search

Active clinical trials for "Adenomatous Polyps"

Results 51-60 of 76

Ambient Lighting During Colonoscopy and Its Effect on Adenoma Detection Rate and Eye Fatigue

Colorectal Cancer ScreeningColon Adenomatous Polyp

A retrospective and prospective study to determine if the use of ambient lighting during screening colonoscopy is well tolerated and if ambient lighting will help physicians maintain adenoma detection rates while decreasing symptoms of eye strain as the day progresses.

Completed9 enrollment criteria

Phytoestrogens and Colonic Adenomatous Polyps

Intestinal Polyps

INTRODUCTION: The data obtained by experimental studies about the influence of phytoestrogens on colorectal cancer (CRC) have been very promising. On the other hand, clinical trials have produced conflicting results. The literature suggests that some subclasses of phytoestrogens may have protective effects against CRC and colon adenomas, but most of these results come from population studies based on the dietary intake of phytoestrogens. On these premises, it is possible to hypothesize that the variability of the data reported in the literature may be due to the fact that the real absorption of phytoestrogens (by assessing their concentration in the serum or urine) and/or the ability of the single individual of producing equol was not evaluated. PURPOSE: In the present study, the association between the phytoestrogens intake and the prevalence of colon adenomas was evaluated not only on the basis of the simply dietary intake but also on the measurement their intestinal absorption. Moreover, a specific evaluation of equol production by the intestinal flora was performed. Finally, intestinal bacteria involved in equol production were evaluated.

Completed9 enrollment criteria

A Comparison of the Resection Rate of Cold Snare Polypectomy for Large (10-15 mm) and Small (5-9...

Adenomatous Polyps

Colorectal cancer remains the third most common cause of death from cancer worldwide. Colonoscopy allows removal of adenomatous polyps is the best colorectal cancer screening, according to the adenoma-carcinoma sequence. Recent studies have reported approximately 30% of interval cancer may be incomplete polyp resection. Complete polyp resection may be particularly important when implementing new methods for surveillance colonoscopies. Cold snare polypectomy (CSP) is considered to be a safer procedure for removing subcentimeter lesions than conventional hot snare polypectomy (HSP). CSP removal of polyps sized ≤5 mm have recommended by the European Society of Gastrointestinal Endoscopy guideline as the preferred technique. Previous report said that the complete resection rate of CSP for adenomatous polyps 4-9 mm in size was comparable to that of HSP, and in the foreseeable future CSP can be one of the standard techniques for 4-9 mm colorectal polyps. However, data on complete resection of colorectal polyps 1.0-1.5 mm in size is sparse. Investigators are interested in comparison of the resection rate of cold snare polypectomy for large (10-15 mm) and small (5-9 mm) colorectal polyps using CSP.

Completed10 enrollment criteria

Prophylactic Coagulation for the Prevention of Bleeding in Endoscopic Mucosal Resection of Large...

Adenomatous Polyp of Large Intestine

The hypothesis of this study is that prophylactic coagulation therapy with coagulation forceps to visible vessels within the mucosal defect for colonic Endoscopic Mucosal Resection (EMR) will reduce the rate of delayed bleeding when compared with current established standard EMR technique.

Completed10 enrollment criteria

Calcium/Vitamin D, Biomarkers & Colon Polyp Prevention

Colorectal Adenomatous Polyps

The study team has developed a set of biomarkers of risk for colon cancer; this study tests 1) whether or not calcium and/or vitamin D supplementation can favorably affect these biomarkers in persons who are at higher than average risk for colon cancer (ie, have already undergone the removal of colon growths, called adenomatous polyps, which are known to be precursors to developing colon cancer), and 2) whether effects on the biomarkers predict who will get new colon polyps or not.

Completed26 enrollment criteria

Computer Aided Detection of Polyps During Colonoscopy Procedures

Colo-rectal CancerPolyp of Colon1 more

The focus of the study is to evaluate impact on Adenomas Per Colonoscopy (APC) with a Computer Aided Detection (CAD) software assisting the gastroenterologist during a colonoscopy procedure.

Completed5 enrollment criteria

Managing Colorectal Cancer Prevention Procedure Wait Lists During the COVID-19 Pandemic

Adenomatous Polyps

The main objective of this study is to offer and evaluate an interim triage approach for patients waiting for surveillance colonoscopies. This will reduce the waiting period and the psychological stressors for our patients and from a scientific point of view allow us to compare the yield of findings for each approach.

Withdrawn16 enrollment criteria

A Comparison of the Resection Rate for Cold and Hot Snare Polypectomy for 5-15 mm Colorectal Polyps...

Adenomatous Polyps

In 2015, there were approximately 1.7 million new cases of colorectal cancer(CRC), and the deaths was close to 832,000. CRC has become the third most common malignant tumor in the world and the second leading cause of cancer death. This is mainly because adenomatous polyps can be transformed into cancer through adenoma-cancer sequences. Screening for CRC has been shown to prevent CRC and related deaths, especially colonoscopy and endoscopic resection of adenomatous polyps. Currently, the main methods of resection for polyps below 20 mm include hot snare polypectomy (HSP) and cold snare polypectomy (CSP). Due to the use of electrocautery, HSP has been shown to cause damage to the deep submucosa, the muscularis propria and submucosal arteries, resulting in postoperative bleeding, perforation and other adverse events. Compared with HSP, the mechanical cutting method is called CSP without electrocautery. Due to the short operation time and low incidence of adverse events, especially after polypectomy, it has caused more and more attention of endoscopists. The removal of 5 mm polyps from CSP has been recommended as the preferred technique by the European Society of Gastrointestinal Endoscopy(ESGE) Guidelines. A recent multicenter, prospective study in Japan recommended CSP as the standard treatment for excision of 4-9mm polyps. However, the average diameter of polyps in this study was 5.4 mm, which was not sufficient for the safety of CSP in polyps above 5 mm. In addition, there are few prospective studies of CSP complete removal of colorectal polyps 10-15 mm. More importantly, the report pointed out that 10% of 5 to 20 mm polyps were not completely removed, and some studies have shown that the cut polyp specimens are not sufficient for adequate pathological evaluation, which the researchers do not fully recognize. In this study, the investigators were interested in comparing the complete resection rates of large (10 -15 mm) and small (4-9 mm) colorectal polyps with CSP and HSP and improved methods for evaluating complete resection.

Unknown status10 enrollment criteria

Development of a Computer-aided Polypectomy Decision Support

Adenomatous Polyps

Quality components of colonoscopy include the detection and complete removal of colorectal polyps, which are precursors to CRC. However, endoscopic ablation may be incomplete, posing a risk for the development of "interval cancers". The investigators propose to develop a solution based on artificial intelligence (AI) (CADp computer-aided decision support polypectomy) to solve this problem.This research project aims to develop CADp, a computer decision support solution (CDS) for the ablation of colorectal polyps from 1 to 20 mm.

Withdrawn9 enrollment criteria

Multitarget Stool FIT-DNA Study for Colorectal Cancer Early Screening in China

Colorectal CancerAdenomatous Polyps2 more

The primary objective is to determine the diagnostic sensitivity and specificity of the newly developed multitarget FIT-DNA Colorectal Cancer (CRC) screening test (ColoClear) for detecting advanced neoplasia (including colorectal cancer and advanced adenomas) in high risk patients, using colonoscopy as the reference method. The secondary objective is to compare the screening performance of the multitarget FIT-DNA test with commercially available FIT (Fecal Immunochemical Test) assay in detecting advanced neoplasia.

Completed16 enrollment criteria
1...5678

Need Help? Contact our team!


We'll reach out to this number within 24 hrs