Active clinical trials for "Hypoxia"

Results 511-520 of 998

SpO2 Accuracy Comparison of Smart Sock V. 2 SpO2 to Arterial Blood CO-Oximetry

Hypoxia

Pulse oximetry monitoring is considered a standard physiological measurement and is used by clinicians in everyday situations to estimate arterial oxygen saturation. There are two devices used in this investigational study: BabySat v.1.0 and Owlet Baby Care, Inc. Smart SockTM 2 (currently available over-the-counter), with specific emphasis on its pulse oximetry accuracy. The BabySat and Smart SockTM 2 are non-invasive home care devices for use with infants. The purpose of this study was to validate the SpO2 accuracy of BabySat v1.0 and Owlet Smart SockTM 2, OSS v1.1 sensors pulse oximetry, during non-motion conditions over the range of 70-100% SaO2 as compared to arterial blood samples assessed by CO-Oximetry.

Completed12 enrollment criteria

High-flow Nasal Cannula Oxygenation Decrease Hypoxia in Gastroscopy Sedated by Propofol

HypoxiaGastric Cancer2 more

Hypoxia is the most common adverse events during sedated gastroscopy. In present study, high-flow nasal cannula oxygenation will be utilized in order to reduce the hypoxia. At the same time the feasibility and safety will be evaluated.

Completed16 enrollment criteria

The Effectivity of End-tidal CO2 and Oxygen Reserve Index (ORI) Monitoring in Sedation

HypoxemiaProcedural Sedation2 more

Endoscopic procedures are commonly performed using sedation. As drug-induced respiratory depression is a major cause of sedation-related morbidity, pulse oximetry has been established as standart practice . However SpO2 does not completely reflect ventilation. Capnography is an additional monitoring parameter which demonstrates respiration activity breath by breath. Unfortunately, in the state of moderate or deep sedation during diagnostic or therapeutic procedures (e.g.ERCP or colonoscopies), regular breathing is often disturbed by moving, squeezing, coughing or changes between nose and mouth ventilation causing leakage and therefore artifacts or misinterpretation of data acquired with ETCO2. These problems often restrict the use of side-stream capnography in clinical practice, although the American Society of Anesthesiologists have suggested in their guidelines that extended monitoring with capnography 'should be considered'in deep sedation. The oxygen reserve index (ORI) is a new feature of multiple wavelength pulse oximetry that provides real-time visibility to oxygenation status in the moderate hyperoxic range (PaO2 of approximately 100-200 mm Hg). The ORI is an "index" with a unit-less scale between 0.00 and 1.00 that can be trended and has optional alarms to notify clinicians of changes in a patient's oxygen status. When utilized in conjunction with SpO2 monitoring the ORI may extend the visibility of a patient's oxygen status into ranges previously unmonitored in this fashion. The ORI may make pre-oxygenation visible, may provide early warning when oxygenation deteriorates, and may facilitate a more precise setting of the required FiO2 level. In this study we aimed to show effectivity of capnography and ORİ monitoring to avoid respiratory events and hypoxia in sedated endoscopic patients. In this study we targeted totally 300 sedated endoscopy patients. Patients will randomize to two groups. In Group I anaesthesiologis will be able to use all the monitoring, where as in Group II will be blinded for ORİ. We will apply pre-oxygenation to obtain long safe apnea time. Approximately 5 min pre-oxygenation (5L/min via nasal cannula) will be used to reach steady state in oxygen reserve. We defined hypoxemia ; SpO2<95% and severe hypoxemia SpO2≤90%, hypoventilation; rise10 mmHg in ETCO2 compare to baseline, ETCO2≤30 mmHg and flat capnography.

Completed2 enrollment criteria

Comparing Inpatient COVID-19 Outcomes in 2 Different PT Dosing Groups

COVID-19Cardiopulmonary Disease4 more

The objective of this study is to compare the effects of twice-a-day 15-minute sessions of inpatient physical therapy (PT) to the standard daily 30 minute sessions. The patient outcomes that will be evaluated will be length of stay, change in functional status, and disposition (home/acute rehab vs. subacute/LTAC/death) in patients admitted with COVID-19.

Withdrawn7 enrollment criteria

Oxygen Reserve Index in Airway Surgery in Children

Hypoxemia During Surgery

This study aimed to identify the effect of oxygen reserve index monitoring on the occurrence of oxygen desaturation (<90%) in pediatric patients undergoing airway surgery.

Completed3 enrollment criteria

Accuracy of Pulse Oximeter With Profound Hypoxia

Hypoxia

Clinical evaluation of the accuracy of SpO2 measurements with the ANNE Limb Sensor compared to blood gas analysis in healthy, adult subjects. Hypoxia is induced in patients to different and stable levels of SaO2 over the range of 70-100%.

Completed19 enrollment criteria

Effect of Intermittent Hypoxia on Ischemia-reperfusion Injury in Healthy Individuals

Intermittent Hypoxia

The objective of the present study is to determine whether intermittent hypoxia protects against ischemia-reperfusion injury in young and older healthy individuals. The investigators hypothesize that intermittent hypoxia will attenuate the reduction in flow-mediated dilation following ischemia-reperfusion injury.

Completed7 enrollment criteria

Preventing Hypoxemia With Manual Ventilation During Endotracheal Intubation (PreVent) Trial

Respiratory FailureRespiratory Failure With Hypoxia1 more

Complications are common during endotracheal intubation of critically ill adults. Manual ventilation between induction and intubation ("bag-valve-mask" ventilation) has been proposed as a means of preventing hypoxemia, the most common complication of intubation outside the operating room. Safety and efficacy data, however, are lacking. PreVent is a randomized trial comparing manual ventilation between induction and laryngoscopy to no manual ventilation between induction an laryngoscopy during endotracheal intubation of critically ill adults. The primary efficacy endpoint will be the lowest arterial oxygen saturation. The primary safety endpoints will be the lowest oxygen saturation, highest fraction of inspired oxygen, and highest positive end-expiratory pressure in the 24 hours after the procedure.

Completed9 enrollment criteria

Cerebral Regional Tissue Oxygen Saturation to Guide Oxygen Delivery in Preterm Neonates During Immediate...

Preterm InfantBrain Injuries1 more

The aim of the COSGOD Phase III trial is to examine, if it is possible to increase survival without cerebral injury in preterm neonates <32 weeks of gestation by monitoring the cerebral tissue oxygen saturation in addition to routine monitoring of arterial oxygen saturation and heart rate and specified clinical treatment guidelines during immediate transition period after birth (the first 15 minutes).

Completed6 enrollment criteria

The Effect of Prolonged Inspiratory Time on Pulmonary Mechanics in Obese Patients

Hypoxia

The area of aesthesia-induced atelectasis is much larger in the obese compared with the non-obese, but there may also be more airway closure and impaired matching of ventilation and lung blood flow. When an anesthetized patient is turned to the prone position, dynamic compliance (Cdyn) decreases and peak airway pressure increases unless the abdomen hangs freely to prevent the abdominal viscera from compromising the diaphragm movement. Although the Wilson frame is designed to allow the abdomen to hang, it partially compresses the anterior abdominal wall and therefore does not allow the abdomen to hang completely, especially in obese patients. This in turn increases peak airway pressure and decreases Cdyn, oxygenation. This study aimed to investigate the effects of a prolonged I:E ratio (i.e., 1:1) compared with the conventional I:E ratio of 1:2 on respiratory mechanics and hemodynamics during spine surgery in the prone position in obese patients. We hypothesized that, compared with an I:E ratio of 1:2, a ratio of 1:1 improve oxygenation without hemodynamic instability .

Completed5 enrollment criteria