Double-masked Study of PG324 Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension...
Open-angle GlaucomaOcular HypertensionTo evaluate ocular hypotensive efficacy and safety of PG324 Ophthalmic Solution compared to Netarsudil (AR-13324) Ophthalmic Solution and Latanoprost Ophthalmic Solution. Following completion of the Month 12 study visit procedures, subjects will be offered the opportunity to participate in a 2-month observational (i.e., non-interventional) trial extension.
Non-inferiority of PRO-122 Ophthalmic Solution vs KRYTANTEK Ofteno® in Glaucoma or Ocular Hypertension...
Primary Open Angle GlaucomaOcular HypertensionAim: To demonstrate the non-inferiority of the PRO-122 ophthalmic solution manufactured by Laboratorios Sophia S.A. de C.V. versus Krytantek Ofteno® ophthalmic solution like hypotensive therapy in subjects with primary open angle glaucoma or ocular hypertension. Study design: a multicentric, prospective, crossover (2x2), double blind clinical study. Sample size: one hundred patients with primary open angle glaucoma or ocular hypertension. Patients in the period 1: In the first sequence 30 patients will be assigned to receive the ophthalmic solution: Krytantek Ofteno ® (timolol 0.5%%/brimonidine 0.2%/dorzolamide 2%) 1 drop B.I.D. during 30 days and the second sequence 30 patients will be assigned to receive the ophthalmic solution: PRO-122 1 drop B.I.D. during 30 days in the same period. Washout period: 20 hours. Patients in the period 2: the pharmacological intervention change to the opposite therapy for 30 days
Safety and Efficacy of Anti-Oxidants and Anti-inflammatory Agents in Glaucoma and Diabetic Retinopathy...
Open-angle GlaucomaDiabetic RetinopathyThis study is a multi-armed protocol designed to evaluate the safety and efficacy of two different combinations of nutritional supplements (study drug) (Glauco-Health and Glauco-Select) chosen for their potential to protect retinal ganglion cells against oxidative stress, low-grade inflammation, and mitochondrial dysfunction in patients with open-angle glaucoma and diabetic retinopathy. Oxidative stress and retinal cellular dysfunction will be measured using a Retinal Metabolic Analyzer (RMA) in this randomized, single center, double masked study. Patients with glaucoma will be divided into three treatment arms randomized to receive either Glauco-Health, Glauco-Select, or placebo.
Safety and Efficacy Study of PG324 (Netarsudil/Latanoprost 0.02% / 0.005%) Ophthalmic Solution Compared...
Open Angle GlaucomaOcular HypertensionThe study is intended to test the effectiveness and safety of Netarsudil / Latanoprost 0.02% / 0.005% Ophthalmic Solution, relative to GANFORT® for lowering of intraocular pressure (IOP) in patients with elevated intraocular pressure
Study of Netarsudil Ophthalmic Solution in Subjects With Primary Open Angle Glaucoma (POAG) or Ocular...
Primary Open Angle Glaucoma or Ocular HypertensionTo evaluate the effect on trabecular outflow facility of Netarsudil ophthalmic solution 0.02% compared to placebo
A Phase IIb Safety and Efficacy Study of DE-126 Ophthalmic Solution in Primary Open-Angle Glaucoma...
Open-angle GlaucomaOcular HypertensionTreatment of elevated pressure in the eye (Intraocular pressure, or 'IOP') with eye drop medications has been shown to be effective in delaying or preventing the progression of glaucoma, and it is the only proven method for reducing the risk of glaucomatous visual field loss. This study is being conducted to determine how well DE-126 ophthalmic solution works (efficacy) in safely lowering IOP when dosed as topical eyedrops. This study will evaluate the safety and efficacy of four (4) concentrations of DE-126, when compared with latanoprost (0.005%) eye drops in patients with primary open-angle glaucoma or ocular hypertension. The IOP will be measured at 3 different times throughout the day, over 6 total visits during a 3-month treatment period (with up to 4 extra weeks observation if the patient must stop taking current eye drops to lower IOP). Safety assessments will be done throughout the study, including ocular signs and symptoms, vital signs, and clinical laboratory tests. While the most important time-point to measure IOP in this study and evaluate efficacy will be at the final study visit (month 3), IOP values will also be evaluated at other visits throughout the 3-month treatment period.
Efficacy and Safety of the ExPRESS Implant Versus Deep Sclerectomy in Combined Surgery
Open Angle GlaucomaOcular HypertensionThe Ex-PRESS Glaucoma Filtration Device is a small, non-valved implant that was designed to lower intraocular pressure (IOP) by shunting aqueous humor from the anterior chamber into the subconjunctival space. The implant was developed in response to the need for more straightforward, standardized and safe surgical technique than standard filtration surgery. No iridectomy and no sclerectomy is needed if an Ex-PRESS device is implanted under a partial-thickness scleral flap. This may reduce surgical time and complications when compared to a standard trabeculectomy. In some studies it has been found to be safe and effective with few complications, even in high-risk patients. No previous studies have compared filtration surgery with Ex-Press implant to deep sclerectomy.
Generic Travoprost Versus Brand Name Travoprost in Patients With Primary Open Angle Glaucoma or...
GlaucomaPrimary Open Angle1 moreThe purpose of this study is to compare the efficacy and tolerance of generic travoprost with its brand name formulation. In this open label, randomized, crossover study, the primary outcome will be intraocular pressure and the secondary outcome will be tolerance to the drops, as measured by a subjective questionnaire. Patients will be randomized to receive either brand name or generic travoprost during the first visit. At the second visit 3 weeks later, their intraocular pressure will be measured and a questionnaire will be completed on the tolerance of the medication. Patients will then receive the other formulation of travoprost. At the third and final visit, another 3 weeks later, their intraocular pressure will be measured and a questionnaire will be completed on the tolerance of the second medication.
Study of Fixed-Dose Combinations of Trabodenoson and Latanoprost in Adults With OHT or POAG
Primary Open-Angle Glaucoma (POAG)Ocular Hypertension (OHT)Phase II, randomized, double-masked study to evaluate the efficacy and tolerability of topical ocular delivery of fixed-dosed combinations of trabodenoson and latanoprost in subjects with Ocular Hypertension or Primary Open-Angle Glaucoma. All subjects who meet the study's enrollment criteria following Screening will undergo washout of all prohibited medications (if washout is needed), including their routine glaucoma medications. During the Placebo Run-In Period, placebo is applied twice daily to both eyes in all subjects. During the Treatment Period, study drug is applied to both eyes for a total of 8 weeks. Each subject will be assigned 4 weeks of AM and 4 weeks of PM dosing in a masked manner. AM vs PM dosing is masked utilizing Placebo in addition to the active drug product. During the Treatment Period, study drug (Active and Placebo) eye drop applications will occur twice daily, in the morning and in the evening. The Treatment Period will be followed by an Observation Period of approximately 7 days wherein no study eye drops are instilled. The purpose of the study is to assess the overall benefit/risk profile of binocular topical application of different doses of trabodenoson (3.0% and 6.0%) when combined with latanoprost (0.005% or 0.0025%) one drop daily (QD) for 8 weeks.
Two Second-Generation Trabecular Micro-bypass Stents to Treat Glaucoma Subjects on One Hypotensive...
Open Angle GlaucomaThis study objective is to evaluate the intraocular pressure (IOP) lowering effect of two trabecular micro-bypass stents (iStent inject) in eyes of subjects with primary open-angle glaucoma on one topical hypotensive medication