search

Active clinical trials for "Cataract"

Results 561-570 of 1416

Comparison of SRK-T With Kane Formula for Prediction of Refractive Outcome After Phacoemulsification...

Cataract; Surgery; Phacoemulsification; Biometry; Intraocular Lens Power

Cataract is a leading cause of blindness in the world. Cataract surgery is one of the most commonly performed ocular procedures. We aim to compare the newer generation biometry formula; the Kane formula with the commonly used SRK-T formula for intraocular power calculation in uneventful phacoemulsification surgery to assess the post-operative refractive outcomes at one month post-surgery.

Completed12 enrollment criteria

Clinical Investigation of the Safety and Performance of Model 690AD and Model 690ADY Monofocal Intraocular...

CataractPseudophakia2 more

Medicontur hydrophilic posterior chamber monofocal intraocular lens (IOLs) are indicated to improve vision at far distance in adults with cataract and/or ametropia (hyperopia, myopia), secondarily to removal of the crystalline lens. The intraocular lens is intended to be surgically implanted into the eye with the purpose of restoring optical function in the aphakic eye to provide an optical system with high predictability of the precalculated dioptric power. The study will be performed partially as a retrospective study with patients enrolled who had been implanted with 690AD or 690ADY IOLs mono- or binocularly between September 2021 - March 2022. Data from five visits will be collected: Baseline preoperative (maximum 90 days prior to surgery)- retrospective IOL implantation Day 0 - retrospective Postoperative visit at Day 1 (+/- 0 days) - retrospective Postoperative visit at 1 month (+/- 2 weeks) - retrospective Postoperative visit at 12 months (+/- 3 months) - consent and prospective visit

Active28 enrollment criteria

Combined Capsular Tension Ring and IOL Implantation for Management of Cataracts

Intraocular Lens RotationCapsular Tension Ring

This study included cataract patients who underwent intraocular lens (IOL) implantation with or without capsular tension ring (CTR), which aimed to evaluate the contribution of the use of CTR in clinical visual outcomes and rotational stability of IOL after cataract surgery.

Completed8 enrollment criteria

A Randomised Evaluation of Visual Function After Bilateral Implantation of Two Types of Presbyopia-correcting...

CataractPresbyopia

Since the introduction of intraocular lenses (IOL) in the treatment of cataract, the postoperative accommodative loss of the human eye has been a trending topic. Numerous studies show a high rate of spectacle-independency after bilateral implantation of multifocal IOLs (MIOL). However, glare, halos, and reduced visual acuity under different light conditions are common complaints after MIOL implantation. Due to its unique design, the TECNIS® Symfony Extended Range of Vision ZXR00 IOL (Abbott Medical Optics, Santa Ana, USA, hereinafter referred to as Symfony IOL) is theoretically providing a continuous range of high-quality vision for far, intermediate, and near distances with the same low incidence of halos and glare associated with monofocal IOLs under different light conditions. The goal of this study is to compare the AT LISA tri 839MP IOL (Carl Zeiss Meditec AG, Jena, Germany, hereinafter referred to as AT LISA IOL) versus the Symfony IOL in terms of postoperative achieved visual acuity at different distances, patient satisfaction (e.g. spectacle-independency, QoL), and postoperative complication profile (e.g. halo's and glare) under different light conditions. So far, there are no published studies comparing both IOLs. Therefore, we will perform this randomized control trial.

Completed23 enrollment criteria

Effect of the Timing of Cataract Surgery on Complications in Patients With Bilateral Congenital...

Cataract

Congenital cataract is an important treatable cause of visual handicap in childhood throughout the world. Successful management of childhood cataract is dependent on individualized treatment strategies and rigorous postoperative supervision for adverse complication. In this trial, we aimed to compare the difference of postoperative outcome between surgical timing at age of 3 month and 6 month. Patients enrolled into the study will be followed for two year and will have study visits at 1 day, 1 week, 1 month, 3 month, 6 month, 9 month, 12 month, 18month and 24month postoperatively.

Completed7 enrollment criteria

Multifocal Intraocular Lens x Monovision x Hybrid Monovision After Bilateral Cataract Surgery

CataractPresbyopia

To compare refractive outcomes and patient's visual quality after bilateral cataract surgery when implanting multifocal intraocular lens, monofocal with monovision or hybrid monovision.

Completed21 enrollment criteria

Outcome of Different IOLs in Patients With and Without Uveitis

UveitisCataract2 more

Cataract, is a clouding of the lens in the eye gradually leading to reduction of the visual acuity. In most cases it can be managed with surgery, removing the own lens and replacing it with an artificial lens, intraocular lens (IOL). These lenses are made in different materials with different properties. Uveitis refers to an inflammation in the iris, ciliary body and choroid. Patients with this disease have an increased risk of developing cataract due to the inflammation itself and treatment with steroids. They also have an increased risk of complications during surgery and postoperatively. In this group the selection of IOL might be of greater importance. The aim of this prospective randomized controlled study is to compare the outcome of hydrophobic and hydrophilic intraocular lenses in patients with and without uveitis

Completed7 enrollment criteria

Symfony Toric Intraocular Lens Visual Outcomes

Cataract BilateralAstigmatism Bilateral

In July 2016, the FDA approved an extended depth of focus (EDOF) IOL (Tecnis Symfony, Abbott Medical Optics) helping to improve the sharpness of vision at near, intermediate and far distances reducing the need of glasses after cataract surgery. It is available in both a non-toric version and a toric version for patients with astigmatism. The difference between this lens and the multifocal (MIOL) counterpart is that the EDOF, similarly to a monofocal IOL, has one focal point (elongated in the EDOF) while the multifocals have 2 focal points; therefore, having less of a halo and glare problem. Pivotal trial results where Symfony was compared to a monofocal IOL showed similar uncorrected distance visual acuity (UCDVA), better intermediate (77% vs. 34% 20/25 uncorrected intermediate visual acuity - UCIVA) and near vision (Symfony patients were able to read two additional, progressively smaller lines compared to the monofocal IOL).A One potential disadvantage of the EDOF IOL compared to a MIOL is the visual performance at near.B One option to deal with this potential shortcoming is to set the non-dominant eye for a small residual myopic error (-0.50 D)C what is referred to as nano-vision or mini mono-vision.

Completed24 enrollment criteria

Comparison of Visual Outcomes After Implantation of the POD AY GF F (PhysIOL) and the POD AY 26P...

CataractLens Opacity

The study is a prospective randomised controlled study. The patients get monolateral IOL implantation of POD F GF and POD F in the contralateral eye. Both IOLs are trifocal IOLs consisting of the same optical design. The difference between the IOLs is the material (hydrophilic and hydrophobic). To decide which eye receives POD F and which eye receives POD F GF, a randomization table will be provided to the principle investigator.

Completed14 enrollment criteria

Effect of the Color of the Intra-eye Implant in the Cataract Surgery on the Sleep

Cataract

The cataract surgery (550 000 operations per year in France) is to replace the cloudy lens with a refractive implant. Two colors of implants are available: white implants, filtering out ultraviolet and yellow implants, filtering and more blue light. No clinical data are available to assert the superiority of an implant according to its color and the choice is made according to the preference of the surgeon and / or "markets". It is established in humans that blue light has an important role on the secretion of melanopsin, a key mediator of the circadian cycle. This "clock" regulates most neuroendocrine functions in the nycthémère (sleep, mood, temperature, cortisol, ..). The question of the impact of these neuro endocrine functions of the installation of a blue light filter into the eyes of patients operated thus arises.

Completed5 enrollment criteria
1...565758...142

Need Help? Contact our team!


We'll reach out to this number within 24 hrs