
Evaluation of EverLift in the Performance of Polypectomy for Polyps 4-9mm
Colo-rectal CancerPolyp of Colon1 moreThe focus of the study is to evaluate impact of submucosal injection of EverLift in achieving complete resection during polypectomy of polyps 4-9mm during colonoscopy.

BowelScope: Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities
Colorectal NeoplasmsColonic Polyp14 moreThis study aims to assess the effect, if any, on the adenoma detection rate of BowelScope bowel cancer screening flexible sigmoidoscopies by using the Endocuff Vision device.

Adenoma Detection Rate Using AI System in China
Colorectal NeoplasmsColonic Polyp1 moreThe primary aim of this study is - to explore the usefulness of Artificial Intelligence system in colonoscopy on adenoma detection rate (ADR). Other aims include to explore the data below when Artificial Intelligence is used. Mean adenomas detected per procedure, MAP Proximal Adenoma detection rate, pADR Polyp detection rate, PDR Proximal polyp detection rate, pPDR Mean polyps detected per procedure, MPP Withdrawal time, WT Cecal intubation rate, CIR Cecal intubation time, CIT

Evaluation of Reduced-volume PEG Bowel Preparation Administered the Same Day of Colonoscopy
Colonic PolypsCancer Colon1 moreThe conventional total dose of 4 L of polyethylene glycol (PEG) given the day before the procedure is safe and effective. It has been the standard cleansing regimen for the last 25 years. To overcome the difficulty in completing the bowel preparation due to large volume and/or taste, reduced-volume (mixed) bowel preparation of bisacodyl and 2 L of PEG have been shown to provide adequate colon cleansing and better tolerability. LoVol-esse is a reduced-volume PEG-based bowel preparation to be used in combination with bisacodyl and designed to improve patient tolerability and attitude toward bowel cleansing prior to colonoscopy thanks to the reduced volume and improved taste. The present study is intended to compare the new dosing regimen of the bowel lavage solution given the same day compared with standard PEG formulation (SELG 1000) given the day before colonoscopy.

Clinical Study of Real Time Colorectal Polyp Diagnosis During Colonoscopy - the VALID Colonoscopy...
Colorectal NeoplasmColonic PolypsThe investigators hypothesize that high definition colonoscopy with close focus narrow band imaging features has a high diagnostic accuracy for colorectal polyp histology, and can replace formal pathologic assessment in cases of high diagnostic confidence.

Comparative Study of Postprocessing Imaging Systems for Diminutive Colonic Polyps
Diminutive Colon PolypAdenomatous Polyp2 moreSeveral novel imaging technologies are currently used for detection and differentiation of colonic polyps during colonoscopy, such as NBI (Olympus), FICE (Fujinon), and i-Scan (Pentax). Several previous studies have indicated that NBI without magnification can be useful for real-time differentiation of diminutive colonic neoplasias. To date, however, there are no studies comparing NBI with other imaging systems (FICE or i-Scan) for differentiation of diminutive colonic polyps. The study objectives are to compare the diagnostic efficacy of NBI with that of i-Scan in real-time prediction of diminutive colonic polyps. In this prospective pilot study, diminutive colonic polyps detected during colonoscopy will be observed with conventional colonoscopy, thereafter will be observed with new imaging systems. Sensitivity, specificity, and diagnostic accuracy of both NBI and i-Scan will be assessed by reference to histological results obtained by endoscopic biopsy or polypectomy.

Clip Placement Following Colonic Endoscopic Mucosal Resection (EMR)
PolypColonic1 moreStudy design: A national, multi-center, patient-blinded, randomized clinical trial. Study population: Patients undergoing EMR with a moderate to severe risk (right sided colon, ≥2cm) of developing Delayed Bleeding (DB). Intervention: PC will be compared to standard care (no PC). Main study endpoints: Primary endpoint is the incidence of DB. Secondary endpoints are cost-effectiveness, quality of life and (severe) adverse events related to PC, adenoma recurrence and risk factors for DB.

Intraluminal Peppermint Oil and Adenoma Detection Rate in Screening Colonoscopy
Colonic PolypThis is a prospective randomized placebo-controlled trial to evaluate the efficacy of peppermint oil spraying into the colonic lumen through the scope channel during screening colonoscopy. The primary outcome is to compare the colonic peristalsis between peppermint oil and placebo. The secondary outcomes compare the procedural time, polyp detection rate, adenoma detection rate, and adverse events.

Efficacy of Artificial Intelligence-assisted Colonic Polyp Detection System
Adenoma ColonThis is a randomized controlled multicenter clinical trial of computer-aided detection (CADe) system for the adjuvant diagnosis of intestinal polyps/adenomas ever conducted in a Chinese population. In addition, this study will evaluate the effect of CADe system on adenoma detection of endoscopists under fatigue.

Comparative Effectiveness of Hot Versus Cold Snare Polypectomy of Small Colorectal Polyps
Colonic PolypsColorectal Neoplasms1 moreThis study aims to investigate the comparative effectiveness between polyp removal with or without electrical current. The investigators want to include 600 polyps in the trial. It is known that polyps have the potential to develop to cancer if left in situ, but the investigators do not know the best way to remove them completely.