Use of Nanoparticle Paclitaxel (ABI-007) for the Prevention of In-Stent Restenosis
Coronary RestenosisThe purpose of this study was to investigate the use of systemic intracoronary administration of albumin-bound paclitaxel, ABI-007, for the prevention and reduction of restenosis following de novo stenting or following angioplasty for in-stent restenosis.
Treatment of Coronary In-stent Restenosis (ISR) by a Sirolimus Coated or a Paclitaxel Coated Balloon...
Coronary RestenosisTreatment of coronary in-stent restenosis (ISR) by a sirolimus coated SEQUENT® SCB RAPID EXCHANGE PTCA balloon catheter or a paclitaxel coated SEQUENT® PLEASE PTCA balloon catheter
DUrable Polymer-based STent CHallenge of Promus Element Versus ReSolute Integrity in an All Comers...
Acute Coronary SyndromeAngina Pectoris6 moreThe introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity but there are further demands on DES performance. Such demands are an optimized performance in very challenging coronary lesions; third generation DES were developed in an effort to further improve DES performance in such challenging lesions. Two CE-certified third generation DES (Resolute Integrity and Promus Element stents) are currently available; there are no data that indicate an advantage of one of these DES over the other.
Clinical Performance of the Pantera Lux Balloon Versus the Orsiro Stent in Patients With In-stent...
Coronary Artery DiseaseCoronary RestenosisTo determine in a randomized controlled trial (RCT) whether percutaneous coronary intervention - in patients with in-stent restenosis in either bare metal stents or drug eluting stents - with the Pantera Lux balloon is angiographically non-inferior to percutaneous intervention with the Orsiro stent 6 months post-procedure.
Concordance Between FFR and iFR for the Assessment of Intermediate Lesions in the Left Main Coronary...
Coronary Artery DiseaseLeft Main Coronary Artery Stenosis3 moreThe assessment of Left Main Coronary Artery (LMCA) lesions by means of coronary angiography renders serious limitations. Studies with a limited number of patients have shown that a value of FFR (Fractional Flow Reserve) above 0.80 identify a low risk of events in case of not performing revascularization in patients with intermediate stenosis in the LMCA. Although iFR (Instant wave Free Ratio) has recently been found equivalent to FFR The demonstration of the prognostic utility of iFR in patients with LMCA intermediate lesions could have an important clinical impact and justify its systematic use for the treatment decision in these high-risk patients.
SPIRIT II: A Clinical Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System
Coronary DiseaseCoronary Artery Disease1 moreProspective, randomized, active-control, single blind, parallel two-arm multi-center clinical trial comparing XIENCE V® Everolimus Eluting Coronary Stent System to the approved commercially available active control TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent System. TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent System is manufactured by Boston Scientific.
Clinical Evaluation of Patients With Everolimus-eluting Stent Xience V® Implanted in the Treatment...
Coronary RestenosisInterventional, prospective, non-randomized, non-comparative, open and multicentric study of patients with everolimus-eluting stent " Xience V® " implanted in the treatment of restenosis in non-coated metallic stent (BMS in-stent restenosis) during a 2 year clinical follow-up period.
Resveratrol Excipient Paclitaxel Coated Balloon for Coronary Treatment
In-stent Coronary Artery RestenosisCoronary Artery Restenosis1 moreThe objective of this study is to establish reasonable assurance of safety and effectiveness to support an FDA premarket approval (PMA) application for the SeQuent® Please ReX™ Drug Coated PTCA Balloon Catheter as indicated.
Safety and Efficacy of the ZoMaxx™ Drug-Eluting Stent System in Coronary Arteries
Coronary DiseaseCoronary Artery Disease1 moreThe purpose of this study is to demonstrate the safety and efficacy of the ZoMaxx drug-eluting stent in patients with blockage of native coronary arteries. The study is designed to demonstrate non-inferiority to the TAXUS Express2 Paclitaxel-Eluting Stent that has proven superior to bare metal stents and is a recognized standard of care.
The Effects of Bindarit in Preventing Stent Restenosis
Coronary RestenosisThe main study objective is to assess the efficacy and safety of different bindarit dosages compared to placebo in preventing restenosis, in patients submitted to coronary stenting and using a bare metal stent (Vision BMS, by Abbott).