Patient Satisfaction and Visual Function Following Implantation of Trifocals or Extended Range of...
CataractCataract surgery is a fast evolving refractive procedure, which aims to restore vision. The majority of intraocular lens (IOL) implants following cataract surgery are monofocal IOLs, which have been designed to improve distance vision by replacing the lens diopter power with a single focal point. Monofocal IOLs have been associated with very few complications related to the material or the technology. However, after the surgery patients are spectacle dependent for near and intermediate tasks. This, in turn, has decreased the patient's post-operative satisfaction and quality of life. Multifocal intraocular lenses (IOLs) were introduced into the market in the 1980s. This type of IOLs provides clear distance and near vision, which affects the quality of life and visual expectations of the patients who receive them. Studies have indicated higher levels of patient's satisfaction with regards to distance and near vision after the implantation of multifocal lenses. With Multifocal IOLs; however, patients are still spectacle dependent for intermediate tasks such as computer work. The recent development of trifocal IOLs has been found to provide optimal near, intermediate, and distance visual performances; decrease spectacle dependence; and increase patient satisfaction.AcrySof®IQ PanOptix™ (PanOptix) was introduced into the market in 2015 with a design that allows the IOL to provide optimal near, intermediate, and distance visual performances; decrease spectacle dependence; and increase patient satisfaction. Despite the benefits of corrected visual acuity at multiple distances, multifocal and/or trifocal IOLs are associated with certain disadvantages, including contrast sensitivity loss, dysphotopsia, halos and glare, which account for over a third of the justifications used for IOL model replacement. Dysphotopsia is the result of light reflecting off the intraocular lens (IOL) onto the retina which causes a variety of visual symptoms that are expressed in a positive or a negative form. Positive dysphotopsia refers to bright artifacts that are noticed in only certain lighting conditions, such as glare and halos. Negative dysphotopsia refers to the formation of a barrier, which prevents light from reaching the retina. The result of the negative form of dysphotopsia is the formation of shadows that are often in the temporal visual field. In 2014, the extended range of vision TECNIS Symfony®IOL (Symfony), with new optical technology using a proprietary achromatic diffractive echelette design, received a CE Mark. However, it was not until 2016 that this IOL became the first extended depth of focus (EDF) IOL to gain approval by the U.S. Food and Drug Administration. This new optical technology corrects the corneal chromatic aberration for enhanced contrast sensitivity, generating a continuous vision for distance through intermediate into near with low incidence of halos and glare. Despite the benefits of EDF IOLs, Monaco et al. conducted a study in Italy and indicated that both PanOptix and Symfony IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the PanOptix IOL may be better for patients with near-vision requirements. A few studies in the literature have evaluated the performance of the PanOptix and Symfony IOLs in Europe. Our current study would add great value to the literature since to the best of our knowledge; this is the first study to address the same IOLs in North America. Cataract surgery expectations are continuously rising, and in an effort to maximize patient satisfaction post-operatively, the appropriateness of a patient for a particular IOL implantation should be evaluated carefully during the pre-operative assessment. Therefore, further research is warranted to evaluate patient satisfaction with both PanOptix and Symfony IOLs. The purpose of this study is to compare the visual outcomes and the subjective satisfaction results between patients implanted with PanOptix and Symfony IOLs.
Influence of Different Tamponade Eyes on IOL-capsular Complex
CataractVitreoretinal AbnormalityCataract and vitreoretinal diseases often occur simultaneously or cataract is a predictable consequence of vitreoretinal surgery.A combined surgery called phacovitrectomy, has been proved to be comparably safe and effective compared with vitrectomy alone. For fundus surgeons, silicone oil(SO),gas and balanced saline solution are frequently-used intravitreal tamponade mediums for retinal repair after vitrectomy. There are many factors that may affect how the lens changes position after the operation including the different intravitreal tamponade materials and different IOL types. This study was designed to evaluate the differences of IOL position and capsule bending between Silicone oil filled eyes,gas filled eyes, balanced saline solution filled eyes and normal eyes. The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant because of poor post-surgery visual quality. Currently, there is no literature guidance to compare the results of phacovitrectomy combined various types of intravitreal tamponade materials in patients using CASIA2. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.
