compare the rate of low blood pressure events (Intradialytic Hypotension: IDH) when intradialytic exercise is performed in the first half of the hemodialysis (HD) session as compared to that when intradialytic exercise is performed in the second half of the HD session. The investigators expect that there will be little to no difference in occurrence of IDH episodes between the two time periods based on the experience of the 3 centres and imaging studies of the heart with exercise in HD.

Completed2 enrollment criteria

Determination of the Optimal Dose of Ephedrine in Intraoperative Arterial Hypotension of Newborns...

Intraoperative Arterial HypotensionInfant1 more

The incidence of arterial hypotension under general anesthesia using sevoflurane is particularly high in newborns and infants up to 6 months of age. A decrease of 20% of the initial mean blood pressure (mBP) is the definition of significant arterial hypotension in adults and children. In adults, intraoperative arterial hypotension is associated with an increase of intraoperative mortality and a certain neurological morbidity. In infants under 6 months of age, neurological disorders have been reported following general anesthesia. Neurotoxicity of hypnotics is often incriminated as should be the episodes of arterial hypotension. Current management of hypotension uses vascular filling with crystalloids and vasopressive amines in second intention. Dopamine is the most frequently used amine. Ephedrine can also be used. Ephedrine is particularly interesting because of its action on both α and β receptors and its mode of administration: one dose and peripheral access. Only one study is available in children from birth to adulthood; it demonstrates a lower hemodynamic response in infants than in adults, when administered a low dose of Ephedrine (0.1 to 0.2 mg/kg). A recent retrospective cohort suggests an under efficacy of low doses and the use of higher doses than those recommended. The primary objective is to determine the optimal dose of ephedrine (dose of ephedrine associated with a difference of proportion of newborns/infants in therapeutic success of 55%) compare to the reference dose of 0.1mg/kg as a first line treatment of intraoperative arterial hypotension. Secondary objectives: Return to a mBP superior to 38mmHg post Ephedrine administration. To assess occurrence of hypoxemic events during anesthesia. To assess tolerance of ephedrine. One hundred and twenty newborn and infants up to 6 months of age will be recruited in 3 sites of the Rhone Alpes Auvergne area over 24 months.

Completed13 enrollment criteria

HES Patch Versus Blood Patch

Intracranial Hypotension

The injection of autologous blood Blood Patch (BP) into the epidural space is the standard treatment for headache associated with intracranial hypotension. It provokes cerebral vasoconstriction. It is cons-indicated in a number of situations (HIV positive, fever, sepsis, leukemia). The purpose of this study is to evaluate another technique using a patch made by injecting an epidural hydroxyethylstarch solution (HES 130, 0.4, 6%) instead of blood patch. This alternative technique is simple to implement and does not have some of the specific blood pressure contra-indications. The study aims at comparing the "Blood Patch" group versus the "HES Patch" in terms of clinical efficacy , tolerance, satisfaction of the anesthetist, ease of implementation and effect of the injection of epidural anesthesia on cerebral blood flow within 24 hours.

Completed12 enrollment criteria

NOX-100 for Preventing Hypotension During Hemodialysis

Hypotension

This study is designed to evaluate the safety, tolerability and efficacy profile of NOX-100 to reduce intradialytic hypotension (IDH) in patients undergoing chronic hemodialysis (HD).

Completed15 enrollment criteria

Optimal VAsopressor titraTION Pilot Randomized Controlled Trial

HypotensionShock

The purpose of this research study is to determine if it is better to give vasopressors to patients to maintain a higher blood pressure target versus a lower blood pressure target. This study is important because the information we find out will help us know how best to administer vasopressors in patients with shock in the ICU.

Completed13 enrollment criteria

The Effect of Intravenous Prehydration on the Hemodynamic Status of Healthy Parturients Undergoing...

Hypotension

Regional anesthesia (spinal, epidural) is considered the method of choice for anesthesia obstetric deliveries because of the ability to use fewer drugs, a more direct experience of childbirth and the capability to provide excellent postoperative analgesia. However, the incidence of hypotension after spinal anesthesia for cesarean delivery is high and can lead to maternal and fetal morbidities. Certain interventions may reduce the incidence and severity of spinal anesthesia induced hypotension, including the use of vasopressors and intravenous pre- or co-hydration using different types of volume expanders; crystalloid or colloid solutions. Such interventions aim to increase maternal cardiac output, which is the key in attenuating the hypotensive response to spinal anesthesia. The primary purpose of this study is to compare the efficacy of intravenous prehydration (preloading) of healthy parturients scheduled for caesarean section with either a crystalloid (Ringer's lactated) or colloid solution (HES 130/0.42) in the prevention of hypotension after spinal anesthesia. The FloTrac/VigileoTM device provides continuous monitoring of maternal cardiac output by employment of a minimally invasive technique based on arterial pulse contour analysis. Assessment of maternal hemodynamic status using the FloTrac/VigileoTM constitutes a secondary outcome. Other secondary outcomes are total amount of vasopressors used, neonatal outcome, intraoperative side effects and maternal satisfaction scores.

Completed18 enrollment criteria

Isometric Handgrip Home Training to Lower Blood Pressure in Hypertensive Older adulTs

Hypertension

This Study evaluates the effect of 20 weeks of isometric handgrip (IHG) home training in adults aged 50 years or more. Half of the participants will serve as a control group and will only receive hypertension-guidelines on lifestyle changes.

Completed8 enrollment criteria

Preloading to Prevent Hypotension During Cesarean Section

Obstetric Anesthesia Problems

Whether the usage of non-invasive arterial blood pressure monitor to guide fluid therapy in caesarean section can effectively reduce the incidence of hypotension and fetal complications.

Completed8 enrollment criteria

Interest of Intravenous Ondansetron in the Prevention of Spinal Anaesthesia-induced Hypotension...

Hypotension

The intravenous injection of 8mg of ondansetron (a serotonin type 3 receptor antagonist) before spinal anaesthesia for caesarean section, leads to a smaller reduction in systolic arterial pressure (SAP). The expected results are a decrease in the frequency and severity of hypotension, thus leading to improved comfort for the mother and decreased maternal and foetal morbidity. Indeed, episodes of hypotension are responsible for impaired foeto-placental circulation, with sometimes severe consequences for neonates. It has been established that episodes of hypotension alter foetal pH. Investigators therefore hope to see a smaller reduction in SAP in the ondansetron group, and show a benefit for the infant. One of the objectives of this study is also to observe a decrease in the quantity of vasopressors used and thus to avoid the adverse effects of their use in high doses. The expected results are thus an improvement in haemodynamic stability during spinal anaesthesia for caesarean section. The originality of this project lies in the use of a CNAP monitor (Continuous Non-invasive Arterial Pressure) as the collection of haemodynamic data will allow greater precision with the continuous measurement of AP, as well as a study of maternal cardiac output.

Terminated13 enrollment criteria
1...282930...88

Need Help? Contact our team!


We'll reach out to this number within 24 hrs