Safety and Effectiveness of Drop-free Small Incision Cataract Surgery
CataractOcular Inflammation2 moreThis is a randomized control trial comparing the effects of subconjunctival triamcinolone administration during surgery to topical prednisolone drops on the development of post-operative inflammation and macular edema in manual small incision cataract surgery.
Objective Measurements of the Opacification of the Lens After Vitrectomy
VitrectomyCataractCataract is the opacification of the lens. Usually cataract occurs slowly, causing progressive vision loss over several months or years. In ophthalmic clinical practice, repeated objective quantitative measurements of lens opacity may be necessary to document its progression and support a surgical indication. The subjective methods of evaluating the opacification of the lens have limitations, in particular due to the lack of reproducibility between observers. Thus, innovative objective techniques with precise and reproducible cataract classification results have been developed, such as the Objective Scatter Index (OSI) on the Optical Quality Analysis System (OQAS), Visiometrics SL in 2010 and, more recently, Average Lens Density (ALD) on the IOLMaster® 700 device. Cataract is diagnosed as mature when the OSI is ≥ 2 and / or when the ALD is ≥ 74 pixel units. Vitrectomy is a surgery of the posterior segment of the eye indicated for retinal detachment, epimacular membranes, macular holes, vitreous hemorrhage. The incidence of post-vitrectomy cataract varies among studies, and the methodology is often retrospective. Age has already been identified as a risk factor for progression since in a study of 28 eyes of patients under 50 years old, only 7% developed cataracts secondarily, compared to 79% in the 'over 50' group. To date, there is no prospective study describing the progression kinetics of lens opacification according to precise and reproducible quantitative objective criteria in patients treated by vitrectomy. It also involves confirming the age and preoperative lens status as a risk factor for postoperative cataract progression.
Optimizing Refractive Results and Patient Satisfaction After Cataract Surgery
CataractCataract surgery is the most common eye surgery in the world. If the patient with cataract uses spectacles and both patient and surgeon find it beneficial, it is possible to compensate for the spectacles during surgery and thereby obtain a spectacle-free distance vision or spectacle-free near vision. Becoming spectacle free increases quality of life substantially and is one of the primary wishes in cataract patients. Socioeconomically, spectacle free life is beneficial as it reduces fall tendency in the elderly population. Multifocal lenses warrant the possibility of obtaining a spectacle free vision at near, intermediate and distance. It is also possible to obtain spectacle free distance and near vision or distance and intermediate vision by using traditional artificial monofocal lenses but making one eye spectacle free for distance and the other eye spectacle free for near or intermediate vision. Currently, it is not know which procedure is most beneficial for cataract patients. In a recent PhD, the investigators developed a method, Aniseikonia Tolerance Range (ATR), that can assess how much refractive change a patient can endure without impairing stereopsis. The results demonstrated large variation in the tolerance of image difference. This method can be a future tool to assess whether a patient can tolerate the refraction that is considered most beneficial to the patient. The knowledge is important as it can help avoid improper lens choice in cataract surgery and thereby avoid stereopsis problems.
The Evaluation of Balanced Salt Solution During Cataract Surgery
Fuchs DystrophyCataractThis study aims to identify if the use of BSS PLUS® Sterile Intraocular Irrigating Solution as an irrigation solution leads to improved corneal outcomes vs BSS® Sterile Irrigating Solution in more compromised corneas.
Transdermal Microneedle Lignocaine Delivery Versus EMLA Patch for Topical Analgesia Before Venepuncture...
GlaucomaCataractMicroneedle (MN) is a mimic of a hypodermic needle, composed of hundreds of micron-sized, out-of-plane protrusions, typically arranged in arrays on a patch that can be applied onto the skin. MN can be fabricated from a variety of materials, preferably biocompatible polymers. Maltose, a natural carbohydrate, is a safe and biocompatible product that can be fabricated into MNs that are biodegradable and soluble within several minutes. Besides, local anaesthetic agents such as lignocaine can be impregnated within the MN matrix, facilitating its transdermal delivery more efficiently which results in enhanced efficacy. So far, maltose MN efficacy in enhancing the transdermal drug delivery (TDD) of lignocaine and thus reducing the pain experienced by healthy patients requiring intravenous cannulation prior to routine eye surgeries (phacoemulsification, trabeculectomy etc) has not been extensively studied. Hence, the objectives of this research are: 1) To evaluate the safety profile of lignocaine-embedded microneedle patch as a means of pain reduction in adult patients requiring routine vein-puncturing procedures; 2) To assess the pharmacokinetic (PK) parameters of lignocaine in the systemic circulation when the transdermal lignocaine delivery is enhanced through microneedle usage; 3) To compare the efficacy of lignocaine-embedded microneedle patch with standard 5% Eutectic Mixture of Local Anesthetics (EMLA) dermal patch for pain reduction during venepuncture procedure based on mean changes in VAS scores and skin algesimeter index (pharmacodynamic (PD) study).
Comparison of the Safety and Efficacy of Ophtesis Bio 3% With a Similar 3% Sodium Hyaluronate OVD...
Bilateral CataractUnilateral CataractProspective, randomized, subject/evaluator-masked post market clinical study at up to 2 sites at Gemini eye clinic in Czech Republic. Randomization will be done by the eye surgeon. The purpose of this post market clinical trial is to compare the safety and efficacy of Ophtesis Bio 3% with a similar 3% sodium hyaluronate OVD in routine cataract surgery.
Cerebral Oxymeter and End Tidal Carbondioxide Values Under Surgical Drapes With and Without Past...
Cataract ExtractionAnesthesia2 moreToday, phacoemulsification has become the most commonly applied method in the treatment of cataract, which is considered as a public health problem. Since the eyelid margins can be a source for pathogens in phacoemulsification surgery draping after skin sterilization is applied to remove the eyelashes from the operation area. Since surgical drapes are airtight, carbon dioxide (CO2) accumulation occurs under the drape in patients under local anesthesia. During the operation, if the end tidal CO2 pressure value rises, this can lead to hyperventilation and tachycardia and also increase the intraocular pressure which is undesirable in eye surgery. In our study, in order to observe and compare undesirable conditions, regional tissue oxygenation saturation (rSO2) will be determined non-invasively with Transcutaneous Near Infrared Spectroscopy (NIRS) technology , which allows real-time monitoring. Changes in the partial pressure of carbon dioxide (PaCO2) are strongly vaso-active, resulting in changes in cerebral blood volume and hence intracranial pressure. As the optic nerve sheath is an extension of the brain dura mater, the diameter of the sheath expands in case of increased intracranial pressure. Evaluation of the optic nerve sheath with ultrasound allows us to obtain information about intracranial pressure. For optic nerve sheath diameter, measurements above 5.0 mm in adult patients are generally considered as increased intracranial pressure. COVID-19 is a global epidemic caused by SARS-CoV-2 that we are still fighting. Although it is a multisystemic disease, it is important in terms of its effects on pulmonary function and the continuity of pulmonary symptoms and findings after this disease has been overcome. In our study, End-Tidal CO2 and cerebral oximetry (NIRS) values will be determined and compared between the groups that received 2lt/min and 4lt/min nasal oxygen support during cataract surgery performed using draping under local anesthesia in patients who had COVID-19, recovered and never had. It was aimed to evaluate and compare the values of optic nerve sheath diameter increase.
LensAge to Reveal Biological Age
OphthalmologyLens Opacities1 moreAssessment of aging is central to health management. Compared to chronological age, biological age can better reflect the aging process and health status; however, an effective indicator of biological age in clinical practice is lacking. Human lens accumulates biological changes during aging and is amenable to a rapid and objective assessment. Therefore, the investigators will develop LensAge as an innovative indicator to reveal biological age based on deep learning using lens photographs.